COMMERCIAL INSPECTION- 618 SYCAMORE ST- 7-31-23 FOR BILLING INQUIRY: (319)291-4323
Description Total Price J
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
24163 08/01/2023 09/05/2023 2024-00000076 $80.00
Less Prepayment $0.00
Total Due $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
3
1\0
WATERLOO FIRE RESCUE
INSPECTION REPORT
PS TREASURES AND COLLECTIBLES,618 SYCAMORE ST,BLDG 618 SYCAMORE ST,WATERLOO
IA 50703 4 0
DETAILS
Inspection Date:07/31/2023 I Inspection Type:Annual Inspection(1Yr) Inspection Number:8743 Shift: N/A ' Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL ! Other Inspectors: N/A Fee:$80.00
STATUS CODE DESCRIPTION
FAIL 603.2.2-Unapproved Open junction boxes and open-wiring splices shall be prohibited.Approved covers
conditionsOpen electrical shall be provided for all switch and electrical outlet boxes.
terminations.
Inspector:JEFF SIEBEL-Comments: Install all missing outlet,and switch covers. Install
all missing junction box covers.
Location:through-out store
FAIL 906.2-General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance
with this section and NFPA 10.Exceptions:1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall be
allowed to be once every 3 years for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1.Electronic monitoring
shall confirm that extinguishers are properly positioned,properly charged and
unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring
device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a
building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices
and supervisory circuits shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at the
frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be
permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments: Provide current annual service for all fire
extinguishers
Location:upstairs and downstairs
GENERAL NOTES
JEFF SIEBEL-08/01/2023 @ 10:13 annual inspection$80
REINSPECTION DATE
08/21/2023
Printed on 08/01/2023 @ 10:14
Page 1 of 2
CONTACT SIGNATURE
Steve SpragueK
Signed on:08/01/2023 @ 10:13 �;c 'G -�
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:08/01/2023 @ 10:13
QUESTIONS AIOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 08/01/2023 @ 10:14
Page 2 of 2