Loading...
HomeMy WebLinkAbout2060 CROSSROADS BLVD (2) 0 W q 7.4' INVOICE DATE DUE DATE INVOICE# TOTAL DUE • ,.4* � 08/10/2023 09/15/2023 2024-00000083 $80.00 , o viso. • ) 4S 1vilN Customer#: 10928 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable GENO'S PIzzA 715 Mulberry St 2060 CROSSROADS #251 WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION -2060 CROSSROADS BLVD - 8-3-23 FOR BILLING INQUIRY: (319)291-4323 [Description Total Price'. INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 10928 08/10/2023 09/15/2023 2024-00000083 $80.00 Less Prepayment $0.00 Total Due—> $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. 47-1-1 WATERLOO FIRE RESCUE pSER(o .� INSPECTION REPORT 6ENOS PIS 2060 CROSSROADS BLVD,BLDG 2060 CROSSROADS BLVD-STE 251,WATERLOO `� IA S0702 4kig'` DETAILS Inspection Date:08/03/2023 i Inspection Type:Annual Inspection(1Yr) Inspection Number: 10798 Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL j Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 102.4-Application of building The design and construction of new structures shall comply with the International code. Building Code,and any alterations,additions,changes in use or changes in structures required by this code,which are within the scope of the International Building Code,shall be made in accordance therewith. Inspector:JEFF SIEBEL-Comments:Contact contractor to obtain water heater permit and final inspection.Incorrectly installed. Location:Water Heater FAIL 606.3.3.2-Grease If during the inspection it is found that hoods,grease-removal devices,fans,ducts or accumulation. other appurtenances have an accumulation of grease,such components shall be cleaned in accordance with ANSI/IKECA C10. Inspector:JEFF SIEBEL-Comments:Provide Bi-annual kitchen hood cleaning. Contractor must post online to the compliance engine. Location: Kitchen exhaust hood. FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:replace missing ceiling tile in back area. Location:back room Printed on 08/07/2023 @ 08:26 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10.Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3, portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments: Provide annual service for all fire extinguishers. Location: Not Provided FAIL 906.7-Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments: Properly hang fire extinguishers 4"to 5'above the floor. Location: Not Provided GENERAL NOTES JEFF SIEBEL-08/07/2023 @ 07:54 Annual fire inspection$80 REINSPECTION DATE 08/23/2023 CONTACT SIGNATURE Chris Wyckoff Signed on:08/07/2023 @ 08:24 I Printed on 08/07/2023 @ 08:26 Page 2 of 3 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:08/07/2023 @ 08:24 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 08/07/2023 @ 08:26 Page 3 of 3