Loading...
HomeMy WebLinkAbout4550 LA PORTE RD W 4 INVOICE DATE DUE DATE INVOICE# TOTAL DUE 09/19/2023 09/26/2023 2024-00000113 $100.00 • 1,,...._ U Customer#: 15249 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BAMBOO RIDGE CAMPGROUND 715 Mulberry St 4550 HESS RD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION -4550 LA PORTE RD - 8-22-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 15249 09/19/2023 09/26/2023 2024-00000113 $100.00 Less Prepayment $0.00 Total Due— $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. ,i3u\C\ �p,TER��O WATERLOO FIRE RESCUE INSPECTION REPORT BAMBOO RIDGE,4550 LA PORTE RD,BLDG 4550 LA PORTE ROAD,WATERLOO L4 50702 DETAILS Inspection Date:08/22/2023 Inspection Type:Annual Inspection(1Yr) ! Inspection Number:9172 j Shift: N/A Station: N/A Unit: N/A Lead Inspector:JEFF SIEBEL j Other Inspectors: N/A j Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:unable to test emergency lights.provide test and repair documentation with a signature and date. Location:Upper women's restroom FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEFF SIEBEL-Comments:One lamp on egress light not working.Provide documentation of repair with signature and date. Location: Lower Men's restroom by shower FAIL 507.5.3-Private fire service Private fire service mains and water tanks shall be periodically inspected,tested and mains and water tanks. maintained in accordance with NFPA 25 at the following intervals: 1.Private fire hydrants of all types:Inspection annually and after each operation;flow test and maintenance annually.2.Fire service main piping: Inspection of exposed,annually; flow test every 5 years.3.Fire service main piping strainers: Inspection and maintenance after each use.Records of inspections,testing and maintenance shall be maintained. Inspector:JEFF SIEBEL-Comments:Provide current annual private fire hydrant inspection report with all discrepancies corrected.Currently 23 days past due. Contractor must upload online to the compliance engine. Location:Not Provided Printed on 08/24/2023 @ 07:13 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 5303.5.3-Securing Compressed gas containers,cylinders and tanks shall be secured to prevent falling compressed gas containers, caused by contact,vibration or seismic activity.Securing of compressed gas cylinders and tanks. containers,cylinders and tanks shall be by one of the following methods: 1.Securing containers,cylinders and tanks to a fixed object with one or more restraints. 2.Securing containers,cylinders and tanks on a cart or other mobile device designed for the movement of compressed gas containers,cylinders or tanks.3. Nesting of compressed gas containers,cylinders and tanks at container filling or servicing facilities or in sellers'warehouses not open to the public.Nesting shall be allowed provided that the nested containers,cylinders or tanks, if dislodged,do not obstruct the required means of egress.4.Securing of compressed gas containers,cylinders and tanks to or within a rack,framework,cabinet or similar assembly designed for such use. Exception:Compressed gas containers,cylinders and tanks in the process of examination,filling,transport or servicing. Inspector:JEFF SIEBEL-Comments:secure compressed gas cylinders in back store room by pop rack with chain. Location:back mechanical room. FAIL 606.3.3.3-Records. Records for inspections shall state the individual and company performing the inspection,a description of the inspection and when the inspection took place. Records for cleanings shall state the individual and company performing the cleaning and when the cleaning took place.Such records shall be completed after each inspection or cleaning and maintained. Inspector:JEFF SIEBEL-Comments:Provide current semi-annual kitchen hood cleaning inspection report for auto-fry.Currently cleaning 910 days past due.Fire suppression report due 9/21/23.Contractor must upload reports online to the compliance engine. Location:kitchen in camp store FAIL 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Inspector:JEFF SIEBEL-Comments:provide documentation of dryer vent cleaning to the outside with signature and date.Report may be emailed to fire inspector. Location:All commercial and residential clothes dryers in office,shower houses, maintenance building. Printed on 08/24/2023 @ 07:13 Page 2 of 3 s • ' STATUS CODE DESCRIPTION FAIL6109.1 -General. Storage of portable LP-gas containers of 1,000 pounds(454 kg)or less,whether filled, partially filled or empty,at consumer sites or distribution points,and for resale by dealers or resellers shall comply with Sections 6109.2 through 6109.15.1.Exceptions: 1.LP-gas containers that have not previously been in LP-gas service.2.LP-gas containers at distribution plants.3.LP-gas containers at consumer sites or distribution points,which are connected for use. Inspector:JEFF SIEBEL-Comments:remove 100#L.P.cylinder from shop.Cylinder should be stored in outside location in upright position securely stabilized with chain. Location: Maintenance building GENERAL NOTES JEFF SIEBEL-08/24/2023 @ 06:39 annual inspection$100 JEFF SIEBEL-08/24/2023 @ 06:40 obstructions removed from electrical panel during inspection. REINSPECTION DATE 09/12/2023 CONTACT SIGNATURE Matt Abben �QQ Signed on:08/24/2023 @ 07:10 INSPECTOR SIGNATURE JEFF SIEBEL Signed on:08/24/2023 @ 07:11 QUESTIONS ABOUT YOUR INSPECTION? JEFF SIEBEL Jeff.Siebel@Waterloo-ia.org 3192301224 Printed on 08/24/2023 @ 07:13 Page 3 of 3