Loading...
HomeMy WebLinkAboutLOUNGE BAR - 32 LAFAYETTE ST OC W q INVOICE DATE DUE DATE INVOICE# TOTAL DUE A. 07/24/2026 08/28/2026 2027-00000046 $80.00 -, t • I /MI i1 'al I ! T 0 Customer#: 24761 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable LOUNGE BAR 715 Mulberry St 32 LAFAYETTE ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 32 LAFAYETTE ST-07/16/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 24761 07/24/2026 08/28/2026 2027-00000046 $80.00 Less Prepayment $0.00 Total Due—p $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. ort3 Waterloo Fire Rescue MEI Inspection Report 425 E.3rd Street 44;°"' Lounge Bar-32 Lafayette ST,BLDG 32 Lafayette St,Waterloo IA 50703-3402 INSPECTION DETAILS Inspection Date Inspection Type ��� Inspection Number 07/16/2026 Annual Inspection(1Yr) 17525 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION 024 021 038 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 08/1112026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-0711712026 @ 13:38 •$80 annual inspection fee BRAD BALDWIN-07/17/2026 @ 13:38 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07117/2026 @ 13:38 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-07117/2026 @ 13:38 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-0711712026 @ 13:39 Corrected during 7116126 inspection:Removed LED strip lights from exterior(east side)of building.Exterior lighting shall be listed and approved for outdoor use. BRAD BALDWIN-07/20/2026 @ 08:24 Hookah equipment noted in basement.Hookah requires specific air exchange rates.Prior to usage of equipment in the building,contact Building Department and Mechanical Inspector for requirements or hire contractor for installation of equipment with permits and inspections BRAD BALDWIN-07/2012026 @ 08:25 •Request of specific time on scheduled inspection date or change of inspection date shall be made by business representative prior to scheduled inspection date.Failure to request time or change of date will result in failed inspection. SIGNATURES Contact signature Inspector signature GENERATED ON 7/20/26, 8:31 AM 1 OF 11 No signature Report completed post inspection IKE Launy Souverance(2025)Owners Son Date: BRAD BALDWIN 07/20/2026 CHECKLISTS GENERATED ON 7/20/28, 8:31 AM 2 OF 11 Means of Egress Status code Description Fail 1010.2.5-Bolt locks. Manually operated flush bolts or surface bolts are not Location:Front exit double doors permitted.Exceptions:1.On doors not required for egress in Comments:REPEAT VIOLATION:Remove slide bolt lock from door individual dwelling units or sleeping units.2.Where a pair of IMMEDIATELY. doors serves a storage or equipment room,manually operated edge-or surface-mounted bolts are permitted on the inactive leaf.3.Where a pair of doors serves an occupant load of less than 50 persons in a Group B,F or S occupancy, manually operated edge-or surface-mounted bolts are permitted on the inactive leaf.The inactive leaf shall not contain doorknobs,panic bars or similar operating hardware. 4.Where a pair of doors serves a Group B,F or S occupancy, manually operated edge-or surface-mounted bolts are permitted on the inactive leaf provided that such inactive leaf is not needed to meet egress capacity requirements and the building is equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1.The inactive leaf shall not contain doorknobs,panic bars or similar operating hardware.5.Where a pair of doors serves patient care rooms in Group I-2 occupancies,self-latching edge-or surface- mounted bolts are permitted on the inactive leaf provided that the inactive leaf is not needed to meet egress capacity requirements and the inactive leaf shall not contain doorknobs,panic bars or similar operating hardware. AA tlY • 110, Fail 1032.2-Reliability. Required exit accesses,exits and exit discharges shall be Location:Bar-South stairs continuously maintained free from obstructions or Comments:Remove the use of chain across stairway.Required impediments to full instant use in the case of fire or other egress exit paths shall be maintained clear of any obstructions at all emergency where the building area served by the means of times. egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. GENERATED ON 7/20/28, 8:31 AM 3 OF 11 Additional Codes Status Code Description Fail i011.11-Handrails. OFlights of stairways shall have handrails on each side and Location:East exterior flight of stairs shall comply with Section 1014.Where glass is used to Comments:Required handrail shall be installed by obtaining permit provide the handrail,the handrail shall comply with Section and inspection.Contact Brian Wirtz(Chief Building Inspector)for 2407 of the International Building Code.Exceptions:1.Flights inspection. of stairways within dwelling units,and flights of spiral stairways are permitted to have a handrail on one side only. 2.Decks,patios and walkways that have a single change in elevation where the landing depth on each side of the change of elevation is greater than what is required for a landing do not require handrails.3.In Group R-3 occupancies,a change in elevation consisting of a single riser at an entrance or egress door does not require handrails.4.Changes in room elevations of three or fewer risers within dwelling units and sleeping units in Group R-2 and R-3 do not require handrails. 