Loading...
HomeMy WebLinkAbout120 JEFFERSON ST W A T INVOICE DATE DUE DATE INVOICE# TOTAL DUE Q , F 11/01/2023 12/10/2023 2024-00000140 $80.00 0 • t I� a to •.r..r � { s Customer#: 4639 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HAWKEYE CHILD DEVELOPMENT CENTER 715 Mulberry St PO BOX 8015 WATERLOO, IA 50703 WATERLOO, IA 50704 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 120 JEFFERSON ST- 10-19-23 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4639 11/01/2023 12/10/2023 2024-00000140 $80.00 Less Prepayment $0.00 Total Due—* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. �� SERA WATERLOO FIRE RESCUE v,vs, �P INSPECTION REPORT ,at HAWK EYE CHILD CARE CENTER MC,120 JEFFERSON ST,BLDG 120 JEFFERSON ST., WATERLOO/A S0702 42ZZOk DETAILS Inspection Date: 10/19/2023 i Inspection Type:Annual Inspection(1Yr) ,,.tospection Number:9330 Shift: N/A Station: N/A I Unit: N/A Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1010.1.3-Door opening The force for pushing or pulling open interior swinging egress doors,other than fire force Forces to unlatch and doors,shall not exceed 5 pounds(22 N).These forces do not apply to the force open doors. required to retract latch bolts or disengage other devices that hold the door in a closed position. For other swinging doors,as well as sliding and folding doors,the door latch shall release when subjected to a 15-pound(67 N)force.The door shall be set in motion when subjected to a 30-pound(133 N)force.The door shall swing to a full-open position when subjected to a 15-pound(67 N)force.The forces to unlatch doors shall comply with the following: 1.Where door hardware operates by push or pull,the operational force to unlatch the door shall not exceed 15 pounds(66.7 N). 2.Where door hardware operates by rotation,the operational force to unlatch the door shall not exceed 28 inch-pounds(315 N-cm).The force to open doors shall comply with the following: 1.For interior swinging egress doors that are manually operated,other than doors required to be fire rated,the force for pushing or pulling open the door shall not exceed 5 pounds(22 N).2.For other swinging doors,sliding doors or folding doors,and doors required to be fire rated,the door shall require not more than a 30-pound(133 N)force to be set in motion and shall move to a full- open position when subjected to not more than a 15-pound(67 N)force. Inspector:JEFF SIEBEL-Comments: Repair north egress gate,must open with less than 15#force. Location: North Gate of North outdoor play area. FAIL 1203.4.3-Records. Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEFF SIEBEL-Comments:Provide documentation of emergency egress and exit lights including central battery station with all discrepancies corrected. Location: Not Provided Printed on 10/20/2023 @ 09:27 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 509.1 -Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements fire protection systems shall be identified for the use of the fire department.Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Inspector:JEFF SIEBEL-Comments: Install permanent signage on outside of door "FACP"or Fire Department Remote Command Center. Location: Door 11 ,west side of building to Fire Department Remote Command Center. FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:Replace misplaced ceiling tile Location: Laundry Room GENERAL NOTES JEFF SIEBEL-10/20/2023 @ 09:21 Fire drills completed monthly.Last 9/7/23 with 28 children. JEFF SIEBEL-10/20/2023 @ 09:22 Dryer vent cleaning by Chris Shannon 10/5/23 JEFF SIEBEL-10/20/2023 @ 09:06 Annual inspection fee$80 REINSPECTION DATE 11/16/2023 Printed on 10/20/2023 @ 09:27 Page 2 of 3 CONTACT SIGNATURE Sarah Errthum Signed on: 10/20/2023 @ 09:20 L INSPECTOR SIGNATURE JEFF SIEBEL Signed on: 10/20/2023 @ 09:20 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL JeffSiebel@Waterloo-ia.org 3192301224 Printed on 10/20/2023 @ 09:27 Page 3 of 3