Loading...
HomeMy WebLinkAboutBAMBOO RIDGE CAMPGROUND - 4550 LA PORTE ROAD a* W 4 . INVOICE DATE DUE DATE INVOICE# TOTAL DUE 0 07/24/2026 08/28/2026 2027-00000029 $100.00 u.,rrrrros.' f 0 • %Ill le. Lill I II•• � 0 4. 0e, 7b171� Customer#: 15249 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BAMBOO RIDGE CAMPGROUND 715 Mulberry St 4550 HESS RD WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL FIRE INSPECTION-4550 LAPORTE RD-07/15/2026 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 15249 07/24/2026 08/28/2026 2027-00000029 $100.00 Less Prepayment $0.00 Total Due—* $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue �y �'{ �� Inspection Report 425 E.3rd Street Bamboo Ridge-4550 La Porte RD,BLDG 4550 La Porte Road,Waterloo IA 50702 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 07/15/2026 Annual Inspection(1Yr) IC49 .s 4 , 21110 Lead Inspector Shift Stations Unit BRAD BALDWIN N/A N/A N/A Other Inspectors N/A SUMMARY OF INSPECTION 030 029 ® 36 Passed codes Failed codes N/A codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date BRAD BALDWIN brad.baldwin@waterloo-ia.org,3192914319 08/11/2026 GENERAL NOTES BRAD BALDWIN-07/2012026 @ 11:20 •$100 annual inspection fee BRAD BALDWIN-07120/2026 @ 11:18 •Commercial Fire Inspector-brad.baldwin@waterloo-ia.org-Work:319-291-4319(#5)-Cell:319-230-1224 BRAD BALDWIN-07/20/2026 @ 11:18 •If all corrections are made before the scheduled re-inspection date,you can call to set up an earlier re-inspection.Normal operating hours for inspections&re-inspections are Monday-Friday,9:00 a.m.-4:00 p.m.*****Re inspection fees may be assessed for subsequent re-inspections.Re- inspection fees start at$100,then$150,and$200 for all subsequent re-inspections. BRAD BALDWIN-07/20/2026 @ 11:18 •Provide corrections to avoid progressive re-inspection fees beginning at$100.Beer/Liquor application will not be signed until violations and hazards corrected SIGNATURES Contact signature Inspector signature No signatureedpost Report completed post inspection Matt Abben(2025) Date: BRAD BALDWIN 07/20/2026 CHECKLISTS GENERATED ON 7/20/26, 11:21 AM 1 OF 10 Means of Egress Status Code Description Fail 1032.2-Reliability. ORequired exit accesses,exits and exit discharges shall be Location:Gas station-Mechanical room continuously maintained free from obstructions or Comments:REPEAT VIOLATION:Remove obstructions to path of impediments to full instant use in the case of fire or other egress of exit.Maintain clear path of egress at all times. emergency where the building area served by the means of egress is occupied.An exit or exit passageway shall not be used for any purpose that interferes with a means of egress. 1,TT a w . it 1 GENERATED ON 7/20/26, 11:21 AM 2 OF 10 Emergency Equipment Status Code Description Fail 1103.9-Carbon monoxide alarmsdetection. OCarbon monoxide alarms detection shall be installed in Location:Cabins existing dwelling units and sleeping units Group 1-1,1-2,1-4 Comments:Provide document of testing,including repairs made to and R occupancies and In classrooms in Group E maintain working properly of carbon monoxide detectors in each occupancies where those units include any of the conditions cabin.Document shall include date&signature,email document to identified in Sections 915.1.2 through 915.1.6.The carbon monoxide alarms shall be installed in the locations specified inspector. in Section 915.2 and the installation shall be in accordance with Section 915.4.Exceptions:1.Carbon monoxide alarms are permitted to be solely battery operated where the code that was in effect at the time of construction did not require carbon monoxide detectors to be provided.2.Carbon monoxide alarms are permitted to be solely battery operated in dwelling units that are not served from a commercial power source.3.A carbon monoxide detection system in accordance with Section 915.5 shall be an acceptable alternative to carbon monoxide alarms. Fail 1203.2.15-Means of egress illumination. OEmergency power shall be provided for means of egress Location:Gas station-Near fountain drinks machine illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights that failed to illuminate, currently blinking red indicator light"Battery" Fail 1203.2.15-Means of egress illumination, Emergency power shall be provided for means of egress Location:Gas station-Women's bathroom illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights that failed to illuminate Fail 1203.2.15-Means of egress illumination. Ox Emergency power shall be provided for means of egress Location:Gas station-Men's bathroom illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights that failed to illuminate Fail 1203.2.15-Means of egress illumination. 0 Emergency power shall be provided for means of egress Location:Gas station-Above ATM illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights,currently blinking red indicator light"Battery" Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Gas station-Front vestibule illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights that failed to illuminate during test,currently blinking red indicator light"Battery" Fail 1203.2.15-Means of egress illumination. Ox Emergency power shall be provided for means of egress Location:Shower house(west)-Men's bathroom illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights near showers that failed to illuminate during test Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Gas station-Near laundry room illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights that failed to