COMMERCIAL INSPECTION-2108 KIMBALL AVE- 8-2-23 FOR BILLING INQUIRY: (319)291-4323
Description I Total Price J
INSPECTION 2,000 $70.00
OCCUPANCY FEE $10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES
9577 08/10/2023 09/15/2023 2024-00000086 $80.00
Less Prepayment $0.00
Total Due $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
CA611
ptEAG
WATERLOO FIRE RESCUE ,
INSPECTION REPORT ! .�
EAST CHINA,2108 KIMBALL AVE,BLDG 2108 KIMBALL AVE,WATERLOO/A 50702
DETAILS
Inspection Date:08/02/2023 1 Inspection Type:Annual Inspection(1Yr) Inspection Number:4757 l Shift: N/A Station: N/A
Unit: N/A Lead Inspector:JEFF SIEBEL Other Inspectors: N/A Fee:$80.00
STATUS CODE DESCRIPTION
FAI L 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained
free from obstructions or impediments to full instant use in the case of fire or other
emergency where the building area served by the means of egress is occupied.An
exit or exit passageway shall not be used for any purpose that interferes with a
means of egress.
.,k„
Inspector:JEFF SIEBEL-Comments:Remove all storage and screen door or remove 3
exit signs and properly contain wiring.
Location: Back Hall
q
FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance
illumination. with Sections 1008.3 and 1104.5.1.
Inspector:JEFF SIEBEL-Comments:repair egress light in dining room.
Location: Dining room
FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments:Repair all exit lights in back hall and remove all
P p g
storage shelves and storage OR remove exit signs and properly contain all electrical
connections.
.40
Location: Back Hall
FAIL 304.3.1 -Spontaneous Materials susceptible to spontaneous ignition,such as oily rags,shall be stored in a
ignition. listed disposal container.Contents of such containers shall be removed and
disposed of daily.
Printed on 08/03/2023 @ 12:54
Page 1 of 8
STATUS CODE DESCRIPTION
Inspector:JEFF SIEBEL-Comments:Provide an approved listed oily waste receptacle
with self closing lid for all oily waste rags.See attached page.
Location: Not Provided
FAIL 305.1 -Clearance from Clearance between ignition sources,such as luminaires,heaters,flame-producing
ignition sources. devices and combustible materials,shall be maintained in an approved manner.
Inspector:JEFF SIEBEL-Comments: Remove storage from within 36"to furnace.
. 4 Location: back hall
.41111011
FAIL 5303.5.3-Securing Compressed gas containers,cylinders and tanks shall be secured to prevent falling
compressed gas containers, caused by contact,vibration or seismic activity.Securing of compressed gas
cylinders and tanks. containers,cylinders and tanks shall be by one of the following methods: 1.Securing
containers,cylinders and tanks to a fixed object with one or more restraints.
2.Securing containers,cylinders and tanks on a cart or other mobile device designed
for the movement of compressed gas containers,cylinders or tanks.3. Nesting of
#t' tt compressed gas containers,cylinders and tanks at container filling or servicing
facilities or in sellers'warehouses not open to the public.Nesting shall be allowed
#, � provided that the nested containers,cylinders or tanks,if dislodged,do not obstruct
_ the required means of egress.4.Securing of compressed gas containers,cylinders
.
' L►''s and tanks to or within a rack,framework,cabinet or similar assembly designed for
," s .,, ft such use. Exception:Compressed gas containers,cylinders and tanks in the process
�'* of examination,filling,transport or servicing.
m Inspector:JEFF SIEBEL-Comments:Remove compressed gas cylinder or properly
secure in upright position with CHAIN
Location:back hall shelving
Printed on 08/03/2023 @ 12:54
Page 2of8
STATUS CODE DESCRIPTION
•
FAIL 603.5-Relocatable power Multiplug adapters,such as cube adapters,unfused plug strips or any other device
taps and current not complying with NFPA 70 shall be prohibited.The construction and use of current
taps.Multiplug adapters. taps and relocatable taps shall be in accordance with NFPA 70 and this code.
Inspector:JEFF SIEBEL-Comments:Remove all kitchen appliances from power strip.
Each appliance must plug directly into wall outlet.
CLocation:dining room
:11r
FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and
shall be listed and labeled in accordance with UL 817.Extension cords and flexible
cordsshall not be affixed to structures,extended through walls,ceilings or floors,or
under doors or floor coverings,nor shall such cords be subject to environmental
damage or physical impact.Extension cords shall be used only with portable
appliances.Extension cords marked for indoor use shall not be used outdoors.
Inspector:JEFF SIEBEL-Comments:Remove extension cord from camera.Extension
cords not allowed.
Location: Dining room
FAIL 606.3.3-Cleaning. Hoods,grease-removal devices,fans,ducts and other appurtenances shall be
cleaned at intervals as required by Sections 606.3.3.1 through 606.3.3.3.
Inspector:JEFF SIEBEL-Comments:Provide current quarterly kitchen hood exhaust
system inspection report with all discrepancies corrected. Report from AKA dated
3/14/23 lists 7 discrepancies.Contractor must upload corrections online to the
compliance engine.
Location:Kitchen
Printed on 08/03/2023 @ 12:54
Page 3 of 8
STATUS CODE DESCRIPTION
FAIL 606.3.3.1 -Inspection. Hoods,grease-removal devices,fans,ducts and other appurtenances shall be
inspected at intervals specified in Table 606.3.3..1, or as approved by the fire code
official. Inspections shall be completed by qualified individuals.
Inspector:JEFF SIEBEL-Comments:Clean excessive grease and oil from hood filters.
mit ,._ ` , Replace broken and missing filters.
