COMMERCIAL INSPECTION- 1512 FLAMANG DR- 7-24-23 FOR BILLING INQUIRY: (319)291-4323
1_Description I Total Price J
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
11161 07/26/2023 08/30/2023 2024-00000068 $80.00
Less Prepayment $0.00
Total Due — $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUEcoma
INSPECTION REPORT , I)
HY-VEE GAS#3,1512 FLAMMANG DR,BLDG 1512 FLAMMANG DR,WATERLOO IA 50702
DETAILS V
Inspection Date:07/24/2023 Inspection Type:Annual Inspection(1Yr) Inspection Number:8996 Shift: N/A ! Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL j Other Inspectors: N/A
STATUS CODE DESCRIPTION
FAIL 102.4-Application of building The design and construction of new structures shall comply with the International
code. Building Code,and any alterations,additions,changes in use or changes in
structures required by this code,which are within the scope of the International
Building Code,shall be made in accordance therewith.
Inspector:JEFF SIEBEL-Comments:Obtain permits and final inspections for all
plumbing and electrical work completed without permits.(pizza outlet,water heater,
3 compartment sink)
Location: Not Provided
FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and
shall be listed and labeled in accordance with UL 817.Extension cords and flexible
cordsshall not be affixed to structures,extended through walls,ceilings or floors,or
under doors or floor coverings, nor shall such cords be subject to environmental
damage or physical impact.Extension cords shall be used only with portable
appliances. Extension cords marked for indoor use shall not be used outdoors.
Inspector:JEFF SIEBEL-Comments:Remove extension cord to freezer. Freezer must
plug directly into wall outlet.
Location:freezer by coffee machine
Printed on 07/25/2023 @ 08:32
Page 1 of 2
STATUS CODE DESCRIPTION
FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall be
allowed to be once every 3 years for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1.Electronic monitoring
shall confirm that extinguishers are properly positioned, properly charged and
unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring
device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a
building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices
and supervisory circuits shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at the
frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be
permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments:provide annual service for fire extinguisher
Location:Not Provided
REINSPECTION DATE
08/14/2023
CONTACT SIGNATURE
Denise Greene \7(4.
Signed on:07/25/2023 @ 08:24 L -
I n
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:07/25/2023 @ 08:24