Loading...
HomeMy WebLinkAboutKWIK STOP #3 - 1104 WASHINGTON ST DF W A INVOICE DATE DUE DATE INVOICE# TOTAL DUE r 07/24/2026 08/28/2026 2027-00000044 $150.00 • nutIIII Hell • ) 0s 7yt7♦� Customer#: 14228 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable KWIK STOP#3 715 Mulberry St 1104 WASHINGTON ST WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION - 1104 WAHSINGTON ST- FOR BILLING INQUIRY: (319)291-4323 07/16/2026 Description Total Price REINSPECTION 2 $150.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 14228 07/24/2026 08/28/2026 2027-00000044 $150.00 Less Prepayment $0.00 Total Due $150.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue �. Inspection Report 425 E.3rd Street Kwik Stop 3-1104 Washington ST,BLDG 1104 Washington St-STE A,Waterloo IA 50702 INSPECTION DETAILS Inspection Data Inspection Type � Inspection Number / 07/16/2026 Annual Inspection(1Yr) (REINSPECTION J 7 t1P`dL.�)*` 17611-R2 Lead Inspector Shift Station Unit BRAD BALDWIN N/A NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION 0 0 0 1 0 9 Passed codes Resolved violations Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 08/10/2026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-06125/2026 @ 07:06 $100 re-inspection fee,failure to complete corrections by scheduled re-inspection date of 6/24/26.Complete corrections to avoid fees at following inspections. BRAD BALDWIN-0612512026 @ 07:06 •$80 annual inspection fee BRAD BALDWIN-06/25/2026 @ 07:06 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-06/25/2026 @ 07:06 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-06/252026 @ 07:06 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-06/25/2026 @ 07:06 Non fire hazard note:NE parking lot light pole damaged,could be possible hazard to vehicles and people within potential fall zone. BRAD BALDWIN-07/16/2026 @ 13:19 $150 re-inspection fee for failure to complete corrections on scheduled 7/16126 inspection.Complete corrections to avoid fees at following inspections. SIGNATURES Contact signature Inspector signature No signature GENERATED ON 7/16/26, 1:21 PM 1 OF 7 Report completed post inspection Mohammad ILYAS Date: j___. "Z CHECKLISTS GENERATED ON 7/16/26, 1:21 PM 2 OF 7 Reinspection Status Code Description Fail 1010.2.4-Locks and latches, \J Locks and latches shall be permitted to prevent operation of Location:Front exit doors(north) doors where any of the following exist:1.Places of detention Comments:Install approved signage on main exit doors to"Remain or restraint.2.In Group I-1,Condition 2 and Group 1-2 unlocked during business hours" occupancies where the clinical needs of persons receiving care require containment or where persons receiving care Additional comments:East exit door(outward swing door)hinges pose a security threat,provided that all clinical staff can currently broken and door locked.Repairs shall be made to correct readily unlock doors at all times,and all such locks are keyed door, to keys carried by all clinical staff at all times or all clinical staff have the codes or other means necessary to operate the locks at all times.2.3.In buildings in occupancy Group A having an occupant load of 300 or less,Groups 8,F,M and S, and in places of religious worship,the main door or doors are permitted to be equipped with key-operated locking devices from the egress side provided:2.1.3.1.The locking device is readily distinguishable as locked.2.2.3.2.A readily visible durable sign is posted on the egress side on or adjacent to the door stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED."The sign shall be in letters 1 inch (25 mm)high on a contrasting background.2.3.3,3.The use of the key-operated locking device is revocable by the fire code official for due cause.3.4.Where egress doors are used in pairs,approved automatic flush bolts shall be permitted to be used,provided that the door leaf having the automatic flush bolts does not have a doorknob or surface-mounted hardware.4.5.Doors from individual dwelling or sleeping units of Group R occupancies having an occupant load of 10 or less are permitted to be equipped with a night latch,dead bolt or security chain,provided such devices are openable from the inside without the use of a key or tool.5.6.Fire doors after the minimum elevated temperature has disabled the unlatching mechanism in accordance with listed fire door test procedures.6.7.Doors serving roofs not intended to be occupied shall be permitted to be locked,preventing entry to the building from the roof.8.Other than egress courts,where occupants must egress from an exterior space through the building for means of egress,exit access doors shall be permitted to be equipped with an approved locking device where installed and operated in accordance with all of the following:8.1.The maximum occupant load shall be posted where required by Section 1004.9.Such sign shall be permanently affixed inside the building and shall be posted in a conspicuous space near all the exit access doorways.8.2.A weatherproof telephone or two-way communication system installed in accordance with Sections 1009.8.1 and 1009.8.2 shall be located adjacent to not less than one required exit access door on the exterior side.8.3.The egress door locking device is readily distinguishable as locked and shall be a key- operated locking device,8.4.A clear window or glazed door opening,not less than 5 square feet(0.46 m2)in area,shall be provided at each exit access door to determine if there are occupants using the outdoor area.8.5.A readily visible durable sign shall be posted on the interior side on or adjacent to each locked required exit access door serving the exterior area stating:"THIS DOOR TO REMAIN UNLOCKED WHEN THE OUTDOOR AREA IS OCCUPIED."The letters on the sign shall be not less than 1 inch(25.4 mm)high on a contrasting background.8.6.The occupant load of the occupied exterior area shall not exceed 300 occupants in accordance with Section 1004.9.Locking devices are permitted on doors to balconies,decks or other exterior spaces serving individual dwelling or sleeping units. 