Loading...
HomeMy WebLinkAboutDUB'S PUB-1106 LA PORTE RD O F A roc• INVOICE DATE DUE DATE A tr 4�Q INVOICE# TOTAL DUE 07/24/2026 08/28/2026 2027-00000033 $80.00 m 0 mm u U • o 4. w 4s 7vtl‘ Customer#: 25009 Please Make Check Payable and Remit To: City of Waterloo ATTN.: City Clerk/Accounts Receivable DUB'S PUB 715 Mulberry St 1106 LA PORTE ROAD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 1106 LA PORTE RD-07/07/2026 I FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 OCCUPANCY FEE $70.00 $10.00 I CUSTOMER# BILLING DATE I DUE DATE INVOICE# CHARGES 25009 07/24/2026 08/28/2026 2027-00000033 $80.00 Less Prepayment $0.00 Total Due—+ $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection Report 425 E.3rd Street Dub's Pub-1106 La Porte RD,BLDG 1106 La Porte Rd,Waterloo IA 50702 INSPECTION DETAILS N� W Inspection Date Inspection Type Inspection Number 07/07/2026 Annual Inspection(1Yr) i7423 Lead Inspector Shirt Station Unit BRAD BALDWIN N/A N/A N/A Other Inspectors NIA SUMMARY OF INSPECTION 030 ® 4 @39 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN brad.baldwin@waterloo-ia.org,3192914319 07/29/2026 GENERAL NOTES BRAD BALDWIN-07/08/2026 @ 08:12 •$80 annual inspection fee BRAD BALDWIN-07/08/2026 @ 08:12 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07/08/2026 @ 08:12 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-07/08/2026 @ 08:12 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completed post inspection Wendi Wright Date: BRAD BALDWIN 07/08/2026 CHECKLISTS GENERATED ON 7/8/26, 8:20 AM 1 OF 3 Emergency Equipment Status Code Description Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:North exit-near karaoke in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign and egress lights combo that the required load for a duration of not less than 90 minutes. failed to illuminate during test Electrical Safety Sca;e Code Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Electric panel closet-near east exit prohibited.Approved covers shall be provided for all switch Comments:Provide missing outlet cover above electric panel and electrical outlet boxes. Fail 603.4.1-Labeling. Doors into electrical control panel rooms shall be marked Location:Electric panel closet-near east exit with a plainly visible and legible sign stating"ELECTRICAL Comments:Provide approved"Electric Room"permanent signage on ROOM"or similar approved wording.The disconnecting closet door,laminated paper will not be accepted. means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Extinguishers maintained in accordance with this section and NFPA 10. Comments:Provide annual service to extinguishers,currently due Exceptions:1.The distance of travel to reach an extinguisher this month shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. 2 OF 3 GENERATED ON 7/8/26, 8:20 AM Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $8O.00 Invoice Number Check Number Transaction Number N/A N/A N/A GENERATED ON 7/8/26, 8:20 AM 3 OF 3