5.Where a platform lift is in a stationary position and the floor • of the platform lift serves as the upper landing of a stairway, handrails shall not be required on the stairway,provided that all of the following criteria are met:5.1.The stairway contains • not more than two risers.5.2.A handhold,positioned horizontally or vertically,is located on one side of the stairway adjacent to the top landing.5.3.The handhold is located not less than 34 inches(864 mm)and not more than 42 inches(1067 mm)above the bottom landing of the stairway.5.4.The handhold gripping surface complies with Section 1014.3 and is not less than 4.5 inches(114 mm)in length. • /411014;;;;:igarit } GENERATED ON 7/20/26, 8:31 AM 4 OF 11 Fail 603.1.1-Equisvt ent and fixtureswiring. r .t Electrical„„„uips-;ent and fixtures All electrical equipment, Location:Upper level � wiring, is es..-rod appliances shall be tested;and listed by Comments:The installation of improper wiring(gray cord)shall be an approved ag Icy and labeled;and installed,used and corrected.Wiring shall not be used,wiring shall either be removed or maintained in ac,ordance with NFPA 70 and all instructions a licensed electrical contractor repair wiring to comply with current included as part of such listing. electrical code standards.Wiring shall not run through doorways to avoid hazard of damage to cord. ..,.. A �' °' _., „...„, w , :-,,,i 'i. e ' -•* a i: 1 1 , Me .. Ire r' - i :: li, '''i' ''':1,'i t i if kt i t f • a r ,, C 1'1 g a Fait GU'a.i-InstaliationGeneral. The desfgn,construction,installation,operation,alteration, Location:South exterior-Gas supply line repair rtrri maintenance of nonportable gas-fired appliances Comments:Gas supply line supports have deteriorated and are and systems sh. comply with the provisions of this section pulling away from the building.Supports shall be repaired or nd the:f,iternatiunal Fuel Gas Code.The design, replaced to Mechanical Code standards. c'aonsft" Lion,i- allation,o peration,alteration,repair and maintenance of.,onportable solid fuel-fired and oil-fired liquid fuel-fired:=."pliar,ces and systems shall comply with the prfa*risi its of this section and the International Mechanical C.itle,.The eonstruction and use of portable i nstallation of al I other furi.fired appliances not connected to a fixed fuel piping Cystem,other than portable internal combustion engines,oil larelr.,and other portable devices such as blow torches,melting;,ots and weed burners,shall comply with this section end;ire International Mechanical Code. 6103,1-Goretia.i. 'Mc stersw.;A^d,,andling of LP-gas and the installation and Location:Upper level-Kitchen rnairdfvs.ar.ce of related equipment shall comply with NFPA 58 Comments:Remove propane tank from being stored inside the and be subject ta:the approval of the fire code official,except building. ac.,provided ' d° chapter. Efffc''.g..cc!'E7iiirmzent 5r,:ea3 C:c,c'e Description ga3B ,2(` , +_ of egress illumination. ,g., shall be provided for means of egress Location:Bottom of front stairs ill, ordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights,very dim when tested, 5 OF 11 Electrical Safety Sta:us Code Description Fail 603.2-Abatement of unsafe conditions and electrical 0 hazards. Location:West exterior of building Identified electrical hazards shall be abated.Identified Comments:The improper wiring of christmas lighting shall be hazardous electrical conditions in permanent wiring shall be removed.Also,exterior lighting shall be listed and approved for brought to the attention of the responsible code official. outdoor use. Electrical wiring,devices,appliances and other equipment that is modified or damaged and constitutes Conditions that constitute an electrical shock or fire hazard shall be abated not be used. k- , .' ; s ,,r o a4 .. f , 4%xr. 1 t•j, G f Y 1 • �y� 1ii"•.Lie.,„...• d # ,p *A -' ¢ vt t2 a Arsi.�.. O'.4a�77(►'�'k.w ;,asa 4 f` ;dry Ys-,• -- -. R Y. Fail 603.2.2-Unapproved conditionsOpen electrical terminations. OX Open junction boxes and open-wiring splices shall be Location:Upper level-Kitchen prohibited.Approved covers shall be provided for all switch Comments:Missing cover shall be replaced. and electrical outlet boxes. ' r it, t.. ...., ,.., : „. . 1,.... ,,, ., 6-,.., .. 1 ...._ c., ,....., roi ix�'-k ja GENERATED ON 7/20/28, 8:31 AM 6 OF 11 Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Mechanical room near bar equipment shall be provided in accordance with Section Comments:Remove storage within 36 inches of electric panel and 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or maintain clear path of access at all times. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). Fail 603.4.1-Labeling. Doors into electrical control panel rooms shall be marked Location:Mechanical room near bar with a plainly visible and legible sign stating"ELECTRICAL Comments:Install permanent approved signage"Electric Room"on ROOM"or similar approved wording.The disconnecting door.Laminated paper will not be accepted. means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident.Where buildings or structures are supplied by more than one power source,markings shall be provided at each service equipment location and at all interconnected electric power production sources identifying all electric power sources at the premises in accordance with NFPA 70. Fail 603.5.2-Application and usePower supply. Relocatable power taps and current taps shall be directly Location:Bar-Near stage and south stairs connected to a permanently installed receptacle.Exceptions: Comments:Remove power strip from