COMMERCIAL INSPECTION- 630 HILLCREST RD - 9-22-23 FOR BILLING INQUIRY: (319)291-4323
LDescription I Total Price
INSPECTION 50,000 $225.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
5689 09/28/2023 10/31/2023 2024-00000122 $235.00
Less Prepayment $0.00
Total Due $235.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
66(
WATERLOO FIRE RESCUE 44PtER,00
INSPECTION REPORT f
HOOVER MIDDLE SCHOOL,630 HILLCREST RD,BLDG 630 HILLCREST RD,WATERLOO IA 50701
DETAILS
Inspection Date:09/22/2023 ; Inspection Type:Biennial Inspection(2yrs) ; Inspection Number:6756 Shift: N/A Station: N/A
Unit: N/A ! Lead Inspector:JEREMIAH VANDYKE Other Inspectors:BROCK WELIVER I Fee:$235.00
STATUS CODE DESCRIPTION
FAIL 603.5.2-Application and Relocatable power taps and current taps shall be directly connected to a
usePower supply. permanently installed receptacle. Exceptions: 1.Where approved for use in a Group A
occupancy or in a meeting room in a Group B occupancy, not more than five
relocatable power taps shall be permitted to be connected together or connected to
an extension cord for temporary use to supply power to electronic equipment.2.
Current taps and relocatable power taps shall not be required to connect directly to
a permanently installed receptacle outlet where used for 90 days or less for the
purpose of testing the performance of such devices.
Inspector:JEREMIAH VANDYKE-Comments: Powerstrip hanging under desk and
needs to be secured.
Location: Ms.Netty office.
FAIL 603.8-Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations
shall not exceed is allowed for a period not to exceed of 90 days.Temporary wiring
methods shall meet the applicable provisions of NFPA 70.Exception:Temporary
wiring for electrical power and lighting installations is allowed complying with the
applicable provisions of NFPA 70 is permitted during periods of construction,
remodeling,repair or demolition of buildings,structures,equipment or similar
activities.
Inspector:JEREMIAH VANDYKE-Comments:Decorative lights found in rooms.
Location: Rooms#111, 110,105,&115.
Printed on 09/22/2023 @ 09:50
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems
protection. used to protect joints and voids in the following locations shall be maintained.The
materials and systems shall be securely attached to or bonded to the adjacent
construction,without openings visible through the construction. 1.joints in or
between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a
horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a
horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a
nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the
intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the
intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.
Unprotected joints and voids do not need to be protected where such joints and
voids were not required to be protected when the building was originally
constructed.Where the system design number is known,the system shall be
inspected to the listing criteria and manufacturer's installation instructions.
Inspector:JEREMIAH VANDYKE-Comments:Missing ceiling tiles.
Location:Room#316,Room#107,and Romm#107 IT room.
GENERAL NOTES
JEREMIAH VANDYKE-09/22/2023 @ 09:37 Fire Drill completed 9/6/2023.
JEREMIAH VANDYKE-09/22/2023 @ 09:37 Exit and egress lights record test 9/2/2023.
JEREMIAH VANDYKE-09/22/2023 @ 09:41 Stage Curtains TXed 8/17/2020 by Harris Cleaning.
JEREMIAH VANDYKE-09/22/2023 @ 09:43 No deficiencies or past dues on Compliance Engine Website.
JEREMIAH VANDYKE-09/22/2023 @ 09:49 Re-inspection dates are automatically generated 30 days out from the initial
inspection. Normal operating hours for inspections&re-inspections are Monday-
Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on
a weekend,the re-inspection will typically be performed the following Monday or
Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier
re-inspection.*****Re inspection fees may be assessed for subsequent re-
inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent
re-inspections.-
JEREMIAH VANDYKE-09/22/2023 @ 09:49 Inspection Fee=$235.00
JEREMIAH VANDYKE-09/22/2023 @ 09:39 Fire Extinguishers serviced by Superior Fire in June 2023.
Printed on 09/22/2023 @ 09:50
Page 2 of 3
GENERAL NOTES
JEREMIAH VANDYKE-09/22/2023 @ 09:49 Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883-
1615
REINSPECTION DATE
10/22/2023
CONTACT SIGNATURE
Zach Kelly Reason for not collecting a signature: NA
INSPECTOR SIGNATURE
JEREMIAH VANDYKE
Signed on:09/22/2023 @ 09:49 V