Loading...
HomeMy WebLinkAbout3470 w airline hwy 0 WA Tk• qTk• INVOICE DATE DUE DATE INVOICE# TOTAL DUE 4. 41 07/20/2023 08/25/2023 2024-00000064 $610.00 u.,riiir�•►. O ijaP`1% ) O vY t) Customer#: 24159 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable G&R INTEGRATION 715 Mulberry St 3470 W AIRLINE HWY WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-3470 W AIRLINE HWY- 7-21-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price INSPECTION 100,000 $600.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24159 07/20/2023 08/25/2023 2024-00000064 $610.00 Less Prepayment $0.00 Total Due $610.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. �pSER��O WATERLOO FIRE RESCUE1,\Og*ci‘s INSPECTION REPORT \ • 6 Br R INTEGRATION,3470 W AIRLINE HWY,BLD6 3470 W AIRLINE HWY,WATERLOO IA 50703 DETAILS Inspection Date:07/21/2023 ; Inspection Type:Annual Inspection(1Yr) I Inspection Number:202 Shift: N/A Station: N/A ; Unit: N/A Lead Inspector:JEREMIAH VANDYKE I Other Inspectors:JEFF SIEBEL Fee:$610.00 STATUS CODE DESCRIPTION FAIL 1010.2.9-Panic and fire exit Swinging doors serving a Group H occupancy and swinging doors serving rooms or hardware. spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock other than panic hardware or fire exit hardware. Exceptions: 1.A main exit of a Group A occupancy shall be permitted to have locking devices in accordance with Section 1010.2.4, Item 2 3.2.Doors provided with panic hardware or fire exit hardware and serving a Group A or E occupancy shall be permitted to be electrically locked in accordance with Section 1010.2.12 or 1010.2.11. 3. Exil:access doors serving occupied exterior areas shall be permitted to be locked in accordance with Section 1010.2.4, Item 8.4.Courtrooms shall be permitted to be locked in accordance with Section 1010.2.13,Item 3.Electrical rooms with equipment rated 1,200 amperes or more and over 6 feet(1829 mm)wide,and that contain overcurrent devices,switching devices or control devices with exit or exit access doors,shall be equipped with panic hardware or fire exit hardware.The doors shall swing in the direction of egress travel. Inspector:JEREMIAH VANDYKE-Comments:Must remove dead bolt from front office doors since there is panic hardware and marked exit. Location:OLD Office FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEREMIAH VANDYKE-Comments:All Exit and emergency Egress lights need to be repaired by licensed electrician. Location: Entire Building including Old office area. FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEREMIAH VANDYKE-Comments:All Exit and emergency Egress lights need to be repaired by licensed electrician. Location: Entire Building including old office area. Printed on 07/21/2023 @ 17:22 Page 1 of 7 STATUS CODE DESCRIPTION FAIL 1203.4.3-Records. Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service,name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEREMIAH VANDYKE-Comments:Records of electrician's work needed for repairs done. Location: Entire building. FAIL 5003.8.7.1 -Construction. The interior of cabinets shall be treated,coated or constructed of materials that are nonreactive with the hazardous material stored.Such treatment,coating or construction shall include the entire interior of the cabinet.Cabinets shall either be listed in accordance with UL 1275 as suitable for the intended storage or constructed in accordance with the following: 1.Cabinets shall be of steel having a thickness of not less than 0.0478 inch(1.2 mm)(No.18 gage).The cabinet,including the door,shall be double walled with a 11/2-inch(38 mm)airspace between the walls.Joints shall be riveted or welded and shall be tight fitting. Doors shall be well fitted,self-closing and equipped with a self-latching device.2.The bottoms of cabinets utilized for the storage of liquids shall be liquid tight to a minimum height of 2 inches(51 mm). Electrical equipment and devices within cabinets used for the storage of hazardous gases or liquids shall be in accordance with NFPA 70. Inspector:JEREMIAH VANDYKE-Comments: Need self closing kits installed on all Yellow hazardous cabinets. Location:All Yellow hazardous cabinets in entire building. FAIL 509.1 -Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements fire protection systems shall be identified for the use of the fire department.Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Inspector:JEREMIAH VANDYKE-Comments: None Location:Signage needed on door of 2nd floor office area stating"FACP"where main fire alarm panel is located. Printed on 07/21/2023 @ 17:22 Page 2 of 7 STATUS CODE DESCRIPTION FAIL 509.1 -Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems,sprinkler risers and valves,or other fire detection,suppression or control elements fire protection systems shall be identified for the use of the fire department.Approved signs required to identify fire protection system equipment and equipment location shall be constructed of durable materials, permanently installed and readily visible. Inspector:JEREMIAH VANDYKE-Comments: Need to have signage from sprinkler contractor for proper signs on sprinkler risers. Location:All Sprinkler Risers FAIL 5701.1 -Scope and Prevention,control and mitigation of dangerous conditions related to storage,use, application. dispensing, mixing and handling of flammable and combustible liquids shall be in accordance with Chapter 50 and this chapter. Inspector:JEREMIAH VANDYKE-Comments:2 Gas lines need to capped properly. Location: Near door#14 and middle of building C near ceiling east of#14. FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated.Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Inspector:JEREMIAH VANDYKE-Comments: Need to have licensed electrician go through entire building and assess panels for damage,broken breakers,or missing breakers. Location:All electrical panels on building poles in entire building. 1.Panel by door#8 has missing and broken breakers.2. Panel east of door#8 by forklift charging area. FAIL 603.2-Abatement of unsafe Identified electrical hazards shall be abated. Identified hazardous electrical conditions conditions and electrical in permanent wiring shall be brought to the attention of the responsible code official. hazards. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. Inspector:JEREMIAH VANDYKE-Comments:All electrical and electrical panel needs to be assessed by electrician OR discussed having the old office area torn down.Office Location:OLD OFFICE BUILDING. Printed on 07/21/2023 @ 17:22 Page 3 of 7 STATUS CODE DESCRIPTION FAIL 704.1 -Maintaining Where required when the building was originally constructed,materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEREMIAH VANDYKE-Comments:Ceiling tiles missing and need replaced. Location: 1.IT room 2nd floor.2.Break room. FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:JEREMIAH VANDYKE-Comments:Walk through doors between building A, B,and C must be self closing doors. Doors had broken self closing equipment. Location:Walk through doors between Buildings A, B,and C. FAIL 901.4.5-Additional fire In occupancies of a hazardous nature,where special hazards exist in addition to the protection systems. normal hazards of the occupancy,or where the fire code official determines that access for fire apparatus is unduly difficult,the fire code official shall have the authority to require additional safeguards.Such safeguards include, but shall not be limited to,the following:automatic fire detection systems,fire alarm systems, automatic fire-extinguishing systems,standpipe systems,or portable or fixed extinguishers. Fire protection equipment and fire protection systems. Fire protection and life safety systems required under this section shall be installed in accordance with this code and the applicable referenced standards. Inspector:JEREMIAH VANDYKE-Comments: FROM COMPLIANCE ENGINE:Deficiency Found:Answer:More tire storage on west side of building is need of design review issue. Location:Called out by Sprinkler contractor. Printed on 07/21/2023 @ 17:22 Page 4 of 7 • STATUS CODE DESCRIPTION FAIL 901.4.5-Additional fire In occupancies of a hazardous nature,where special hazards exist in addition to the protection systems. normal hazards of the occupancy,or where the fire code official determines that access for fire apparatus is unduly difficult,the fire code official shall have the