Loading...
HomeMy WebLinkAboutPRIME MART BROADWAY - 508 BROADWAY ST W 4 INVOICE DATE DUE DATE INVOICE# TOTAL DUE te 'r 07/24/2026 08/28/2026 2027-00000047 $80.00 <urr4!;; ,,f! O • • n m•n 1 In ii I • ' ' p Customer#: 20748 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable PRIME MART-BROADWAY 715 Mulberry St 508 BROADWAY ST WATERLOO, IA 50703 WATERLOO,IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION- 508 BROADWAY ST- FOR BILLING INQUIRY: (319)291-4323 07/16/2026 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 20748 07/24/2026 08/28/2026 2027-00000047 $80.00 Less Prepayment $0.00 Total Due —+ $80.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. titWaterloo Fire Rescue ': Inspection Report 425 E.3rd Street Prime Mart#5-508 Broadway ST,BLDG 508 Broadway St,Waterloo IA 50703 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 07/16/2026 Annual Inspection(1Yr) o74, 4,► 00 rf, 17433 Lead Inspector Shift Station Unit BRAD BALDWIN NIA NIA NIA Other Inspectors NIA SUMMARY OF INSPECTION 032 04 Q38 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN 0811112026 brad.baldwin@waterloo-ia.org,3192914319 GENERAL NOTES BRAD BALDWIN-07/17/2026 @ 11:27 •$80 annual inspection fee BRAD BALDWIN-07/17/2026 @ 11:27 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07117/2026 @ 11:27 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected BRAD BALDWIN-07/17/2026 @ 11:27 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. SIGNATURES Contact signature Inspector signature No signature Report completededpost ostinspection Shahid Chatdren Date: BRAD BALDWIN 07117/2026 CHECKLISTS GENERATED ON 7/17/26, 11:40 AM 1 OF 4 Additional Codes Status Code Description Fail 1018.4-Aisle accessways in Group M. An aisle accessway shall be provided on not less than one Location:Aisles side of each element within the merchandise pad.The Comments:Clear obstructions to minimum aisle width requirements minimum clear width for an aisle accessway not required to be accessible shall be 30 inches(762 mm).The required clear (30inches in width).Maintain clearances at all times. width of the aisle accessway shall be measured perpendicular to the elements and merchandise within the merchandise pad.The 30-inch(762 mm)minimum clear width shall be maintained to provide a path to an adjacent aisle or aisle accessway.The common path of egress travel shall not exceed 30 feet(9144 mm)from any point in the merchandise pad.Exception:For areas serving not more than 50 occupants,the common path of egress travel shall not exceed 75 feet(22 860 mm). General Housekeeping Status Code Description Fail 305.1-Clearance from ignition sources, Clearance between ignition sources,such as luminaires, Location:Furnace heaters,flame-producing devices and combustible materials, Comments:Remove storage within 36"of appliance.Maintain proper shall be maintained in an approved manner. clearances at all times. Electrical Safety Status Code Description Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Electric panel equipment shall be provided in accordance with Section Comments:Remove storage within 36"of panel,maintain proper 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or clearances and clear path of access at all times. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). GENERATED ON 7/17/26, 11:40 AM 2 OF 4 Portable Fire Extingusihers Status Code Description Fail 906.2-General requirements. O Portable fire extinguishers shall be selected,installed and Location:All extinguishers maintained in accordance with this section and NFPA 10. Comments:Provide annual service to extinguishers,last recorded Exceptions:1.The distance of travel to reach an extinguisher service in September 2024 shall not apply to the spectator seating portions of Group A-5 occupancies.2.Thirty-day inspections shall not be required and maintenance shall be allowed to be once every 3 years for dry-chemical or halogenated agent portable fire extinguishers that are supervised by a listed and approved electronic monitoring device,provided that all of the following conditions are met:2.1.Electronic monitoring shall confirm that extinguishers are properly positioned,properly charged and unobstructed.2.2.Loss of power or circuit continuity to the electronic monitoring device shall initiate a trouble signal.2.3.The extinguishers shall be installed inside of a building or cabinet in a noncorrosive environment. 2.4.Electronic monitoring devices and supervisory circuits shall be tested every 3 years when extinguisher maintenance is performed.2.5.A written log of required hydrostatic test dates for extinguishers shall be maintained by the owner to verify that hydrostatic tests are conducted at the frequency required by NFPA 10.3.In Group 1-3,portable fire extinguishers shall be permitted to be located at staff locations. GENERATED ON 7/17/26, 11:40 AM 3 OF 4 Eo Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N►A $80.00 Invoice Number Check Number Transaction Number N►A N/A N►A GENERATED ON 7/17/28, 11:40 AM 4 OF 4