Loading...
HomeMy WebLinkAbout209 W 5TH ST 0 f W 1I . INVOICE DATE DUE DATE INVOICE# TOTAL DUE 44, t 09/19/2023 09/26/2023 2024-00000121 $100.00 O .".... _ 0 YwM.�.r.nr.1 Customer#: 4749 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable RUSSELL LAMSON BLDG 715 Mulberry St 209 W 5TH ST WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 209 W 5TH ST-9-8-23 FOR BILLING INQUIRY: (319)291-4323 Description ( Total Price REINSPECTION 1 $100.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4749 09/19/2023 09/26/2023 2024-00000121 $100.00 Less Prepayment $0.00 Total Due — $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE INSPECTION REPORT 6� ► RUSSELL-LAMSON,209 W 5TH ST,BLDG 209 W.5TH ST,WATERLOO IA 50702vp-4 DETAILS Inspection Date:09/08/2023 j Inspection Type: Residential Common Areas Inspection I Inspection Number: 10804 I Shift: N/A Station: N/A I Unit: N/A I Lead Inspector:JEREMIAH VANDYKE I Other Inspectors: N/A I Fee:$100.00 STATUS CODE DESCRIPTION FAIL 1203.4-Maintenance. Emergency and standby power systems shall be maintained in accordance with NFPA 110 and NFPA 111 such that the system is capable of supplying service within the time specified for the type and duration required. Inspector:JEREMIAH VANDYKE-Comments: Fire pump generator is OOS and is scheduled to be repaired. Location:Generators. FAIL 1203.4.3-Records. Records of the inspection,testing and maintenance of emergency and standby power systems shall include the date of service, name of the servicing technician,a summary of conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken.Such records shall be maintained. Inspector:JEREMIAH VANDYKE-Comments: Report needed for generators service report. Location: Not Provided FAIL 1203.4.4-Switch Emergency and standby power system transfer switches shall be included in the maintenance. inspection,testing and maintenance schedule required by Section 1203.4.2.Transfer switches shall be maintained free from accumulated dust and dirt.Inspection shall include examination of the transfer switch contacts for evidence of deterioration. When evidence of contact deterioration is detected,the contacts shall be replaced in accordance with the transfer switch manufacturer's instructions. Inspector:JEREMIAH VANDYKE-Comments:Records needed of confirmed weekly runs times/transfer switch. Dave R. maintenance manager will talk with Generator contractors on how to record and track proper operating of generators. Location: Not Provided Printed on 09/08/2023 @ 14:42 Page 1 of 4 STATUS CODE DESCRIPTION FAIL 1203.5-Operational Emergency power systems,including all appurtenant components,shall be inspected inspection and testing. and tested under load in accordance with NFPA 110 and NFPA 111. Exception:Where the emergency power system is used for standby power or peak load shaving,such use shall be recorded and shall be allowed to be substituted for scheduled testing of the generator set, provided that appropriate records are maintained. Inspector:JEREMIAH VANDYKE-Comments:Dave R.maintenance manager will talk with Generator contractors on how to record and track proper operating of generators. Location: Not Provided FAIL 1203.6-Supervision of Routine maintenance,inspection and operational testing shall be overseen by a maintenance and testing. properly instructed individual. Inspector:JEREMIAH VANDYKE-Comments:Records needed of confirmed weekly runs times/transfer switch. Dave R.maintenance manager will talk with Generator contractors on how to record and track proper operating of generators. Location: Not Provided FAIL 99999-Inspection Outcome Did the inspection pass or fail? Inspector:JEREMIAH VANDYKE-Comments:None Location: Not Provided GENERAL NOTES JEREMIAH VANDYKE-08/08/2023 @ 14:52 Fire Extinguishers serviced/compliant by Superior in August 2022. JEREMIAH VANDYKE-08/08/2023 @ 14:52 04/12/2023 S-(Quarterly)Fire Sprinkler CONTINENTAL FIRE SPRINKLER Reviewed Compliant JEREMIAH VANDYKE-08/08/2023 @ 14:52 03/01/2023 S-(Annual)Fire Alarm HAWKEYE ALARM Reviewed Compliant JEREMIAH VANDYKE-08/08/2023 @ 14:52 07/20/2022 S-(Annual)Fire Pump CONTINENTAL FIRE SPRINKLER Reviewed Compliant JEREMIAH VANDYKE-08/08/2023 @ 14:52 07/20/2022 S-(Annual)Standpipe CONTINENTAL FIRE SPRINKLER Reviewed Compliant Printed on 09/08/2023 @ 14:42 Page 2 of 4 GENERAL NOTES JEREMIAH VANDYKE-08/08/2023 @ 14:52 Contact Black Hawk County Dispatch of any changes for emergency 24 hour contacts in the event of an emergency at that address.Phone#319-291-2515. JEREMIAH VANDYKE-08/08/2023 @ 14:52 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-08/08/2023 @ 14:52 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-08/08/2023 @ 14:52 Contacted Stacy Long via phone call.States they have received their last bid last week for a new Generator and waiting on cooperate and upper management to make a decision. JEREMIAH VANDYKE-09/08/2023 @ 14:39 Stopped in for re inspect. Bids are out and waiting to be accepted. Discussed with manager Kathy that once a bid is accepted and repair is scheduled to contact me as soon as possible. JEREMIAH VANDYKE-09/08/2023 @ 14:40 Re inspect fee:$100.00 REINSPECTION DATE 10/08/2023 CONTACT SIGNATURE Kathy Nelson Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:09/08/2023 @ 14:41 9_0 J L— Printed on 09/08/2023 @ 14:42 Page 3 of 4 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 09/08I2023 @ 114:42 Page 4 of 4