Loading...
HomeMy WebLinkAbout1350 KATOSKI DR 0,� W A INVOICE DATE DUE DATE INVOICE# TOTAL DUE ,� 4){ 09/28/2023 10/31/2023 2024-00000123 $235.00 � 0 { f • 0 "" 3 'IVi'N Customer#: 3608 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CENTRAL INTERMEDIATE 715 Mulberry St 1350 KATOSKI DR WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1350 KATOSKI DR- 9-19-23 FOR BILLING INQUIRY: (319)291-4323 lDescription I Total Price I INSPECTION 50,000 $225.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 3608 09/28/2023 10/31/2023 2024-00000123 $235.00 Less Prepayment $0.00 Total Due— $235.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE �ptERj�O INSPECTION REPORT CENTRAL MIDDLE SCHOOL,1350 KATOSKI DR,BLDG 1350 KATOSKI DR,WATERLOO IA 50701 4,40 DETAILS Inspection Date:09/19/2023 Inspection Type:Biennial Inspection(2yrs) i Inspection Number:6757 ; Shift: N/A Station: N/A Unit: N/A j Lead Inspector:BROCK WELIVER Other Inspectors:JEREMIAH VANDYKE Fee:$235.00 STATUS CODE DESCRIPTION FAIL 1010.1 -Doors. Means Doors in the means of egress shall comply with the requirements of Sections 1010.1.1 through 1010.3.4.Exterior exit doors shall meet also comply with the requirements of this section.Doors serving a Section 1022.2.Gates in the means of egress shall comply with the requirements of Sections 1010.4 and 1010.4.1.Turnstiles in the means of egress system shall meet comply with the requirements of this section and Section 1022.2.Doors Sections 1010.5 through 1010.5.4. Doors,gates and turnstiles provided for egress purposes in numbers greater than required by this code shall meet comply with the requirements of this section.Doors in the Means means of egress doors shall be readily distinguishable from the adjacent construction and finishes such that the doors are easily recognizable as doors. Mirrors or similar reflecting materials shall not be used on means of egress doors. Means of egress doors shall not be concealed by curtains,drapes,decorations or similar materials. Inspector: BROCK WELIVER-Comments:Exit door from class room was hidden behind a curtain to prevent students from leaving the room. Exit doors need to be available for use at anytime and must be readily distinguishable. Location:WCC 319 FAIL 1010.1.3-Door opening The force for pushing or pulling open interior swinging egress doors,other than fire force Forces to unlatch and doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force open doors. required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors,as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N). 2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm).The force to open doors shall comply with the following:1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full- open position when subjected to not more than a 15-pound(67 N)force. Inspector:BROCK WELIVER-Comments: Roof access door is very hard to open Location: Roof access by WCC 203 Printed on 09/20/2023 @ 16:38 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 603.5.3-Installation. Relocatable power tap cords shall not extend through walls,ceilings,floors,under doors or floor coverings,or be subject to environmental or physical damage. Inspector: BROCK WELIVER-Comments: Daisy chained electrical cords behind refrigerator Location:210 A FAIL 705.2.3-Hold-open devices Hold-open devices and automatic door closers,where provided,shall be maintained. and closers. During the period that such device is out of service for repairs,the door it operates shall remain in the closed position. Inspector:BROCK WELIVER-Comments:No violation-doors are wired for electronic hold open devices,there are no magnets installed on the doors-check with your installing contactor to finish placing the magnets on the doors. Location:Stairway 2nd floor WCC&Doors at top of stairs at Door 19 GENERAL NOTES BROCK WELIVER-09/20/2023 @ 15:59 Fire sprinkler:current,report is located in TCE,no deficiencies noted.*5 year sprinkler inspection is due 5/15/2024 BROCK WELIVER-09/20/2023 @ 16:09 Fire Extinguishers:current,serviced by Superior Fire Protection,June 2023 BROCK WELIVER-09/20/2023 @ 16:36 Inspection fee=$235 BROCK WELIVER-09/20/2023 @ 16:01 Fire Alarm:past due,renewal date was for 8/2/2023.Contact your alarm contractor for annual inspection/testing/maintenance.*Ongoing construction could be the cause in the delay BROCK WELIVER-09/20/2023 @ 16:07 Hood suppression:current,last serviced 8/15/2023,report is in TCE, no deficiencies noted BROCK WELIVER-09/20/2023 @ 16:07 Hood cleaning:current,last serviced 3/16/2023,report is in TCE, no deficiencies noted BROCK WELIVER-09/20/2023 @ 16:08 Private hydrants:current,last serviced 6/22/2023.Report is in TCE,no deficiencies noted. Printed on 09/20/2023 @ 16:38 Page 2 of 3 GENERAL NOTES BROCK WELIVER-09/20/2023 @ 16:29 This inspection also includes the WCC Expansion.The construction areas on the southern portion of the middle school are not included on this inspection.The gym, pool,auditorium,commons area,and kitchen were all inspected as part of the construction project prior to the start of the school year.The construction project is scheduled to be completed and turned over during winter break and will be inspected prior to the building being completed for turn over. BROCK WELIVER-09/20/2023 @ 16:36 Invoice Contact/Zach Kelly/319-404-8085 BROCK WELIVER-09/20/2023 @ 16:32 Stage Curtains: last treated 2020 NEXT INSPECTION DATE 09/19/2025 CONTACT SIGNATURE Zach Kelly Reason for not collecting a signature:Contact refused Refusal Reason:N/A INSPECTOR SIGNATURE BROCK WELIVER Signed on:09/20/2023 @ 16:37 QUESTIONS AMOUT YOUR INSPECTION? BROCK WELIVER brock.weliver@waterloo-ia.org 3192914460 Printed on 09/20/2023 @ 16:38 Page 3of3