Loading...
HomeMy WebLinkAbout630 HILLCREST RD WA r A, INVOICE DATE DUE DATE INVOICE# TOTAL DUE 09/28/2023 10/31/2023 2024-00000122 $235.00 yy /J 0 4s Customer#: 5689 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HOOVER INTERMEDIATE 715 Mulberry St 630 HILLCREST RD WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 630 HILLCREST RD - 9-22-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price INSPECTION 50,000 $225.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 5689 09/28/2023 10/31/2023 2024-00000122 $235.00 Less Prepayment $0.00 Total Due $235.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 66( WATERLOO FIRE RESCUE 44PtER,00 INSPECTION REPORT f HOOVER MIDDLE SCHOOL,630 HILLCREST RD,BLDG 630 HILLCREST RD,WATERLOO IA 50701 DETAILS Inspection Date:09/22/2023 ; Inspection Type:Biennial Inspection(2yrs) ; Inspection Number:6756 Shift: N/A Station: N/A Unit: N/A ! Lead Inspector:JEREMIAH VANDYKE Other Inspectors:BROCK WELIVER I Fee:$235.00 STATUS CODE DESCRIPTION FAIL 603.5.2-Application and Relocatable power taps and current taps shall be directly connected to a usePower supply. permanently installed receptacle. Exceptions: 1.Where approved for use in a Group A occupancy or in a meeting room in a Group B occupancy, not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2. Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Inspector:JEREMIAH VANDYKE-Comments: Powerstrip hanging under desk and needs to be secured. Location: Ms.Netty office. FAIL 603.8-Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations shall not exceed is allowed for a period not to exceed of 90 days.Temporary wiring methods shall meet the applicable provisions of NFPA 70.Exception:Temporary wiring for electrical power and lighting installations is allowed complying with the applicable provisions of NFPA 70 is permitted during periods of construction, remodeling,repair or demolition of buildings,structures,equipment or similar activities. Inspector:JEREMIAH VANDYKE-Comments:Decorative lights found in rooms. Location: Rooms#111, 110,105,&115. Printed on 09/22/2023 @ 09:50 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEREMIAH VANDYKE-Comments:Missing ceiling tiles. Location:Room#316,Room#107,and Romm#107 IT room. GENERAL NOTES JEREMIAH VANDYKE-09/22/2023 @ 09:37 Fire Drill completed 9/6/2023. JEREMIAH VANDYKE-09/22/2023 @ 09:37 Exit and egress lights record test 9/2/2023. JEREMIAH VANDYKE-09/22/2023 @ 09:41 Stage Curtains TXed 8/17/2020 by Harris Cleaning. JEREMIAH VANDYKE-09/22/2023 @ 09:43 No deficiencies or past dues on Compliance Engine Website. JEREMIAH VANDYKE-09/22/2023 @ 09:49 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.*****Re inspection fees may be assessed for subsequent re- inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-09/22/2023 @ 09:49 Inspection Fee=$235.00 JEREMIAH VANDYKE-09/22/2023 @ 09:39 Fire Extinguishers serviced by Superior Fire in June 2023. Printed on 09/22/2023 @ 09:50 Page 2 of 3 GENERAL NOTES JEREMIAH VANDYKE-09/22/2023 @ 09:49 Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883- 1615 REINSPECTION DATE 10/22/2023 CONTACT SIGNATURE Zach Kelly Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:09/22/2023 @ 09:49 V QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 09/22/2023 @ 09:50 Page 3 of 3