2 Location:ktichen
cm!° 606.3.3.2-Grease If during the inspection it is found that hoods,grease-removal devices,fans,ducts or
accumulation. other appurtenances have an accumulation of grease,such components shall be
cleaned in accordance with ANSI/IKECA C10.
. . . - ''.'TT/ Inspector:JEFF SIEBEL-Comments:Remove all excessive grease from appliances,
walls,floors, as piping etc. Must be completely cleaned before re-inspection.
g pp g- p Y p
,.......„ ,...' ...,,,. ,,„..._..,.„., ...,,,,,,,,,,..
=,. , `_ iv:.-... Location:kitchen
..1.r.,,:,,..,,,.„,, . .
f
‘,.,. .. ,
-..,,,_:,,, ,,‘,_.;--.,:ta.... ,
,_.._ _ _Hts,..k,_,..._...,4, %-41-2 . ,--
3'
-p F' '3Y
a.
ey
!_ f �
Printed or 08/03/2023 @ 12:54
Page 4 of 8
STATUS CODE DESCRIPTION
}
g
s �.
,Ie Sit g z
s
Sty ". - s_ fx�,z
f
,,,,1-14,?t,..ik, 4ftr''' (7::.:\,‘---\- c
i::,-,7i:_,'*;--,A
\ '''--'*-7,.:-':,---7,-:!1,4", ''.',,„-._;-5.i .,_'-'
+� 3
r ii54
va41+
I
Printed on 08iO3i2023 @ 12:54
Page5of8
STATUS CODE DESCRIPTION
FAIL 704.1 -Maintaining Where required when the building was originally constructed, materials and systems
protection. used to protect joints and voids in the following locations shall be maintained.The
materials and systems shall be securely attached to or bonded to the adjacent
construction,without openings visible through the construction. 1.Joints in or
between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or
roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a
horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a
horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a
nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the
intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the
intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.
Unprotected joints and voids do not need to be protected where such joints and
voids were not required to be protected when the building was originally
constructed.Where the system design number is known,the system shall be
inspected to the listing criteria and manufacturer's installation instructions.
Inspector:JEFF SIEBEL-Comments:Replace missing ceiling tile.
Location: Back Hall and kitchen
FAIL 807.2-Combustible In Groups A,B, E, I,M and R-1 and in dormitories in Group R-2,curtains,draperies,
decorative materials. fabric hangings and other similar combustible decorative materials suspended from
walls or ceilings shall comply with Section 807.3 and shall not exceed 10 percent of
the specific wall or ceiling area to which such materials are attached.Fixed or
movable walls and partitions, paneling,wall pads and crash pads applied structurally
or for decoration,acoustical correction,surface insulation or other purposes shall be
considered to be interior finish,shall comply with Section 803 and shall not be
considered decorative materials or furnishings. Exceptions: 1.In auditoriums in
Group A,the permissible amount of curtains,draperies,fabric hangings and similar
combustible decorative material suspended from walls or ceilings shall not exceed 75
percent of the aggregate wall area where the building is equipped throughout with
an approved automatic sprinkler system in accordance with Section 903.3.1.1,and
where the material is installed in accordance with Section 803.15 of the International
Building Code.2.In Group R-2 dormitories,within sleeping units and dwelling units,
the permissible amount of curtains,draperies,fabric hangings and similar decorative
materials suspended from walls or ceilings shall not exceed 50 percent of the
aggregate wall areas where the building is equipped throughout with an approved
automatic sprinkler system installed in accordance with Section 903.3.1.3.In Group B
and M occupancies,the amount of combustible fabric partitions suspended from the
ceiling and not supported by the floor shall comply with Section 807.3 and shall not
be limited.4.The 10-percent limit shall not apply to curtains,draperies,fabric
hangings and similar combustible decorative materials used as window coverings.
Inspector:JEFF SIEBEL-Comments:Remove Plastic Sheet hanging from ceiling in
dining room or provide documentation that the material meets NFPA standards for
flammability and smoke spread.
Location: Dining room
Printed on 08/03/2023 @ 12:54
Page 6of8
STATUS CODE DESCRIPTION
FAIL 904.13.5.2-Extinguishing Automatic fire-extinguishing systems shall be serviced not less frequently than every
system service. six months and after activation of the system. Inspection shall be by qualified
individuals,and a certificate of inspection shall be forwarded to the fire code official
upon completion.
Inspector:JEFF SIEBEL-Comments:Provide current semi-annual kitchen hood fire
suppression system inspection report with all discrepancies corrected.Contractor
must upload online to the compliance engine.Currently 923 days past due. Must
complete in 2 weeks in order to keep cooking.
Location:Ansul System
FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10. Exceptions:1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall be
allowed to be once every 3 years for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1.Electronic monitoring
shall confirm that extinguishers are properly positioned,properly charged and
unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring
device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a
building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices
and supervisory circuits shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at the
frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be
permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments:Provide annual service for fire extinguishers.Last
serviced 2020
Location:Not Provided
GENERAL NOTES
JEFF SIEBEL-08/03/2023 @ 09:08 annual inspection$80
JEFF SIEBEL-08/03/2023 @ 09:10 Obtain Fire Suppression inspection report with all discrepancies corrected by 8/16/23
to continue cooking.
JEFF SIEBEL-08/03/2023 @ 09:10 Provide all other corrections to avoid progressive re-inspection fees beginning at$100
REINSPECTION DATE
08/23/2023
Printed or 08/03/2023 @ 12:54
Page 7 of 8
CONTACT SIGNATURE
Jian Li
Signed on:08/03/2023 @ 09:54 c L
G w
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:08/03/2023 @ 09:54
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed or 08iO3t2023 @ 12:54
Page 8of8