COMMERCIAL INSPECTION- 669 S HACKETT ST- 10-20-23 FOR BILLING INQUIRY: (319)291-4323
LDescription Total Price
INSPECTION 20,000 $90.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
4456 11/01/2023 12/10/2023 2024-00000138 $100.00
Less Prepayment $0.00
Total Due— $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE gonlp
INSPECTION REPORT
YMCA,669 S HACKETT,BLDG 669 S HACKETT RD, WATERLOO IA S0701
q."--k 4:01,
DETAILS
Inspection Date: 10/20/2023 Inspection Type:Annual Inspection(1Yr) I Inspection Number: 10010 Shift: N/A Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL ; Other Inspectors: N/A
STATUS CODE DESCRIPTION
FAIL 102.4-Application of building The design and construction of new structures shall comply with the International
code. Building Code,and any alterations,additions,changes in use or changes in
structures required by this code,which are within the scope of the International
Building Code,shall be made in accordance therewith.
Inspector:JEFF SIEBEL-Comments:Residential range in building:If range is used to
fry,sauté'or produce grease laden vapors install an approved type 1 hood with
approved fire suppression system. If not used for these purposes:A. Install a type 2
hood that covers the entire cooking surface. B. Install permanent red sign with white
engraved letters stating"No Frying,sauteing or producing of grease laden vapors.C.
Install a 2A-10 BC fire extinguisher in room.D.Sign a light duty kitchen hood user
agreement with the City of Waterloo.(attached)
Location:kitchen
Printed on 10/23/2023 @ 10:42
Page 1 of 5
STATUS CODE DESCRIPTION
FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
Inspector:JEFF SIEBEL-Comments: BOTH REPEAT OFFENSES; Remove all storage from
both egress paths. Back hall is already signed.Install permanent signage in hall from
CM ® daycare.
Location: Hall to daycare outside of kitchen Back Hall behind daycare
s
i ` ss
'7'3: 40 i --
m
t a'
fir•-iis:10'r ' t'�.
.'"gifaipziligio...
N.
_ e
FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments: Repair exit light
Location: Men's Reg Locke room Main Door
Printed on 10/23/2023 @ 10:42
Page 2 of 5
STATUS CODE DESCRIPTION
FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments:repair egress/exit light
Location:door from Big pool to little pool
FAIL 403.4.1 -First emergency The first emergency evacuation drill of each school year shall be conducted within 10
evacuation drill. days of the beginning of classes.
Inspector:JEFF SIEBEL-Comments: Provide documentation of Fire drills practiced,
last fire drill and number of children.
Location: Not Provided
FAIL 603.8-Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations
shall not exceed is allowed for a period not to exceed of 90 days.Temporary wiring
methods shall meet the applicable provisions of NFPA 70.Exception:Temporary
wiring for electrical power and lighting installations is allowed complying with the
applicable provisions of NFPA 70 is permitted during periods of construction,
remodeling,repair or demolition of buildings,structures,equipment or similar
activities.
Inspector:JEFF SIEBEL-Comments: Decorative lights located here and other locations
must be removed after 90 days use.
Location: Montessari
FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems
protection. used to protect joints and voids in the following locations shall be maintained.The
materials and systems shall be securely attached to or bonded to the adjacent
construction,without openings visible through the construction. 1.Joints in or
between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a
horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a
horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a
nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the
intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the
intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.
Unprotected joints and voids do not need to be protected where such joints and
voids were not required to be protected when the building was originally
constructed.Where the system design number is known,the system shall be
inspected to the listing criteria and manufacturer's installation instructions.
Inspector:JEFF SIEBEL-Comments:All fire doors must remain closed or be held open
by a fire alarm magnet release system.Many doors were propped open.
Location:Numerous stair fire doors wellness center to staff break room stairs-
REPEAT VIOLATION landing on stairs to track and basement.
Printed on 10/23/2023 @ 10:42
Page 3 of 5
STATUS CODE DESCRIPTION
FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically.
Inspector:JEFF SIEBEL-Comments:Fire doors must completely self-close and latch
Location: From lobby to wellness center
FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically.
Inspector:JEFF SIEBEL-Comments: Fire doors must completely self-close and latch
Location:To basement stairs from YMCA Presidents Wall
FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically.
Inspector:JEFF SIEBEL-Comments:doors must completely self-close and latch.
Location: Fire door pool equipment room
FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically.
Inspector:JEFF SIEBEL-Comments:Door must completely self-close and latch.
Missing hardware. REPEAT VIOLATION.
Location: Door from spa equipment room to AHU Room
FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically.
Inspector:JEFF SIEBEL-Comments:Fire doors must completely self-close and latch.
Doors were propped open,.
Location: Landing on stairs to track and basement
FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor
testing,and maintenance
Inspector:JEFF SIEBEL-Comments:Provide current annual fire alarm inspection
report with all discrepancies corrected.Contractor must upload online to the
compliance engine.
Location: Not Provided
GENERAL NOTES
JEFF SIEBEL-10/20/2023 @ 14:47 annual inspection fee$100
Printed on 10/23/2023 @ 10:42
Page 4 of 5
GENERAL NOTES
JEFF SIEBEL-10/20/2023 @ 14:53 Dryer vent cleaned to the outside by Harris Cleaning 3/23/23
JEFF SIEBEL-10/23/2023 @ 09:21 un secured co tanks tanks in pool equipment room were corrected during inspection.
JEFF SIEBEL-10/20/2023 @ 14:47 Fire Sprinkler inspection will be due 10/24/23
REINSPECTION DATE
11/16/2023
CONTACT SIGNATURE
Mitch Gates 2023
Signed on: 10/23/2023 @ 10:40
�,l
�7
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:10/23/2023 @ 10:40