Loading...
HomeMy WebLinkAboutLOCKE AT TOWER PARK - 4140 KIMBALL AV WA T INVOICE DATE DUE DATE INVOICE# TOTAL DUE 0� O 07/24/2026 08/28/2026 2027-00000045 $100.00 dTik • 'n • � u n u • '�- p ,S 1 tl 171 A Customer#: 23979 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable LOCKE FUNERAL TOWER PARK 715 Mulberry St 4140 KIMBALL AVE WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 4140 KIMBALL AVE- FOR BILLING INQUIRY: (319)291-4323 07/22/2026 Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23979 07/24/2026 08/28/2026 2027-00000045 $100.00 Less Prepayment $0.00 Total Due-' $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue � Inspection Report 425 E.3rd Street vo' Locke Funeral Tower Park-4140 Kimball AVE,BLDG 4140 Kimball Ave,Waterloo IA 50701 INSPECTION DETAILS inspection Date Inspection Type i��^^,,//�� Inspection Number c 100 07/22/2026 Annual Inspection(1Yr) 3g4Ci 4 r 17376 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION 0 44 0 12 ® 22 Passed codes Failed codes NIA codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 0811812026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-0712212026 @ 14:40 •$100 annual inspection fee BRAD BALDWIN-07/2212026 @ 14:41 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07/22/2026 @ 14:41 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-07/22/2026 @ 14:41 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-07122/2026 @ 15:07 8/18126 Re-inspection scheduled at 8:30 AM.Notify inspector if need to alter time/day. SIGNATURES Contact signature Inspector signature No signature Report completedeel post inspection Eric Locke Date: BRAD BALDWIN 07/22/2026 CHECKLISTS GENERATED ON 7/22/28, 3:08 PM 1 OF 5 Emergency Equipment Status Code Description Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Electrical room near FACP illumination in accordance with Sections 1008.3 and 1104.5,1, Comments:Repair or replace egress light that failed to illuminate during test. Fail 1203.4.3-Records. Records of the inspection,testing and maintenance of Location:Backup generator emergency and standby power systems shall include the date Comments:Provide documentation of 2hr load bank test with of service,name of the servicing technician,a summary of corrections to any deficiencies.Report may be email to inspector conditions noted and a detailed description of any conditions requiring correction and what corrective action was taken. Such records shall be maintained. Fire Alarm System Status Code Description Fail Chapter 14-Inspection,testing,and maintenance Fire alarm system tested at least annually by licensed Location:Fire alarm contractor Comments:Required annual inspection due 8115/26.Provide contractor's report including any deficiencies shall be uploaded to Compliance Engine. Fire Sprinkler System Sates Code Description Fail 5.2.1-Annual sprinkler system inspection Sprinklers shall be inspected at least annually by licensed Comments:Required annual inspection due 8/15126.Provide contractor contractor's report including any deficiencies shall be uploaded to Compliance Engine. Electrical Safety Status Code Description Fail 603.5.3-Installation. Relocatable power tap cords shall not extend through walls, Location:Bethany's desk ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip shall be properly mounted or supported to to environmental or physical damage. avoid hanging by wires. Additional Codes Status Code Description Fail 610.1.2-Maintenance. The lint trap,mechanical and heating components,and the Location:Clothes dryer vent exhaust duct system of a clothes dryer shall be maintained in Comments:Provide documentation of cleaning of dryer vent from accordance with the manufacturer's operating appliance to the outside of the building with signature and date. instructions to prevent the accumulation of lint or debris that Email documentation to fire inspector.Last recorded cleaning 8/30/23 prevents the exhaust of air and products of combustion. Fail 6104.1-General. The storage and handling of LP-gas and the installation and Location:Garage maintenance of related equipment shall comply with NFPA 58 Comments:Remove propane tank from inside the building. and be subject to the approval of the fire code official,except as provided in this chapter. GENERATED ON 7/22/26, 3:08 PM 2 OF 5 Fire Resistant Construction Maintenance Status Code Description Fail 704.1-Maintaining protection. Ux Where required when the building was originally constructed, Location:Kitchen hallway materials and systems used to protect joints and voids in the Comments:Install missing fire rated smoke seals on fire door frame following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.3oints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 704.1-Maintaining protection. 0 Where required when the building was originally constructed, Location:Chair storage room materials and systems used to protect joints and voids in the Comments:Replace missing ceiling tiles following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. GENERATED ON 7/22/26, 3:08 PM 3 OF 5 Fail 704.1•Maintaining protection, Where required when the building was originally constructed, Location:Crematory casket staging materials and systems used to protect joints and voids in the Comments:Install missing fire rated smoke seals on fire door frame following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or floor/ceiling assemblies and roof or rooflceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 704.1-Maintaining protection. Where required when the building was originally constructed, Location:Crematory hallway materials and systems used to protect joints and voids in the Comments:Install missing fire rated smoke seals on fire door frame following locations shall be maintained.The materials and systems shall be securely attached to or bonded to the adjacent construction,without openings visible through the construction.1.Joints in or between fire-resistance-rated walls,floors or flooriceiling assemblies and roof or roof/ceiling assemblies.2.Joints in smoke barriers.3.Voids at the intersection of a horizontal floor assembly and an exterior curtain wall.4.Voids at the intersection of a horizontal smoke barrier and an exterior curtain wall.5.Voids at the intersection of a nonfire-resistance-rated floor assembly and an exterior curtain wall.6.Voids at the intersection of a vertical fire barrier and an exterior curtain wall.7.Voids at the intersection of a vertical fire barrier and a nonfire-resistance-rated roof assembly.Unprotected joints and voids do not need to be protected where such joints and voids were not required to be protected when the building was originally constructed.Where the system design number is known,the system shall be inspected to the listing criteria and manufacturer's installation instructions. Fail 705.2.6-Testing. Horizontal and vertical sliding and rolling fire doors shall be Comments:Required annual inspection shall be completed including inspected and tested annually to confirm proper operation any deficiencies corrected.Provide documentation of inspection. and full closure.Records of inspections and testing shall be maintained. GENERATED ON 7/22/26, 3:08 PM 4 OF 5 Po Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 7/22/26, 3:68 PM 5 OF 5