Loading...
HomeMy WebLinkAbout3070 W AIRLINE HWY O* W 4 T A., INVOICE DATE DUE DATE INVOICE# TOTAL DUE e 09/19/2023 09/26/2023 2024-00000091 $80.00 r # � S 7V11\� Customer#: 13049 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ISLE OF CAPRI 715 Mulberry St ACCOUNTS PAYABLE WATERLOO, IA 50703 777 ISLE OF CAPRI BLVD WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 3070 W AIRLINE HWY- 9-7-23 FOR BILLING INQUIRY: (319)291-4323 LDescription ( Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 13049 09/19/2023 09/26/2023 2024-00000091 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. •AH-- -k.4 C .. 0C WATERLOO FIRE RESCUE (be os INSPECTION REPORT ;i \ tISLE OF CAPRI STORAGE,3070 W AIRLINE HWY,BLDG 3070 W AIRLINE HWY,WATERLOO IA ' E RESw— �yi 50703 DETAILS Inspection Date:09/07/2023 ; Inspection Type:Annual Inspection(1Yr) I Inspection Number: 11005 I Shift: N/A Station: N/A Unit: N/A ; Lead Inspector:JEREMIAH VANDYKE ; Other Inspectors: N/A ; Fee:$80.00 STATUS CODE DESCRIPTION FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a 1111,1,0;,,,,—,-'-' 77 / means of egress. Inspector:JEREMIAH VANDYKE-Comments:Remove chairs in front of marked exit. V1/4744844.1‘.‘%.11/4\ Location: Not Provided r s - FAIL 1203.2.15-Means of egress Emergency power shall be provided for means of egress illumination in accordance illumination. with Sections 1008.3 and 1104.5.1. Inspector:JEREMIAH VANDYKE-Comments:Exit light/egress emergency light needed with arrow pointing out of records area. Location: Records room north wall area. FAIL 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required in Section 1013.6.3.The system shall be capable of powering the required load for a duration of not less than 90 minutes. 411111 -'�-_ Inspector:JEREMIAH VANDYKE-Comments:Chairs need to be removed and exit light ,-;eAreVe:---v 0--- Of r------ .E.g needs to be repaired or replaced. V*StkliSAANS4-' Location: Not Provided - - - .. .. V Printed on 09/07/2023 @ 13:20 Page 1 of 4 6 STATUS CODE DESCRIPTION FAIL 506.1 -Where required. Where access to or within a structure or an area is restricted because of secured openings or where immediate access is necessary for life-saving or fire-fighting purposes,the fire code official is authorized to require a key box to be installed in an approved location.The key box shall be of an approved type listed in accordance with UL 1037,and shall contain keys to gain necessary access as required by the fire code official. Inspector:JEREMIAH VANDYKE-Comments:Master key will be needed for all doors and padlocks on casino side. Location:Criterion is putting in a Knox Box. FAIL 906.2-General requirements. Portable fire extinguishers shall be selected,installed and maintained in accordance with this section and NFPA 10. Exceptions: 1.The distance of travel to reach an extinguisher shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment.2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. Inspector:JEREMIAH VANDYKE-Comments:All fire extinguishers are past due and need to be serviced and tagged. Location: Not Provided FAIL 906.7-Hangers and brackets. Hand-held portable fire extinguishers,not housed in cabinets,shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer's installation instructions. 1 ah . Inspector:JEREMIAH VANDYKE-Comments:2 fire extinguisher were found not on brackets. •-$ Location: Near dock door and in records area. 1 in I_ ®_ Printed on 09/07/2023 @ 13:20 Page 2 of 4 STATUS CODE DESCRIPTION FAIL Chapter 14-Inspection, Fire alarm system tested at least annually by licensed contractor testing,and maintenance Inspector:JEREMIAH VANDYKE-Comments:Criterion is addressing fire alarm for entire building. Location: Not Provided GENERAL NOTES JEREMIAH VANDYKE-09/07/2023 @ 13:16 Criterion is maintaining the Fire Alarm and Sprinkler system for entire building. JEREMIAH VANDYKE-09/07/2023 @ 13:17 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m.If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday.If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-09/07/2023 @ 13:17 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-09/07/2023 @ 13:17 Lt.J.D.Van Dyke-jeremiah.vandyke@waterloo-ia.org-319-883-1615 JEREMIAH VANDYKE-09/07/2023 @ 13:19 Inspection Fee=$80.00 Send bill to Danny Lane-Isle of Capri 777 Isle of Capri Blvd Waterloo Iowa 50702 RE/NSPECTION DATE 10/07/2023 CONTACT SIGNATURE Danny Lane Reason for not collecting a signature: NA Printed on 09/07/2023 @ 13:20 Page 3 of 4 INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:09/07/2023 @ 11:24 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 09/07/2023 @ 13:20 Page 4 of 4