Loading...
HomeMy WebLinkAbout2060 CROSSROADS BLVD OF W A . INVOICE DATE DUE DATE INVOICE# TOTAL DUE ,� �e 08/10/2023 09/15/2023 2024-00000082 $80.00 o iiiiiiiio p s 7 v i l N Customer#: 13921 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CHINA EXPRESS 715 Mulberry St 2060 CROSSROADS #242 WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-2060 CROSSROADS BLVD - 8-3-23 FOR BILLING INQUIRY: (319)291-4323 Description ITotal Price] INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 13921 08/10/2023 09/15/2023 2024-00000082 $80.00 Less Prepayment $0.00 Total Due--> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. „/),C12,•.\ • WA TERL OO FIRE RESCUE �PTER��O INSPECTION REPORT CHINA EXPRESS,2060 CROSSROADS BLVD,BLDG 2060 CROSSROADS BLVD-STE 242, WATERLOO/A 50702 4410 DETAILS Inspection Date:08/03/2023 j Inspection Type:Annual Inspection(1Yr) Inspection Number: 10786 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL ! Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair egress light Location: By bathroom FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. • Inspector:JEFF SIEBEL-Comments:repair egress light Location: kitchen above ice machine FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:Repair exit/egress light Location:kitchen FAIL 603.5-Relocatable power Multiplug adapters,such as cube adapters,unfused plug strips or any other device taps and current not complying with NFPA 70 shall be prohibited.The construction and use of current taps.Multiplug adapters. taps and relocatable taps shall be in accordance with NFPA 70 and this code. Inspector:JEFF SIEBEL-Comments:remove multi-plug adapter. Location:kitchen Printed on 08/04/2023 C 10:48 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Inspector:JEFF SIEBEL-Comments:remove extension cord from ceiling.Any device that produces heat,cooling or has a motor must plug directly into a wall outlet. Location:Kitchen area FAIL 807.2-Combustible In Groups A, B, E, I, M and R-1 and in dormitories in Group R-2,curtains,draperies, decorative materials. fabric hangings and other similar combustible decorative materials suspended from walls or ceilings shall comply with Section 807.3 and shall not exceed 10 percent of the specific wall or ceiling area to which such materials are attached. Fixed or movable walls and partitions,paneling,wall pads and crash pads applied structurally or for decoration,acoustical correction,surface insulation or other purposes shall be considered to be interior finish,shall comply with Section 803 and shall not be considered decorative materials or furnishings. Exceptions: 1.In auditoriums in Group A,the permissible amount of curtains,draperies,fabric hangings and similar combustible decorative material suspended from walls or ceilings shall not exceed 75 percent of the aggregate wall area where the building is equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1,and where the material is installed in accordance with Section 803.15 of the International Building Code.2.In Group R-2 dormitories,within sleeping units and dwelling units, the permissible amount of curtains,draperies,fabric hangings and similar decorative materials suspended from walls or ceilings shall not exceed 50 percent of the aggregate wall areas where the building is equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1.3.In Group B and M occupancies,the amount of combustible fabric partitions suspended from the ceiling and not supported by the floor shall comply with Section 807.3 and shall not be limited.4.The 10-percent limit shall not apply to curtains,draperies,fabric hangings and similar combustible decorative materials used as window coverings. Inspector:JEFF SIEBEL-Comments:Remove hanging curtains from dining room or provide documentation of complying with NFPA Standards for flame and smoke spread. Location:dining room GENERAL NOTES JEFF SIEBEL-08/04/2023 @ 10:45 annual inspection$80 REINSPECTION DATE 08/23/2023 Printed on 08/04/2023 @ 10:48 Page 2 of 3 CONTACT SIGNATURE Steven He Signed on:08/04/2023 @ 10:46 L INSPECTOR SIGNATURE JEFF SIEBEL Signed on:08/04/2023 @ 10:46 QUESTIONS AIOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 08/04/2023 @ 10:48 Page 3 of 3