Loading...
HomeMy WebLinkAbout618 SYCAMORE ST (2) O W A T INVOICE DATE DUE DATE INVOICE# TOTAL DUE "Ps < 08/01/2023 09/05/2023 2024-00000077 $80.00 o u �,�i«ray►• • • 4.4 7 V t Customer#: 21840 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BROWN DERBY BALLROOM 715 Mulberry St 215 E 4TH ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 618 SYCAMORE ST- 7-31-23 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 21840 08/01/2023 09/05/2023 2024-00000077 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. ,,\ 0 OP )10 WATERLOO FIRE RESCUE 44PtERLoo a\ INSPECTION REPORT BROWN DERBY,618 SYCAMORE ST,BLDG 618 SYCAMORE ST,WATERLOO/A 50703 42406 DETAILS Inspection Date:07/31/2023 Inspection Type:Annual Inspection(1Yr) j Inspection Number:8745 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL I Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair egress light Location:by front door FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair egress light Location: 1st floor Men's restroom FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair egress light Location:Top of the back stairs for Apt 5 FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair exit/egress light Location:By elevator 2nd floor FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:Repair exit/egress light Location:By Unit 2 Printed on 08/01/2023 @ 09:43 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:JEFF SIEBEL-Comments: Fire door by elevator must completely self-close and latch. Location:2nd floor by elevator FAIL 705.2.4-Door operation. Swinging fire doors shall close from the full-open position and latch automatically. Inspector:JEFF SIEBEL-Comments:Remove foot drop down hold open devices from the fire doors. Must self close and latch.Hold open devices connected to the fire alarm system are allowed. Location:2nd floor men's and women's restrooms. FAIL 705.2.6-Testing. Horizontal and vertical sliding and rolling fire doors shall be inspected and tested annually to confirm proper operation and full closure. Records of inspections and testing shall be maintained. Inspector:JEFF SIEBEL-Comments: Provide documentation of current annual fire door drop test.label illegible. Location:2nd floor elevator fire door FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-S occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual fire extinguisher inspection. Location:entire building Printed on 08/01/2023 @ 09:43 Page 2 of 3 STATUS CODE DESCRIPTION FAIL 906.7-Hangers and brackets. Hand-held portable fire extinguishers,not housed in cabinets,shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:All fire extinguishers must be properly mounted Location: Not Provided GENERAL NOTES JEFF SIEBEL-08/01/2023 @ 09:43 annual inspection$80 REINSPECTION DATE 08/21/2023 CONTACT SIGNATURE Matt K. / Signed on:08/01/2023 @ 09:40 / `� i /'-1 --t INSPECTOR SIGNATURE JEFF SIEBEL Signed on:08/01/2023 @ 09:41 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 08/01/2023 @ 09:43 Page 3 of 3