Loading...
HomeMy WebLinkAbout2108 KIMBALL AVE 0 W 4 7. INVOICE DATE DUE DATE INVOICE# TOTAL DUE 08/10/2023 09/15/2023 2024-00000086 $80.00 o u.,riii4I► o � . a ... ... .; • 6 vas 7V11‘ Customer#: 9577 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable EAST CHINA 715 Mulberry St 2108 KIMBALL AV WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-2108 KIMBALL AVE- 8-2-23 FOR BILLING INQUIRY: (319)291-4323 Description I Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 9577 08/10/2023 09/15/2023 2024-00000086 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. CA611 ptEAG WATERLOO FIRE RESCUE , INSPECTION REPORT ! .� EAST CHINA,2108 KIMBALL AVE,BLDG 2108 KIMBALL AVE,WATERLOO/A 50702 DETAILS Inspection Date:08/02/2023 1 Inspection Type:Annual Inspection(1Yr) Inspection Number:4757 l Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A Fee:$80.00 STATUS CODE DESCRIPTION FAI L 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. .,k„ Inspector:JEFF SIEBEL-Comments:Remove all storage and screen door or remove 3 exit signs and properly contain wiring. Location: Back Hall q FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:repair egress light in dining room. Location: Dining room FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:Repair all exit lights in back hall and remove all P p g storage shelves and storage OR remove exit signs and properly contain all electrical connections. .40 Location: Back Hall FAIL 304.3.1 -Spontaneous Materials susceptible to spontaneous ignition,such as oily rags,shall be stored in a ignition. listed disposal container.Contents of such containers shall be removed and disposed of daily. Printed on 08/03/2023 @ 12:54 Page 1 of 8 STATUS CODE DESCRIPTION Inspector:JEFF SIEBEL-Comments:Provide an approved listed oily waste receptacle with self closing lid for all oily waste rags.See attached page. Location: Not Provided FAIL 305.1 -Clearance from Clearance between ignition sources,such as luminaires,heaters,flame-producing ignition sources. devices and combustible materials,shall be maintained in an approved manner. Inspector:JEFF SIEBEL-Comments: Remove storage from within 36"to furnace. . 4 Location: back hall .41111011 FAIL 5303.5.3-Securing Compressed gas containers,cylinders and tanks shall be secured to prevent falling compressed gas containers, caused by contact,vibration or seismic activity.Securing of compressed gas cylinders and tanks. containers,cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks.3. Nesting of #t' tt compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers'warehouses not open to the public.Nesting shall be allowed #, � provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct _ the required means of egress.4.Securing of compressed gas containers,cylinders . ' L►''s and tanks to or within a rack,framework,cabinet or similar assembly designed for ," s .,, ft such use. Exception:Compressed gas containers,cylinders and tanks in the process �'* of examination,filling,transport or servicing. m Inspector:JEFF SIEBEL-Comments:Remove compressed gas cylinder or properly secure in upright position with CHAIN Location:back hall shelving Printed on 08/03/2023 @ 12:54 Page 2of8 STATUS CODE DESCRIPTION • FAIL 603.5-Relocatable power Multiplug adapters,such as cube adapters,unfused plug strips or any other device taps and current not complying with NFPA 70 shall be prohibited.The construction and use of current taps.Multiplug adapters. taps and relocatable taps shall be in accordance with NFPA 70 and this code. Inspector:JEFF SIEBEL-Comments:Remove all kitchen appliances from power strip. Each appliance must plug directly into wall outlet. CLocation:dining room :11r FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Inspector:JEFF SIEBEL-Comments:Remove extension cord from camera.Extension cords not allowed. Location: Dining room FAIL 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other appurtenances shall be cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3. Inspector:JEFF SIEBEL-Comments:Provide current quarterly kitchen hood exhaust system inspection report with all discrepancies corrected. Report from AKA dated 3/14/23 lists 7 discrepancies.Contractor must upload corrections online to the compliance engine. Location:Kitchen Printed on 08/03/2023 @ 12:54 Page 3 of 8 STATUS CODE DESCRIPTION FAIL 606.3.3.1 -Inspection. Hoods,grease-removal devices,fans,ducts and other appurtenances shall be inspected at intervals specified in Table 606.3.3..1, or as approved by the fire code official. Inspections shall be completed by qualified individuals. Inspector:JEFF SIEBEL-Comments:Clean excessive grease and oil from hood filters. mit ,._ ` , Replace broken and missing filters. 2 Location:ktichen cm!