Loading...
HomeMy WebLinkAbout1761 INDEPENDENCE AVE W A 7- INVOICE DATE DUE DATE INVOICE# TOTAL DUE 09/19/2023 09/26/2023 2024-00000102 $80.00 �Jl�i��t'1Lf3JJf}OfJits S . fY if•t tf • 4. Customer#: 23302 Please Make Check Payable and Remit To: City of Waterloo A TTN: City Clerk/Accounts Receivable K-ZAR 715 Mulberry St 1761 INDEPENDENCE AVE WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1761 INDEPENDENCE AVE- 8-14-23 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price j INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# 23302 09/19/2023 09/26/2023 2024-00000102 cxARGEs $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE 4,,E.,.. 41,:t ,, INSPECTION REPORT K-ZAk,1761 INDEPENDENCEAVE,BLD6 1761 INDEPENDENCEAVE,WATERLOO IA 50703 DETAILS Inspection Date:08/14/2023 I Inspection Type:Annual Inspection(1Yr) j Inspection Number:8602 Shift: N/A Station: N/A i Unit: N/A Lead Inspector:JEFF SIEBEL j Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. Inspector:JEFF SIEBEL-Comments:repair exit/egress light Location: Front entrance FAIL 505.1 -Address identification. New and existing buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be not less than 4 inches(102 mm)high with a minimum stroke width of 1/2 inch(12.7 mm). Where required by the fire code official,address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way,a monument,pole or other sign or means shall be used to identify the structure. Address identification shall be maintained. Inspector:JEFF SIEBEL-Comments:address unreadable on front of building. Install address on street side of building with minimum 4"letters of contrasting color to the background. Location:On front of store FAIL 603.5-Relocatable power Multiplug adapters,such as cube adapters, unfused plug strips or any other device taps and current not complying with NFPA 70 shall be prohibited.The construction and use of current taps.Multiplug adapters. taps and relocatable taps shall be in accordance with NFPA 70 and this code. Inspector:JEFF SIEBEL-Comments:properly mount power strip with screw holes on back to wall Location:Behind pull tab machines Printed on 08/15/2023 @ 15:28 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10.Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEFF SIEBEL-Comments: Provide annual service for fire extinguishers Location: Not Provided GENERAL NOTES JEFF SIEBEL-08/15/2023 @ 14:29 annual inspection$80 REINSPECT/ON DATE 09/05/2023 CONTACT SIGNATURE Muhammad AAmir Signed on:08/15/2023 @ 14:25 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:08/15/2023 @ 14:25 Printed on 08/15/2023 @ 15:28 Page 2 of 3 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 08/15/2023 @ 15:28 Page 3of3