extension cord.Power strip 1.Where approved for use in a Group A occupancy or in a shall properly be mounted to avoid supported by wires.Power strip meeting room in a Group B occupancy,not more than five shall plug directly to a permanent outlet,daisy chained power strips relocatable power taps shall be permitted to be connected not allowed. together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Fail 603.5.2-Application and usePower supply. Relocatable power taps and current taps shall be directly Location:Upper level-Office connected to a permanently installed receptacle.Exceptions: Comments:Remove power strips daisy chained.Each power strip 1.Where approved for use in a Group A occupancy or in a shall plug directly to a permanent wall outlet. meeting room in a Group B occupancy,not more than five relocatable power taps shall be permitted to be connected together or connected to an extension cord for temporary use to supply power to electronic equipment.2.Current taps and relocatable power taps shall not be required to connect directly to a permanently installed receptacle outlet where used for 90 days or less for the purpose of testing the performance of such devices. Fail 603.5.3-Installation, Relocatable power tap cords shall not extend through walls, Location:Behind bar dart board-near front entrance ceilings,floors,under doors or floor coverings,or be subject Comments:Replace multi-plug adapter with power strip including to environmental or physical damage. manual reset switch,power strip shall be properly mounted to avoid hanging by wires. GENERATED ON 7/20/26, 8:31 AM 7 OF 11 Fail 603.5.3-Installation. ORelocatable power tap cords shall not extend through walls, Location:Bar-Above Di Booth ceilings,floors,under doors or floor coverings,or be subject Comments:Power strip shall properly be mounted to avoid to environmental or physical damage. supported by wires.Power strip shall plug directly to a permanent outlet,daisy chained power strips not allowed. Fail 603.5.3-Installation. ORelocatable power tap cords shall not extend through walls, Location:Upper level-Event space-Above couches ceilings,floors,under doors or floor coverings,or be subject Comments:Remove multi-plug adapter near duct work.Would to environmental or physical damage. approve replacing with power strip with manual reset switch, properly mounted to avoid being supported by wires. Fail 603.6-Extension cords. OExtension cords and flexible cordsshall not be a substitute Location:Bar-beer cooler for permanent wiring and shall be listed and labeled in Comments:Remove beer cooler from plugged to extension cord. accordance with UL 817.Extension cords and flexible Appliances including motors or heat producing elements shall plug cordsshall not be affixed to structures,extended through directly to a permanent outlet.Adding an outlet requires licensed walls,ceilings or floors,or under doors or floor coverings, electrical contractor to obtain permit and inspection. nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Ox Extension cords and flexible cordsshall not be a substitute Location:Bar-dart board near south stairs for permanent wiring and shall be listed and labeled in Comments:Remove cord extending through closet doorway to avoid accordance with UL 817.Extension cords and flexible hazard of damage to cord and remove extension cord.Extension cordsshall not be affixed to structures,extended through cords shall not be used as permanent wiring. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. ( Extension cords and flexible cordsshall not be a substitute Location:Upper level-Stage lights for permanent wiring and shall be listed and labeled in Comments:Remove extension cord plugged to lights bar,lights shall accordance with UL 817.Extension cords and flexible be plugged to a permanent outlet.If adding a new outlet,a licensed cordsshall not be affixed to structures,extended through electrical contractor shall obtain permit and inspection.Extension walls,ceilings or floors,or under doors or floor coverings, cords shall not be used as permanent wiring. nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. ) Li ( fi F! j � GENERATED ON 7/20/26, 8:31 AM 8 OF 11 Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. V Portable fire extinguishers shall be selected,installed and Location:Fire extinguishers maintained in accordance with this section and NFPA 10. Comments:Provide required annual service to all extinguishers, Exceptions:1.The distance of travel to reach an extinguisher currently due August 2026. shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 7/20/26, 8:31 AM 9 OF 11 Fail 906.2-General requirements. Portable fire extinguishers shall be selected,installed and Location:Upper level-Kitchen maintained in accordance with this section and NFPA 10. Comments:Class K extinguisher currently not required due to Exceptions:1.The distance of travel to reach an extinguisher kitchen appliances disconnected and not being used.If extinguisher shall not apply to the spectator seating portions of Group A-5 remains in building it shall be annually serviced or it may be removed occupancies.2.Thirty-day inspections shall not be required from building. and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. II IECIY GENERATED ON 7/20/26, 8:31 AM 10 OF 11 P® Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N►A $80.00 Invoice Number Check Number Transaction Number NIA NIA NIA GENERATED ON 7/20/28, 8:31 AM 11 OF 11