authority to require additional safeguards.Such safeguards include,but shall not be limited to,the following:automatic fire detection systems,fire alarm systems, automatic fire-extinguishing systems,standpipe systems,or portable or fixed extinguishers. Fire protection equipment and fire protection systems. Fire protection and life safety systems required under this section shall be installed in accordance with this code and the applicable referenced standards. Inspector:JEREMIAH VANDYKE-Comments: 1.Sprinkler heads will need to be turned up by sprinkler contractor or ceiling tiles replaced throughout old office on both floors.2.Bathroom in basement of office has covered head. Location:OLD OFFICE FAIL 901.6-Inspection,testing and Fire detection and alarm systems,emergency alarm systems,gas detection systems, maintenance. fire-extinguishing systems, mechanical smoke exhaust systems and smoke and heat vents protection and life safety systems shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection and life safety systems and equipment shall be inspected,tested and maintained or removed in accordance with Section 901.8. Inspector:JEREMIAH VANDYKE-Comments: 15 deficiencies were called out by sprinkler contractor on Compliance Engine. Must be repaired by licensed sprinkler contractor and report uploaded to compliance engine by contractor. Location:Sprinkler system FAIL 903.3.1 -Standards. Sprinkler systems shall be designed and installed in accordance with Section 903.3.1.1,unless otherwise permitted by Sections 903.3.1.2 and 903.3.1.3 and other chapters of this code,as applicable. Inspector:JEREMIAH VANDYKE-Comments: Leaking sprinkler head in stairway leading to front entrance to be addressed by sprinkler contractor. Location:OLD office FAIL 906.6-Unobstructed and Portable fire extinguishers shall not be obstructed or obscured from view. In rooms unobscured. or areas in which visual obstruction cannot be completely avoided, means shall be provided to indicate the locations of extinguishers. Inspector:JEREMIAH VANDYKE-Comments: Many signs for fire extinguisher location were painted and need to be replaced. Location: Entire Building. FAIL 912.4.3-Physical protection. Where fire department connections are subject to impact by a motor vehicle,vehicle impact protection shall be provided in accordance with Section 312. Printed on 07/21/2023 @ 17:22 Page 5of7 • STATUS CODE DESCRIPTION Inspector:JEREMIAH VANDYKE-Comments: Broken Bollards need to be repaired. Location: In parking Lot C FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEREMIAH VANDYKE-Comments:Fire alarm is to be inspected annually by licensed contractor and report uploaded to Compliance engine website by contractor.Any deficiencies found during inspection must be repaired by contractor. Location: Fire alarm FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEREMIAH VANDYKE-Comments:Upstairs bathroom alarm notifier is hanging by wires and need to be addressed by fire alarm contractor. Location:OLD OFFICE GENERAL NOTES JEREMIAH VANDYKE-07/21/2023 @ 16:13 Fire extinguishers serviced by Pro shield in March 2023. JEREMIAH VANDYKE-07/21/2023 @ 16:13 Discussed AEDs on site and dead batteries that need to be addressed. JEREMIAH VANDYKE-07/21/2023 @ 16:16 Rolling fire door serviced by Overhead doors on 7/3/2023. JEREMIAH VANDYKE-07/21/2023 @ 17:18 OLD OFFICE:Discussed with Matt Zuke about them possible demolition of Old office building due to the electrical issues,fire alarm issues,sprinkler head issues,exit signs issues,and black mold.He said he would discuss with owner. JEREMIAH VANDYKE-07/21/2023 @ 17:19 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address.Phone#319-291-2515. JEREMIAH VANDYKE-07/21/2023 @ 17:19 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. Printed on 07/21/2023 @ 17:22 Page 6 of 7 GENERAL NOTES JEREMIAH VANDYKE-07/21/2023 @ 17:19 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-07/21/2023 @ 17:19 Inspection Fee=$610.00 REINSPECTION DATE 08/20/2023 CONTACT SIGNATURE Matt Zuke Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:07/21/2023 @ 17:15 S20 D QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 07/21/2023 @ 17:22 Page 7 of 7