Loading...
HomeMy WebLinkAbout120 SUMNER ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE 11/15/2023 12/20/2023 2024-00000189 $80.00 U e,I�l1 j�*,�.:�,.,..�r.. 0 r t rar`r..• � i 0 =......... t3J Customer#: 23516 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CLUB LEGACY 715 Mulberry St 120 SUMNER ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 120 SUMNER ST- 11-7-23 FOR BILLING INQUIRY: (319)291-4323 [Description I Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23516 11/15/2023 12/20/2023 2024-00000189 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE4Pp,00 INSPECTION REPORT CLUB LEGACY,120 SUMNER ST,BLDG 120 SUMNER ST,WATERLOO IA 50703 4t.o. DETAILS Inspection Date: 11/07/2023 Inspection Type:Annual Inspection(1Yr) j Inspection Number:9523 Shift: N/A I Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A I Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1010.2.9-Panic and fire exit Swinging doors serving a Group H occupancy and swinging doors serving rooms or hardware. spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock other than panic hardware or fire exit hardware. Exceptions: 1.A main exit of a Group A occupancy shall be permitted to have locking devices in accordance with Section 1010.2.4, Item 2 3.2.Doors provided with panic hardware or fire exit hardware and serving a Group A or E occupancy shall be permitted to be electrically locked in accordance with Section 1010.2.12 or 1010.2.11. 3. Exit access doors serving occupied exterior areas shall be permitted to be locked in accordance with Section 1010.2.4, Item 8.4.Courtrooms shall be permitted to be locked in accordance with Section 1010.2.13, Item 3.Electrical rooms with equipment rated 1,200 amperes or more and over 6 feet(1829 mm)wide,and that contain overcurrent devices,switching devices or control devices with exit or exit access doors,shall be equipped with panic hardware or fire exit hardware.The doors shall swing in the direction of egress travel. Inspector:JEFF SIEBEL-Comments:Repair or Replace broken panic hardware in back bar area. Location: Not Provided FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:Provide currently serviced fire extinguisher mounted 4"to 5'above the floor in an accessible place.One in each bar area. Location: Not Provided Printed on 11/08/2023 @ 08:14 Page 1 of 2 STATUS CODE DESCRIPTION F AIL 906.7-Hangers and brackets. Hand-held portable fire extinguishers,not housed in cabinets,shall be installed on the hangers or brackets supplied.Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:fire extinguishers must be mounted 4"to 5' above the floor. Location: Not Provided GENERAL NOTES JEFF SIEBEL-11/08/2023 @ 08:13 annual inspection$80 REINSPECTION DATE 12/07/2023 CONTACT SIGNATURE Trice Scott Signed on: 11/08/2023 @ 08:03 2Pr/ Zt7 INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 11/08/2023 @ 08:11 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 11/08/2023 @ 08:14 Page 2 of 2