COMMERCIAL INSPECTION- 139 E MITCHELL AVE-9-18-23 FOR BILLING INQUIRY: (319)291-4323
Description I Total Price
INSPECTION 20,000 $90.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
6751 09/28/2023 10/31/2023 2024-00000127 $100.00
Less Prepayment $0.00
Total Due—* $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
�pSERL�
WATERLOO FIRE RESCUE
INSPECTION REPORT ':0171)
ST EDWARDS SCHOOL,139 E MITCHELL AVE,BLDG 139 E MITCHELL AVE,WATERLOO IA 50702
DETAILS
Inspection Date:09/18/2023 j Inspection Type:Annual Inspection(1 Yr) I Inspection Number:8921 Shift: N/A
Station:Station 1 Fire Headquarters ; Unit: N/A I Lead Inspector:JEREMIAH VANDYKE j Other Inspectors: BROCK WELIVER
Fee:$100.00
STATUS CODE DESCRIPTION
FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:JEREMIAH VANDYKE-Comments:Chair in hallway.FM Weliver was going to
look into it.
Location: In hallway near library.
FAIL 2015 IFC-Fire alarm testing Is the fire alarm system powered,operational and displaying normal operation(no
and maintenance troubles,supervisory,or alarms)?
Inspector:JEREMIAH VANDYKE-Comments:Fire alarm panel currently in trouble
mode,they have contacted the fire alarm contractor to address.
Location: Not Provided
FAIL 603.8-Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations
shall not exceed is allowed for a period not to exceed of 90 days.Temporary wiring
methods shall meet the applicable provisions of NFPA 70.Exception:Temporary
wiring for electrical power and lighting installations is allowed complying with the
applicable provisions of NFPA 70 is permitted during periods of construction,
remodeling,repair or demolition of buildings,structures,equipment or similar
activities.
Inspector:JEREMIAH VANDYKE-Comments: Decorating lighting is to be tempory for
90 days only.Discussed with Steve that the school should have a policy of use and
making sure they are turned off at the end of the day.
Location:Christmas lights in classrooms.
GENERAL NOTES
JEREMIAH VANDYKE-09/18/2023 @ 08:00 Fire drill completed and recorded 8/15/2023.
Printed on 09/18/2023 @ 08:13
Page 1 of 3
GENERAL NOTES
JEREMIAH VANDYKE-09/18/2023 @ 08:00 Fire Extinguishers serviced by Pro Shield April 2023.
JEREMIAH VANDYKE-09/18/2023 @ 08:08 8/17/2023 S-(Annual)Fire Alarm HAWKEYE ALARM Reviewed Compliant
JEREMIAH VANDYKE-09/18/2023 @ 08:08 10/11/2022 L-(Annual)Kitchen Exhaust HARRIS CLEANING SERVICE AND AH Reviewed
Compliant
JEREMIAH VANDYKE-09/18/2023 @ 08:10 AED's must be addressed and service for maintenance.
JEREMIAH VANDYKE-09/18/2023 @ 08:11 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in
the event of an emergency at that address.Phone#319-291-2515.
JEREMIAH VANDYKE-09/18/2023 @ 08:11 Re-inspection dates are automatically generated 30 days out from the initial
inspection. Normal operating hours for inspections&re-inspections are Monday-
Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on
a weekend,the re-inspection will typically be performed the following Monday or
Tuesday. If all corrections are made before the 30 days,you can call to setup an earlier
re-inspection.*****Re inspection fees may be assessed for subsequent re-
inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent
re-inspections.-
JEREMIAH VANDYKE-09/18/2023 @ 08:11 Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-319-883-1615
JEREMIAH VANDYKE-09/18/2023 @ 08:11 Inspection Fee=$100.00
REINSPECT/ON DATE
10/18/2023
CONTACT SIGNATURE
Steve Lathrop Reason for not collecting a signature: NA
Printed on 09/18/2023 @ 08:13
Page 2 of 3
INSPECTOR SIGNATURE
JEREMIAH VANDYKE
Signed on:09/18/2023 @ 08:09
QUESTIONS ABOUT YOUR INSPECTION?
JEREMIAH VANDYKE
jeremiah.vandyke@waterloo-ia.org
No phone number available
Printed on 09/18/2023 @ 08:13
Page 3 of 3