Loading...
HomeMy WebLinkAbout2060 SOVIA DR WA . INVOICE DATE DUE DATE INVOICE# TOTAL DUE e 11/15/2023 12/20/2023 2024-00000185 $80.00 0 46. �S7Vlt') Customer#: 21550 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable PLANET FITNESS 715 Mulberry St 2060 SOVIA DRIVE WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-2060 SOVIA DR- 11-7-23 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 21550 11/15/2023 12/20/2023 2024-00000185 $80.00 Less Prepayment $0.00 Total Due—> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE , INSPECTION REPORT PLANET FITNESS,2060 SOVIA DR,BLDG 2060 SOVIA DR-STE 109,WATERLOO/A 50702 DETAILS Inspection Date: 11/07/2023 Inspection Type:Annual Inspection(1Yr) Inspection Number:8534 Shift: N/A ( Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A ; Fee:$80.00 STATUS CODE DESCRIPTION FAIL 102.4-Application of building The design and construction of new structures shall comply with the International code. Building Code,and any alterations,additions,changes in use or changes in structures required by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Inspector:JEFF SIEBEL-Comments:Obtain final Fire,plumbing,electrical and building inspections for remodel project. Location: Remodel FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tiles Location:utility room-water heater room Printed on 11/13/2023 @ 09:40 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile Location:women's restroom/locker room GENERAL NOTES JEFF SIEBEL-11/13/2023 @ 09:39 annual inspection$80 REINSPECTION DATE 11/27/2023 CONTACT SIGNATURE Devon Boyd �c L Signed on:11/13/2023 @ 09:38 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 11/13/2023 @ 09:38 Printed on 11/13/2023 @ 09:40 Page 2 of 3 R 1 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 11/13/2023 @ 09:40 Page 3of3