Loading...
HomeMy WebLinkAbout1512 FLAMANG DR 0 W A r.k• INVOICE DATE DUE DATE INVOICE# TOTAL DUE 07/26/2023 08/30/2023 2024-00000068 $80.00 de. o .,frlf e. o •��■�r rr•e••••ri • > .,,.'."�.�„T O Customer#: 11161 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable HY-VEE GAS #3 715 Mulberry St 1512 FLAMMANG DR WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1512 FLAMANG DR- 7-24-23 FOR BILLING INQUIRY: (319)291-4323 1_Description I Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 11161 07/26/2023 08/30/2023 2024-00000068 $80.00 Less Prepayment $0.00 Total Due — $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUEcoma INSPECTION REPORT , I) HY-VEE GAS#3,1512 FLAMMANG DR,BLDG 1512 FLAMMANG DR,WATERLOO IA 50702 DETAILS V Inspection Date:07/24/2023 Inspection Type:Annual Inspection(1Yr) Inspection Number:8996 Shift: N/A ! Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL j Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 102.4-Application of building The design and construction of new structures shall comply with the International code. Building Code,and any alterations,additions,changes in use or changes in structures required by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Inspector:JEFF SIEBEL-Comments:Obtain permits and final inspections for all plumbing and electrical work completed without permits.(pizza outlet,water heater, 3 compartment sink) Location: Not Provided FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Inspector:JEFF SIEBEL-Comments:Remove extension cord to freezer. Freezer must plug directly into wall outlet. Location:freezer by coffee machine Printed on 07/25/2023 @ 08:32 Page 1 of 2 STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned, properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguisher Location:Not Provided REINSPECTION DATE 08/14/2023 CONTACT SIGNATURE Denise Greene \7(4. Signed on:07/25/2023 @ 08:24 L - I n INSPECTOR SIGNATURE JEFF SIEBEL Signed on:07/25/2023 @ 08:24 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 07/25/2023 @ 08:32 Page 2 of 2