Loading...
HomeMy WebLinkAbout3469 W AIRLINE HWY OF W 4 .F INVOICE DATE DUE DATE INVOICE# TOTAL DUE 07/20/2023 08/25/2023 2024-00000055 $80.00 0 u tittvo. 0 0 3S "ibt0k� Customer#: 10547 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable MURPHY TRACTOR&EQUIPMENT CO 715 Mulberry St 3469 W AIRLINE HWY WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-3469 W AIRLINE HWY- 7-19-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 10547 07/20/2023 08/25/2023 2024-00000055 $80.00 Less Prepayment $0.00 Total Due —÷ $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. • WATERLOO FIRE RESCUE ‘ • INSPECTION REPORT MURPHY TRACTOR,3469 WAIRLINE HWY,BLDG 3469 WAIRLINE HWY,WATERLOO/A 50703 DETAILS Inspection Date:07/19/2023 i Inspection Type:Annual Inspection(1 Yr) Inspection Number:203 ; Shift: N/A Station: N/A Unit: N/A ! Lead Inspector:JEREMIAH VANDYKE Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEREMIAH VANDYKE-Comments:Need to address all Exit and Egress lights throughout building.Some did work and others did not when tested. Location: Entire Building including stairways and mechanical rooms. fi NOTICE FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEREMIAH VANDYKE-Comments: Need to address all Exit and Egress lights throughout building.Some did work and others did not when tested. ra Location: Entire Building including stairways and mechanical rooms. f �RI .R FAIL 304.3.1 -Spontaneous Materials susceptible to spontaneous ignition,such as oily rags,shall be stored in a ignition. listed disposal container.Contents of such containers shall be removed and disposed of daily. Inspector:JEREMIAH VANDYKE-Comments:Oily rags must be disposed properly in UL listed disposal container. Location: Located in wash bay. Printed on 07/19/2023 @ 15:54 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 5303.5.3-Securing Compressed gas containers,cylinders and tanks shall be secured to prevent falling compressed gas containers, caused by contact,vibration or seismic activity.Securing of compressed gas cylinders and tanks. containers,cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks.3. Nesting of compressed gas containers,cylinders and tanks at container filling or servicing kyr, facilities or in sellers'warehouses not open to the public. Nesting shall be allowed 116110 provided that the nested containers,cylinders or tanks, if dislodged,do not obstruct the required means of egress.4.Securin of compressedgas containers,cylinders 9 g g p y ,teA' and tanks to or within a rack,framework,cabinet or similar assembly designed for such use. Exception:Compressed gas containers,cylinders and tanks in the process tea, of examination,filling,transport or servicing. Inspector:JEREMIAH VANDYKE-Comments:Tanks must be secured. Location:Wash bay garage FAIL 705.2-Inspection and Opening protectives in fire-resistance-rated assemblies shall be inspected and maintenance. maintained in accordance with NFPA 80.Opening protectives in smoke barriers shall be inspected and maintained in accordance with NFPA 80 and NFPA 105.Openings in smoke partitions shall be inspected and maintained in accordance with NFPA 105. Fire doors and smoke and draft control doors shall not be blocked,obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged.Opening protectives and smoke and draft control doors shall not be modified. Inspector:JEREMIAH VANDYKE-Comments: Missing ceiling 2 ceiling tile that need to be replaced. Location:2nd floor IT/server room. FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEREMIAH VANDYKE-Comments: Fire alarm is to be inspected annually by licensed contractor and inspection report uploaded to compliance engine by Fire alarm contractor. Location:Not Provided GENERAL NOTES JEREMIAH VANDYKE-07/19/2023 @ 15:50 Fire Extinguisher serviced by Pro Shield in May 2023. JEREMIAH VANDYKE-07/19/2023 @ 15:51 Space heaters are to be plugged directly into wall outlets and not into power strips or extension cords. Printed on 07/19/2023 @ 15:54 Page 2 of 4 • GENERAL NOTES JEREMIAH VANDYKE-07/19/2023 @ 15:51 Extension cords in shop are not to be used as temporary wiring. JEREMIAH VANDYKE-07/19/2023 @ 15:52 AED located in office.Discussed use and that someone should be properly trained to use. JEREMIAH VANDYKE-07/19/2023 @ 15:53 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address. Phone#319-291-2515. JEREMIAH VANDYKE-07/19/2023 @ 15:53 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m. If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-07/19/2023 @ 15:53 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-07/19/2023 @ 15:53 Inspection Fee=$80.00 REINSPECTION DATE 08/18/2023 CONTACT SIGNATURE Colton Chase Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:07/19/2023 @ 15:53 VL) Printed on 07/19/2023 @ 15:54 Page 3 of 4 � r • QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 07/19/2023 @ 15:54 Page 4 of 4