10.Locking devices are permitted on doors to balconies, decks or other exterior spaces of 250 square feet(23.23 m2)or less,serving a private office space. GENERATED ON 7/16/26, 1:21 PM 3 OF 7 Fail 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be Location:Back storage I 2nd exit continuously maintained free from obstructions or Comments:REPEAT VIOLATION:Per occupancy,2nd exit is not impediments to full instant use in the case of fire or other required and would be allowed to remove exit signage facing W 9th emergency where the building area served by the means of St.If signage not removed,all storage within exit path shall be egress is occupied.An exit or exit passageway shall not be removed that restricts path less than 36 inches. used for any purpose that interferes with a means of egress. Additional comments:Junction box containing wires shall be mounted to avoid hanging by MC Cable. ram, ' \d'k _. I ;. . 4' .t Ig: d Or - U f Fail 603.2-Abatement of unsafe conditions and electrical Location:Bathroom hand dryer hazards. Identified electrical hazards shall be abated.Identified Comments:Licensed electrician shall make necessary repairs to hazardous electrical conditions in permanent wiring shall be improperly wired hand dryer appliance.Copy of receipt from brought to the attention of the responsible code official. electrician shall be kept to show inspector. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that Additional comments:Repairs made(attachment)"IMG_4954"not constitute an electrical shock or fire hazard shall be abated compliant to electrical code.Specific electric code requirements shall be directed to City Electrical Inspector,Tim Moyer. not be used. t 4 I' x —1,will , ' .. , ' .. .// }------_ \ lin , \ . 4 OF 7 GENERATED ON 7/16/26, 1:21 PM Fail 603.2.2-Unapproved conditionsOpen electrical terminations, O Open junction boxes and open-wiring splices shall be Location:Walk-in fridge(above tea beverages) prohibited.Approved covers shall be provided for all switch Comments:Licensed electrician shall make necessary repairs to MC and electrical outlet boxes. cable exposing wires. * - " . ma's,:* - fi: ram . 1, ' et Fail 603.5.2-Application and usePower supply. 0 Relocatable power taps and current taps shall be directly Location:Below security camera counter connected to a permanently installed receptacle.Exceptions: Comments:Remove power strip plugged to another power strip,all 1.Where approved for use in a Group A occupancy or in a strips shall plug directly to permanent wall outlet meeting room in a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected Additional comments:See attachment rom 7/16126 together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. _ f 14 it y klimmil GENERATED ON 7/16/28, 1:21 PM 5 OF 7 Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Next to Monster beverage fridge behind counter ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip shall be properly mounted to avoid hanging to environmental or physical damage. by wires. Additional comments:No progress on 7116126 Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Below register counter ceilings,floors,under doors or floor coverings,or be subject Comments:Properly mount power strip,currently balanced on top of to environmental or physical damage. drink flat on its side. Additional comments:See attachment from 7116126 r/ - t 1 . 1 "� 7 z "116"'E :,;.,,.4,\\N:,; i'i y= i , HEM. 1 ��. °O m ' y 1 may.. Fail 603.9.1-Listed and labeled. Only listed and labeled portable,electric space heaters shall Location:Below security camera counter be used. Comments:Provide documentation of proper listing and labeling of commercially approved heater or remove from building.Heater currently plugged to power strip,remove from power strip Additional comments:Remove from building if not listed for commercial use. Additional Codes S.-- ; Code Description Fail 313.1-General. Fueled equipment including,but not limited to,motorcycles, Location:Near electric panels mopeds,lawn-care equipment,portable generators and Comments:Remove gas powered lawn mower from building portable cooking equipment,shall not be stored,operated or immediately. repaired within a building.Exceptions:1.Buildings or rooms constructed for such use in accordance with the International Building Code.2.Where allowed by Section 314.3.Storage of equipment utilized for maintenance purposes is allowed in approved locations where the aggregate fuel capacity of the stored equipment does not exceed 10 gallons(38 L)and the building is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1. 6 OF 7 GENERATED ON 7/16/26, 1:21 PM Po Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $150.00 Invoice Number Check Number Transaction Number N/A NIA NIA GENERATED ON 7/16/26, 1:21 PH 7 OF 7