Loading...
HomeMy WebLinkAbout118 S BARCLAY ST W A? INVOICE DATE DUE DATE INVOICE# TOTAL DUE o ., 11/01/2023 12/10/2023 2024-00000131 $80.00 ) 0 'VI'S Customer#: 23988 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SAFE CARE LEARNING CENTER 715 Mulberry St 118 S BARCLAY ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 118 S BARCLAY ST- 10-2-23 FOR BILLING INQUIRY: (319)291-4323 [Description I Total Price, INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23988 11/01/2023 12/10/2023 2024-00000131 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. r; C\ WATERLOO FIRE RESCUE pSERto INSPECTION REPORT ;h° SAFE CARE LEARNING CENTER,118 S BARCLAYST,BLDG 118 S BARCLAYST,WATERLOO IA 1 S07Q3 .2414106 DETAILS Inspection Date: 10/02/2023 ! Inspection Type:Annual Inspection(1Yr) ; Inspection Number:9431 ; Shift: N/A i Station: N/A Unit: N/A Lead Inspector:JEREMIAH VANDYKE I Other Inspectors: N/A i Fee:$80.00 STATUS CODE DESCRIPTION F !L 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEREMIAH VANDYKE-Comments:Storage,bed cots, mattresses,car seats, and coat lockers must be moved from marked exit pathways. Location:All marked exit paths. 3 C pa� {33 t a � tY t^ jfft J r 7.4 Printed on 10/02/2023 @ 16:53 Page 1 of 6 STATUSDESCRIPTION CODE • t • _ er ..E� l � FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEREMIAH VANDYKE-Comments: Egress light tested and failed. Location: Back hallway near AED. Printed on 10/02/2023 @ 16:53 Page 2 of 6 STATUS CODE DESCRIPTION FAI L 405.6-Recordkeeping. Records shall be maintained of required emergency evacuation drills and include the following information: 1.Identity of the person conducting the drill.2.Date and time of the drill.3.Notification method used.4.Employees on duty and participating. 5.Number of occupants evacuated.6.Special conditions simulated.7.Problems encountered.8.Weather conditions when occupants were evacuated.9.Time required to accomplish complete evacuation. Inspector:JEREMIAH VANDYKE-Comments:Need record of fire drills with date and time. Location: Not Provided FAIL 509.1 -Identification. Fire protection equipment shall be identified in an approved manner.Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements fire protection systems shall be identified for the use of the fire department.Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Inspector:JEREMIAH VANDYKE-Comments:Permenant Signage on door stating" Main Electrical Panel&Fire Alarm Panel"on door. Location: Front closet with fire alarm and electrical panel. FAIL 603.4-Working space and A working space of not Working space around electrical equipment shall be provided clearancesclearance. in accordance with Section 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm) in width,36 inches(914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service a . equipment is wider than 30 inches(762 mm),the minimum working space shall be mil,+■•► - not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions: 1.Where other dimensions are f required or allowed by NFPA 70.2.Access openings into attics or under-floor areas _ that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Inspector:JEREMIAH VANDYKE-Comments: Must remove storage in front of electrical -tee panel and fire alarm panel. Location: Front closet Printed on 10/02/2023 @ 16:53 Page 3 of 6 STATUS CODE DESCRIPTION FAIL 603.4.1 -Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating"ELECTRICAL ROOM"or similar approved wording.The disconnecting means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Inspector:JEREMIAH VANDYKE-Comments:Permenant Signage on door stating" Main Electrical Panel&Fire Alarm Panel"on door. / Location: Front closet. FAIL 705.2-Inspection and Opening protectives in fire-resistance-rated assemblies shall be inspected and maintenance. maintained in accordance with NFPA 80.Opening protectives in smoke barriers shall be inspected and maintained in accordance with NFPA 80 and NFPA 105.Openings in smoke partitions shall be inspected and maintained in accordance with NFPA 105. Fire doors and smoke and draft control doors shall not be blocked,obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged.Opening protectives and smoke and draft control doors shall not be modified. Inspector:JEREMIAH VANDYKE-Comments:Fire Rated Doors are not to be blocked 7. open with blocks/door stops.Must remove and keep marked fire doors shut at all times.Discussed having fire alarm contractor installing magnetic locks to hold open door. MAY require sign on doors that state"By order of Fire Marshal that doors to be closed at all times".This is REPEAT VIOLATION. Location: Both middle doors. Printed on 10/02/2023 @ 16:53 Page 4 of 6 STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10.Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEREMIAH VANDYKE-Comments:All fire extinguishers are past due and must be serviced and tagged. Location: Entire Building. GENERAL NOTES JEREMIAH VANDYKE-10/02/2023 @ 16:37 03/03/2023 S-(Annual)Fire Alarm HAWKEYE ALARM Reviewed Compliant JEREMIAH VANDYKE-10/02/2023 @ 16:49 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection.*****Re inspection fees may be assessed for subsequent re- inspections.Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-10/02/2023 @ 16:49 Inspection Fee for 118 and 128 S.Barclay.=$80.00 JEREMIAH VANDYKE-10/02/2023 @ 16:28 Clothes dryers cleaned by QK on 9/1/2023. JEREMIAH VANDYKE-10/02/2023 @ 16:48 70 kids limit for building. JEREMIAH VANDYKE-10/02/2023 @ 16:48 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address.Phone#319-291-2515. Printed on 10/02/2023 @ 16:53 Page 5 of 6 GENERAL NOTES JEREMIAH VANDYKE-10/02/2023 @ 16:49 Lt.Van Dyke-jeremiah.vandyke@waterloo-ia.org-Work:319-291-4460-Cell:319-883- 1615 REINSPECTION DATE 11/01/2023 CONTACT SIGNATURE Kimberly Kemp Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on: 10/02/2023 @ 16:52 Vi QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 10/02/2023 @ 16:53 Page 6 of 6