Loading...
HomeMy WebLinkAbout5-9 elk run rd W,q t INVOICE DATE DUE DATE INVOICE# TOTAL DUE = � 09/19/2023 09/26/2023 2024-00000095 $80.00 jf srf 4 • iMti./rlwnr. `. 'Fs 7V/.t1 Customer#: 11091 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable NEW STAR MART#2 715 Mulberry St 9 N ELK RUN RD WATERLOO, IA 50 703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 5-9 ELK RUN RD - 8-14-23 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price j INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 11091 09/19/2023 09/26/2023 2024-00000095 $80.00 Less Prepayment $0.00 Total Due-* $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. WATERLOO FIRE RESCUE I 4p7ER(0O INSPECTION REPORT 0 / NEWSTAR It PONY,5-9 N ELK RUN RD,BLDG 9 N ELK RUN RD,WATERLOO►A 50703 1 DETAILS Inspection Date:08/14/2023 Inspection Type:Annual Inspection(1Yr) Inspection Number: 10830 Shift: N/A Station: N/A I Unit: N/A Lead Inspector:JEREMIAH VANDYKE Other Inspectors: N/A STATUS CODE DESCRIPTION FAIL 1010.2.9-Panic and fire exit Swinging doors serving a Group H occupancy and swinging doors serving rooms or hardware. spaces with an occupant load of 50 or more in a Group A or E occupancy shall not be provided with a latch or lock other than panic hardware or fire exit hardware. Exceptions: 1.A main exit of a Group A occupancy shall be permitted to have locking devices in accordance with Section 1010.2.4, Item 2 3.2.Doors provided with panic hardware or fire exit hardware and serving a Group A or E occupancy shall be permitted to be electrically locked in accordance with Section 1010.2.12 or 1010.2.11. 3. Exit access doors serving occupied exterior areas shall be permitted to be locked in accordance with Section 1010.2.4, Item 8.4.Courtrooms shall be permitted to be locked in accordance with Section 1010.2.13, Item 3.Electrical rooms with equipment rated 1,200 amperes or more and over 6 feet(1829 mm)wide,and that contain overcurrent devices,switching devices or control devices with exit or exit access doors,shall be equipped with panic hardware or fire exit hardware.The doors shall swing in the direction of egress travel. Inspector:JEREMIAH VANDYKE-Comments:Remove dead bolt since door has Panic Hardware. Location: Back marked exit door. FAIL 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. Inspector:JEREMIAH VANDYKE-Comments:No storage allowed in marked exit path, 2, ;'r I - please remove. _ _ ;~. 2 Location: Hallway Printed on 08/14/2023 @ 16:25 Page 1 of 3 STATUS CODE DESCRIPTION FAIL 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute for permanent wiring and shall be listed and labeled in accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through walls,ceilings or floors,or under doors or floor coverings,nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. Extension cords marked for indoor use shall not be used outdoors. Inspector:JEREMIAH VANDYKE-Comments: Remove extension cord from outside of building,cannot be used at temporary wiring. Location:Outside on west wall.Orange extension cord. FAIL 603.8-Temporary wiring. Temporary The use of temporary wiring for electrical power and lighting installations shall not exceed is allowed for a period not to exceed of 90 days.Temporary wiring methods shall meet the applicable provisions of NFPA 70.Exception:Temporary wiring for electrical power and lighting installations is allowed complying with the applicable provisions of NFPA 70 is permitted during periods of construction, remodeling,repair or demolition of buildings,structures,equipment or similar activities. Inspector:JEREMIAH VANDYKE-Comments:Please remove Christmas lights. Location:Christmas lights on outside. FAIL 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the exhaust duct system of a clothes dryer shall be maintained in accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Inspector:JEREMIAH VANDYKE-Comments: Dryer Vent:ensure that the vent is completely cleaned to the outside of the building-keep a log of maintenance- person/date for both guest and hotel laundry. Location:Clothes dryer. GENERAL NOTES JEREMIAH VANDYKE-08/14/2023 @ 16:10 Fire extinguishers serviced/compliant by Superior Fire August 2023. JEREMIAH VANDYKE-08/14/2023 @ 16:23 This building/premises is technically outside of the City of Waterloo&its Fire Inspection jurisdiction.This inspection was performed on behalf of the building owner, Black Hawk County officials&WFR Fire Chiefs request.This inspection includes both addresses at this location,5 N Elk Run Rd(restaurant side)and 9 N Elk Run Rd 9 (convenience store side).Separate reports have been generated for this although billed together under 9 N Elk Run Rd. Printed on 08/14/2023 @ 16:25 Page 2 of 3 GENERAL NOTES JEREMIAH VANDYKE-08/14/2023 @ 16:24 Re-inspection dates are automatically generated 30 days out from the initial inspection. Normal operating hours for inspections&re-inspections are Monday- Friday,8:00 a.m.-5:00 p.m. If the automatically generated re-inspection date lands on a weekend,the re-inspection will typically be performed the following Monday or Tuesday. If all corrections are made before the 30 days,you can call to set up an earlier re-inspection. JEREMIAH VANDYKE-08/14/2023 @ 16:24 Re inspection fees may be assessed for subsequent re-inspections. Re-inspection fees start at$100,then$150,and$200 for all subsequent re-inspections.- JEREMIAH VANDYKE-08/14/2023 @ 16:25 Inspection Fee=$80.00 REINSPECTION DATE 09/13/2023 CONTACT SIGNATURE Nasar Akhtar Reason for not collecting a signature: NA INSPECTOR SIGNATURE JEREMIAH VANDYKE Signed on:08/14/2023 @ 16:14 QUESTIONS ABOUT YOUR INSPECTION? JEREMIAH VANDYKE jeremiah.vandyke@waterloo-ia.org No phone number available Printed on 08/14/2023 @ 16:25 Page 3 of 3