Loading...
HomeMy WebLinkAbout2126 KIMBALL AVE WA T INVOICE DATE DUE DATE INVOICE# TOTAL DUE e 11/01/2023 12/10/2023 2024-00000142 $80.00 r�rrr A 0 0 Customer#: 12084 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HY-VEE WINE& SPIRITS 715 Mulberry St 2126 KIMBALL AV WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-2126 KIMBALL AVE- 9-28-23 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 12084 11/01/2023 12/10/2023 2024-00000142 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. LI\ WATERLOO FIRE RESCUE �pSERLO4CO INSPECTION REPORT i� HY-VEE WINE&SPIRITS#1,2126 KIMBALL AVE,BLDG 2126 KIMBALL AVE,WATERLOO/A S0701 41740 DETAILS Inspection Date:09/28/2023 Inspection Type:Annual Inspection(1Yr) j Inspection Number:8900 Shift: N/A ! Station: N/A i Unit: N/A ' Lead Inspector:JEFF SIEBEL Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair exit/egress light Location: Main Front Exit FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Inspector:JEFF SIEBEL-Comments:Remove orange and green extension cords. Power strip with manual reset may be used for electronic devices(including temporary holiday decorations).Protect cord with a U.L. listed cord protector in walking path. Location:behind counter Printed on 10/04/2023 @ 09:17 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile(2) Location: Back room GENERAL NOTES JEFF SIEBEL-10/04/2023 @ 09:14 annual inspection$80 REINSPECTION DATE 10/18/2023 CONTACT SIGNATURE Tracy Hahn Signed on:10/04/2023 @ 09:15 aG� INSPECTOR SIGNATURE JEFF SIEBEL Signed on:10/04/2023 @ 09:15 Printed on 10/04/2023 @ 09:17 Page 2 of 3 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 10/04/2023 @ 09:17 Page 3 of 3