Loading...
HomeMy WebLinkAbout1807 LA PORTE RD O W INVOICE DATE DUE DATE INVOICE# TOTAL DUE A % e 11/15/2023 12/20/2023 2024-00000179 $150.00 v a r li r ill rrr rii a 11, Customer#: 12252 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SUBWAY -LA PORTE RD 715 Mulberry St 1807 LA PORTE RD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1807 LA PORTE RD - 10-26-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price J REINSPECTION 2 $150.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 12252 11/15/2023 12/20/2023 2024-00000179 $150.00 Less Prepayment $0.00 Total Due -* S150.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT SUBWAY,1807 LA PORTE RD,BLDG 1807 LA PORTE RD,WATERLOO IA 50702 DETAILS Inspection Date: 10/26/2023 I Inspection Type:Annual Inspection(1Yr) ; Inspection Number: 11104 I Shift: N/A ; Station: N/A Unit: N/A j Lead Inspector:Mike Heerkes ; Other Inspectors: N/A ; Fee:$150.00 STATUS CODE DESCRIPTION FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:Mike Heerkes-Comments:repair exit light Location: Main exit FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector: Mike Heerkes-Comments:Repair exit light Location:South Exit FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:Mike Heerkes-Comments:Repair exit light. Location: Rear exit-employee area Printed on 10/30/2023 @ 13:33 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers conditionsOpen electrical shall be provided for all switch and electrical outlet boxes. terminations. Inspector:Mike Heerkes-Comments:Replace missing breaker or install listed blank cover. — ' Location: Electrical Panel in back room Ms . L 1 a ca i .;?' -D � . r t \ s .",', r E Printed on 10/30/2023 @ 13:33 Page 2 of 4 STATUS CODE DESCRIPTION FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be ~ 11_jln providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space. Exceptions: 1.Where other dimensions are 1 I [ \ required or allowed by NFPA 70.2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). r e. Inspector: Mike Heerkes-Comments:remove obstructions and maintain proper clearance to electrical panel at all times. Location: Electric Panel back room Nv GENERAL NOTES Mike Heerkes-09/26/2023 @ 10:47 annual inspection fee$80 Mike Heerkes-09/26/2023 @ 10:47 No progress has been made on correcting violations.Re-inspection fee$100.00 Mike Heerkes-10/30/2023 @ 13:28 Still no progress on marked deficiencies. Desk was moved from under electrical panel, however other materials have been placed in the area of panel. Re-inspection fee$ 150.00 REINSPECTION DATE 11/27/2023 Printed on 10/30/2023 @ 13:33 Page 3 of 4 CONTACT SIGNATURE Kaitlyn Owen P A/� Signed on:10/30/2023 @ 13:30 C�'� INSPECTOR SIGNATURE Mike Heerkes Signed on:10/30/2023 @ 13:31 //Ai QUESTIONS ABOUT YOUR INSPECTION? Mike Heerkes mike.heerkes@waterloo-ia.org 3192914319 Printed on 10/30/2023 @ 13:33 Page 4 of 4