Loading...
HomeMy WebLinkAbout669 HACKETT ST W A T INVOICE DATE DUE DATE INVOICE# TOTAL DUE c 11/01/2023 12/10/2023 2024-00000138 $100.00 rrrrrn b 0 1vt,' Customer#: 4456 Please Make Check Payable and Remit To: City of Waterloo A TTN: City Clerk/Accounts Receivable YMCA 715 Mulberry St 669 S HACKETT RD WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 669 S HACKETT ST- 10-20-23 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4456 11/01/2023 12/10/2023 2024-00000138 $100.00 Less Prepayment $0.00 Total Due— $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE gonlp INSPECTION REPORT YMCA,669 S HACKETT,BLDG 669 S HACKETT RD, WATERLOO IA S0701 q."--k 4:01, DETAILS Inspection Date: 10/20/2023 Inspection Type:Annual Inspection(1Yr) I Inspection Number: 10010 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL ; Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 102.4-Application of building The design and construction of new structures shall comply with the International code. Building Code,and any alterations,additions,changes in use or changes in structures required by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Inspector:JEFF SIEBEL-Comments:Residential range in building:If range is used to fry,sauté'or produce grease laden vapors install an approved type 1 hood with approved fire suppression system. If not used for these purposes:A. Install a type 2 hood that covers the entire cooking surface. B. Install permanent red sign with white engraved letters stating"No Frying,sauteing or producing of grease laden vapors.C. Install a 2A-10 BC fire extinguisher in room.D.Sign a light duty kitchen hood user agreement with the City of Waterloo.(attached) Location:kitchen Printed on 10/23/2023 @ 10:42 Page 1 of 5 STATUS CODE DESCRIPTION FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEFF SIEBEL-Comments: BOTH REPEAT OFFENSES; Remove all storage from both egress paths. Back hall is already signed.Install permanent signage in hall from CM ® daycare. Location: Hall to daycare outside of kitchen Back Hall behind daycare s i ` ss '7'3: 40 i -- m t a' fir•-iis:10'r ' t'�. .'"gifaipziligio... N. _ e FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments: Repair exit light Location: Men's Reg Locke room Main Door Printed on 10/23/2023 @ 10:42 Page 2 of 5 STATUS CODE DESCRIPTION FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair egress/exit light Location:door from Big pool to little pool FAIL 403.4.1 -First emergency The first emergency evacuation drill of each school year shall be conducted within 10 evacuation drill. days of the beginning of classes. Inspector:JEFF SIEBEL-Comments: Provide documentation of Fire drills practiced, last fire drill and number of children. Location: Not Provided FAIL 603.8-Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations shall not exceed is allowed for a period not to exceed of 90 days.Temporary wiring methods shall meet the applicable provisions of NFPA 70.Exception:Temporary wiring for electrical power and lighting installations is allowed complying with the applicable provisions of NFPA 70 is permitted during periods of construction, remodeling,repair or demolition of buildings,structures,equipment or similar activities. Inspector:JEFF SIEBEL-Comments: Decorative lights located here and other locations must be removed after 90 days use. Location: Montessari FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:All fire doors must remain closed or be held open by a fire alarm magnet release system.Many doors were propped open. Location:Numerous stair fire doors wellness center to staff break room stairs- REPEAT VIOLATION landing on stairs to track and basement. Printed on 10/23/2023 @ 10:42 Page 3 of 5 STATUS CODE DESCRIPTION FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:JEFF SIEBEL-Comments:Fire doors must completely self-close and latch Location: From lobby to wellness center FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:JEFF SIEBEL-Comments: Fire doors must completely self-close and latch Location:To basement stairs from YMCA Presidents Wall FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:JEFF SIEBEL-Comments:doors must completely self-close and latch. Location: Fire door pool equipment room FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:JEFF SIEBEL-Comments:Door must completely self-close and latch. Missing hardware. REPEAT VIOLATION. Location: Door from spa equipment room to AHU Room FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:JEFF SIEBEL-Comments:Fire doors must completely self-close and latch. Doors were propped open,. Location: Landing on stairs to track and basement FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEFF SIEBEL-Comments:Provide current annual fire alarm inspection report with all discrepancies corrected.Contractor must upload online to the compliance engine. Location: Not Provided GENERAL NOTES JEFF SIEBEL-10/20/2023 @ 14:47 annual inspection fee$100 Printed on 10/23/2023 @ 10:42 Page 4 of 5 GENERAL NOTES JEFF SIEBEL-10/20/2023 @ 14:53 Dryer vent cleaned to the outside by Harris Cleaning 3/23/23 JEFF SIEBEL-10/23/2023 @ 09:21 un secured co tanks tanks in pool equipment room were corrected during inspection. JEFF SIEBEL-10/20/2023 @ 14:47 Fire Sprinkler inspection will be due 10/24/23 REINSPECTION DATE 11/16/2023 CONTACT SIGNATURE Mitch Gates 2023 Signed on: 10/23/2023 @ 10:40 �,l �7 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:10/23/2023 @ 10:40 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 10/23/2023 @ 10:42 Page 5 of 5