° 606.3.3.2-Grease If during the inspection it is found that hoods,grease-removal devices,fans,ducts or accumulation. other appurtenances have an accumulation of grease,such components shall be cleaned in accordance with ANSI/IKECA C10. . . . - ''.'TT/ Inspector:JEFF SIEBEL-Comments:Remove all excessive grease from appliances, walls,floors, as piping etc. Must be completely cleaned before re-inspection. g pp g- p Y p ,.......„ ,...' ...,,,. ,,„..._..,.„., ...,,,,,,,,,,.. =,. , `_ iv:.-... Location:kitchen ..1.r.,,:,,..,,,.„,, . . f ‘,.,. .. , -..,,,_:,,, ,,‘,_.;--.,:ta.... , ,_.._ _ _Hts,..k,_,..._...,4, %-41-2 . ,-- 3' -p F' '3Y a. ey !_ f � Printed or 08/03/2023 @ 12:54 Page 4 of 8 STATUS CODE DESCRIPTION } g s �. ,Ie Sit g z s Sty ". - s_ fx�,z f ,,,,1-14,?t,..ik, 4ftr''' (7::.:\,‘---\- c i::,-,7i:_,'*;--,A \ '''--'*-7,.:-':,---7,-:!1,4", ''.',,„-._;-5.i .,_'-' +� 3 r ii54 va41+ I Printed on 08iO3i2023 @ 12:54 Page5of8 STATUS CODE DESCRIPTION FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems protection. used to protect joints and voids in the following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction. 1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly. Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Inspector:JEFF SIEBEL-Comments:Replace missing ceiling tile. Location: Back Hall and kitchen FAIL 807.2-Combustible In Groups A,B, E, I,M and R-1 and in dormitories in Group R-2,curtains,draperies, decorative materials. fabric hangings and other similar combustible decorative materials suspended from walls or ceilings shall comply with Section 807.3 and shall not exceed 10 percent of the specific wall or ceiling area to which such materials are attached.Fixed or movable walls and partitions, paneling,wall pads and crash pads applied structurally or for decoration,acoustical correction,surface insulation or other purposes shall be considered to be interior finish,shall comply with Section 803 and shall not be considered decorative materials or furnishings. Exceptions: 1.In auditoriums in Group A,the permissible amount of curtains,draperies,fabric hangings and similar combustible decorative material suspended from walls or ceilings shall not exceed 75 percent of the aggregate wall area where the building is equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1,and where the material is installed in accordance with Section 803.15 of the International Building Code.2.In Group R-2 dormitories,within sleeping units and dwelling units, the permissible amount of curtains,draperies,fabric hangings and similar decorative materials suspended from walls or ceilings shall not exceed 50 percent of the aggregate wall areas where the building is equipped throughout with an approved automatic sprinkler system installed in accordance with Section 903.3.1.3.In Group B and M occupancies,the amount of combustible fabric partitions suspended from the ceiling and not supported by the floor shall comply with Section 807.3 and shall not be limited.4.The 10-percent limit shall not apply to curtains,draperies,fabric hangings and similar combustible decorative materials used as window coverings. Inspector:JEFF SIEBEL-Comments:Remove Plastic Sheet hanging from ceiling in dining room or provide documentation that the material meets NFPA standards for flammability and smoke spread. Location: Dining room Printed on 08/03/2023 @ 12:54 Page 6of8 STATUS CODE DESCRIPTION FAIL 904.13.5.2-Extinguishing Automatic fire-extinguishing systems shall be serviced not less frequently than every system service. six months and after activation of the system. Inspection shall be by qualified individuals,and a certificate of inspection shall be forwarded to the fire code official upon completion. Inspector:JEFF SIEBEL-Comments:Provide current semi-annual kitchen hood fire suppression system inspection report with all discrepancies corrected.Contractor must upload online to the compliance engine.Currently 923 days past due. Must complete in 2 weeks in order to keep cooking. Location:Ansul System FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions:1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments:Provide annual service for fire extinguishers.Last serviced 2020 Location:Not Provided GENERAL NOTES JEFF SIEBEL-08/03/2023 @ 09:08 annual inspection$80 JEFF SIEBEL-08/03/2023 @ 09:10 Obtain Fire Suppression inspection report with all discrepancies corrected by 8/16/23 to continue cooking. JEFF SIEBEL-08/03/2023 @ 09:10 Provide all other corrections to avoid progressive re-inspection fees beginning at$100 REINSPECTION DATE 08/23/2023 Printed or 08/03/2023 @ 12:54 Page 7 of 8 CONTACT SIGNATURE Jian Li Signed on:08/03/2023 @ 09:54 c L G w INSPECTOR SIGNATURE JEFF SIEBEL Signed on:08/03/2023 @ 09:54 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed or 08iO3t2023 @ 12:54 Page 8of8