HomeMy WebLinkAbout1761 INDEPENDENCE AVE W A 7- INVOICE DATE DUE DATE INVOICE# TOTAL DUE
09/19/2023 09/26/2023 2024-00000102 $80.00
�Jl�i��t'1Lf3JJf}OfJits
S . fY if•t tf
•
4.
Customer#: 23302 Please Make Check Payable and Remit To:
City of Waterloo
A TTN: City Clerk/Accounts Receivable
K-ZAR 715 Mulberry St
1761 INDEPENDENCE AVE WATERLOO, IA 50703
WATERLOO, IA 50703
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
COMMERCIAL INSPECTION- 1761 INDEPENDENCE AVE- 8-14-23
FOR BILLING INQUIRY: (319)291-4323
LDescription
Total Price j
INSPECTION 2,000
OCCUPANCY FEE $70.00
$10.00
CUSTOMER# BILLING DATE DUE DATE INVOICE#
23302 09/19/2023 09/26/2023 2024-00000102 cxARGEs
$80.00
Less Prepayment $0.00
Total Due $80.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
WATERLOO FIRE RESCUE 4,,E.,..
41,:t ,,
INSPECTION REPORT
K-ZAk,1761 INDEPENDENCEAVE,BLD6 1761 INDEPENDENCEAVE,WATERLOO IA 50703
DETAILS
Inspection Date:08/14/2023 I Inspection Type:Annual Inspection(1Yr) j Inspection Number:8602 Shift: N/A Station: N/A i
Unit: N/A Lead Inspector:JEFF SIEBEL j Other Inspectors: N/A
STATUS CODE DESCRIPTION
FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The
system shall be capable of powering the required load for a duration of not less than
90 minutes.
Inspector:JEFF SIEBEL-Comments:repair exit/egress light
Location: Front entrance
FAIL 505.1 -Address identification. New and existing buildings shall be provided with approved address identification.
The address identification shall be legible and placed in a position that is visible from
the street or road fronting the property.Address identification characters shall
contrast with their background.Address numbers shall be Arabic numbers or
alphabetical letters. Numbers shall not be spelled out. Each character shall be not
less than 4 inches(102 mm)high with a minimum stroke width of 1/2 inch(12.7 mm).
Where required by the fire code official,address identification shall be provided in
additional approved locations to facilitate emergency response.Where access is by
means of a private road and the building cannot be viewed from the public way,a
monument,pole or other sign or means shall be used to identify the structure.
Address identification shall be maintained.
Inspector:JEFF SIEBEL-Comments:address unreadable on front of building. Install
address on street side of building with minimum 4"letters of contrasting color to the
background.
Location:On front of store
FAIL 603.5-Relocatable power Multiplug adapters,such as cube adapters, unfused plug strips or any other device
taps and current not complying with NFPA 70 shall be prohibited.The construction and use of current
taps.Multiplug adapters. taps and relocatable taps shall be in accordance with NFPA 70 and this code.
Inspector:JEFF SIEBEL-Comments:properly mount power strip with screw holes on
back to wall
Location:Behind pull tab machines
Printed on 08/15/2023 @ 15:28
Page 1 of 3
STATUS CODE DESCRIPTION
FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance
with this section and NFPA 10.Exceptions: 1.The distance of travel to reach an
extinguisher shall not apply to the spectator seating portions of Group A-5
occupancies.2.Thirty-day inspections shall not be required and maintenance shall be
allowed to be once every 3 years for dry-chemical or halogenated agent portable fire
extinguishers that are supervised by a listed and approved electronic monitoring
device,provided that all of the following conditions are met:2.1.Electronic monitoring
shall confirm that extinguishers are properly positioned,properly charged and
unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring
device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a
building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices
and supervisory circuits shall be tested every 3 years when extinguisher maintenance
is performed.2.5.A written log of required hydrostatic test dates for extinguishers
shall be maintained by the owner to verify that hydrostatic tests are conducted at the
frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be
permitted to be located at staff locations.
Inspector:JEFF SIEBEL-Comments: Provide annual service for fire extinguishers
Location: Not Provided
GENERAL NOTES
JEFF SIEBEL-08/15/2023 @ 14:29 annual inspection$80
REINSPECT/ON DATE
09/05/2023
CONTACT SIGNATURE
Muhammad AAmir
Signed on:08/15/2023 @ 14:25
INSPECTOR SIGNATURE
JEFF SIEBEL
Signed on:08/15/2023 @ 14:25
Printed on 08/15/2023 @ 15:28
Page 2 of 3
QUESTIONS ABOUT YOUR INSPECTION?
JEFF SIEBEL
Jeff.Siebel@Waterloo-ia.org
3192301224
Printed on 08/15/2023 @ 15:28
Page 3of3