Loading...
HomeMy WebLinkAbout504 SYCAMORE ST W A T INVOICE DATE DUE DATE INVOICE# TOTAL DUE A 11/15/2023 12/20/2023 2024-00000190 $80.00 0 3 Customer#: 23251 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ARI'Z 715 Mulberry St 504 SYCAMORE ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 504 SYCAMORE ST- 10-16-23 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23251 11/15/2023 12/20/2023 2024-00000190 $80.00 Less Prepayment $0.00 Total Due— $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE 4p1ERC00 INSPECTION REPORTt f ARIZ,504 SYCAMORE ST,BLDG 504 SYCAMORE ST,WATERLOO/A 50703 DETAILS Inspection Date: 10/16/2023 I Inspection Type:Annual Inspection(1Yr) I Inspection Number:9292 ; Shift: N/A I Station: N/A j Unit: N/A j Lead Inspector:JEFF SIEBEL j Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 102.4-Application of building The design and construction of new structures shall comply with the International code. Building Code,and any alterations,additions,changes in use or changes in structures required by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Inspector:JEFF SIEBEL-Comments:Contact contractor to Obtain HVAC and electrical permits for new furnace installed in ceiling Location:front bar area FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:Replace missing ceiling or install fire sprinkler coverage above ceiling. Location:front bar area Printed on 10/17/2023 @ 09:03 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:Fire extinguishers due for annual service Location: Not Provided GENERAL NOTES JEFF SIEBEL-10/17/2023 @ 09:01 oven removed from power strip during inspection. JEFF SIEBEL-10/17/2023 @ 09:00 annual inspection fee$80 REINSPECTION DATE 11/06/2023 CONTACT SIGNATURE Helen Redding Signed on:10/17/2023 @ 08:59 (' /( V INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 10/17/2023 @ 09:00 Printed on 10/17/2023 @ 09:03 Page 2 of 3 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 10/17/2023 @ 09:03 Page 3of3