HomeMy WebLinkAbout2935 LOGAN AVE w A r INVOICE DATE DUE DATE INVOICE# TOTAL DUE
11/15/2023 12/20/2023 2024-00000180 $200.00
's ihrAfTf elf/Zffs'tff>Js •
•
1`... ."r` _ 0
Customer#: 15560 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
DOLLAR GENERAL 715 Mulberry St
100 MISSION RIDGE WATERLOO, IA 50703
GOODLETTSVILLE, TN 37072
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL INSPECTION -2935 LOGAN AVE- 10-27-23 FOR BILLING INQUIRY: (319)291-4323
Description I Total Price j
REINSPECTION 3 $200.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
15560 11/15/2023 12/20/2023 2024-00000180 $200.00
Less Prepayment $0.00
Total Due $200.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE
fitOt1
INSPECTION REPORT
DOLLAR GENERAL#4698,2935 LOGAN AVE,BLDG 2935 LOGAN AVE,WATERLOO IA 50703
DETAILS
Inspection Date: 10/27/2023 ! Inspection Type:Annual Inspection(1Yr) j Inspection Number: 11164 I Shift: N/A Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A
STATUS CODE DESCRIPTION
FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:JEFF SIEBEL-Comments: Remove obstructions from exit paths. Maintain
clear paths throughout store.A.Stock items not allowed to be stored in exit paths on
carts.Only cart allowed in exit paths are those that are attended and being actively
unloaded.B. Remove obstruction to rear store exit.Maintain a clear 36"pathway and
all storage must be stable.
Location:aisles in store.
Printed on 10/30/2023 @ 08:40
Page 1 of 5
STATUS CODE DESCRIPTION
FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically.
Printed on 10/30/2023 @ 08:40
Page 2 of 5
STATUS CODE DESCRIPTION
Inspector:JEFF SIEBEL-Comments:fire doors must completely self close and latch.
repair latch. If replaced must match exactly current latch as it is part of a listed fire
door.On 4/21/23 all hardware removed and fire rating tags were completely painted
fisl,." over disqualifying the listing of the assembly.Clean labels,install listed hardware to
ll � meet requirements of the listed fire door and fire wall.Door must completely self-
`' --- close and latch. Remove kickstands(hold open devices)or have reviewed by an
• architect on requirements of fire wall and submit report to building official for review.
On 8/21/23 panic hardware is installed.Obtain permit and provide documentation
that door hardware meets fire rating of door assembly.Clean paint from UL fire
,, rating labels.
Location: Not Provided
ff/77 0—
Y
r � �
'� er�R
3�yea w ..�<
fir+
a �
5,1
Printed on 10/30/2023 @ 08:40
Page 3 of 5
GENERAL NOTES
JEFF SIEBEL-10/30/2023 @ 08:36 Re-inspection fee$200
JEFF SIEBEL-10/05/2023 @ 09:43
JEFF SIEBEL-10/05/2023 @ 09:43
JEFF SIEBEL-10/05/2023 @ 09:43
JEFF SIEBEL-10/05/2023 @ 09:43
JEFF SIEBEL-10/30/2023 @ 08:35
JEFF SIEBEL-10/30/2023 @ 08:35
JEFF SIEBEL-10/30/2023 @ 08:36
REINSPECTION DATE
11/21/2023
CONTACT SIGNATURE
Adam Blackburn-District Manager (2
Signed on: 10/30/2023 @ 08:37
7-1(°/ '
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:10/30/2023 @ 08:39
Printed on 10/30/2023 @ 08:40
Page 4 of 5
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
ieff.Siebel@Waterloo-ia.org
3192301224
Printed on 10/30/2023 @ 08:40