illuminate Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Gas station-Dining area illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights,currently blinking red indicator light"Battery" GENERATED ON 7/20/26, 11:21 AM 3 OF 10 Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Gas station-Kitchen illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights that failed to illuminate during test near back exit. Fail 1203.2.15-Means of egress illumination. Emergency power shall be provided for means of egress Location:Shower house(east)-Men's bathroom illumination in accordance with Sections 1008.3 and 1104.5.1. Comments:Repair or replace egress lights above sink that failed to illuminate during test Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Gas station-Near laundry room in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign,currently blinking red the required load for a duration of not less than 90 minutes. indicator light"Battery" Fail 1203.2.6-Exit signs. Emergency power shall be provided for exit signs as required Location:Gas station-Front main exit in Section 1013.6.3.The system shall be capable of powering Comments:Repair or replace exit sign,currently blinking red the required load for a duration of not less than 90 minutes. indicator light"battery" 4 OF 10 GENERATED ON 7/20/26, 11:21 AM Additional Codes Status Code Description Fail 507.5.3-Private fire service mains and water tanks. CG Private fire service mains and water tanks shall be Location:Private fire hydrants periodically inspected,tested and maintained in accordance Comments:Provide contractors inspection and report including any with NFPA 25 at the following intervals:1.Private fire hydrants deficiencies corrected to be uploaded to Compliance Engine.of all types:Inspection annually and after each operation; flow test and maintenance annually.2.Fire service main Inspection due as of 719/26. piping:Inspection of exposed,annually;flow test every 5 years.3.Fire service main piping strainers:Inspection and maintenance after each use.Records of inspections,testing and maintenance shall be maintained. Fail 610.1.2-Maintenance. Ox The lint trap,mechanical and heating components,and the Location:Maintenance garage exhaust duct system of a clothes dryer shall be maintained in Comments:Provide documentation of cleaning of dryer vent from the accordance with the manufacturer's operating appliance to the exterior of the building with signature and date. instructions to prevent the accumulation of lint or debris that prevents the exhaust of air and products of combustion. Email documentation to fire inspector. Fail 610.1.2-Maintenance. 0 The lint trap,mechanical and heating components,and the Location:Gas station-Laundry dryer exhaust duct system of a clothes dryer shall be maintained in Comments:Provide documentation of cleaning of dryer vent from the accordance with the manufacturer's operating instructions to prevent the accumulation of lint or debris that appliance to the exterior of the building with signature and date. prevents the exhaust of air and products of combustion. Email documentation to fire inspector. Fail 6104.1-General. OThe storage and handling of LP-gas and the installation and Location:Gas station-Exterior patio(west)storage room. maintenance of related equipment shall comply with NFPA 58 Comments:Remove propane tank from storage closet. and be subject to the approval of the fire code official,except as provided in this chapter. Fail 6104.1-General. QThe storage and handling of LP-gas and the installation and Location:Maintenance garage maintenance of related equipment shall comply with NFPA 58 Comments:Remove propane tank(see attachment)and(2)grill size and be subject to the approval of the fire code official,except propane tanks from building.Also,tanks shall be secured to avoid as provided in this chapter, tip-over hazard. P r , li 0 a t �. c. 111 ff. , it x GENERATED ON 7/20/26, 11:21 AM 5 OF 10 Fail 6107.3-Clearance to combustibles. Weeds,grass,brush,trash and other combustible materials Location:Cabins DK 19&20 shall be kept not less than 10 feet(3048 mm)from LP-gas Comments:Remove combustible materials(birds nests)from tanks. tanks or containers. f / Fail 907.2.8-Group R-1. Fire alarm systems and smoke alarms shall be installed in Location:Cabins Group R-1 occupancies as required in Sections 907.2.8.1 Comments:Provide document of testing,including repairs made to through 9072.8.1 maintain working properly of smoke detectors in each cabin. Document shall include date&signature,email document to inspector. 6 OF 10 GENERATED ON 7/20/26, 11:21 AN Electrical Safety Status Code Description Fail 603.2.2-Unapproved conditionsOpen electrical terminations. Open junction boxes and open-wiring splices shall be Location:Shower house(west) prohibited.Approved covers shall be provided for all switch and electrical outlet boxes. Comments:Replace missing exterior outlet cover near bathrooms. Fail 603.4-Working space and clearancesclearance. OA working space of not Working space around electrical Location:Gas station-Electric panels equipment shall be provided in accordance with Section Comments:Clear storage within t a of electrical equipment.Maintain 110,26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment proper clearances of equipment at all times. rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). tvi l Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Gas station-Laundry room closet equipment shall be provided in accordance with Section Comments:Remove storage within 36"of electric panels.Maintain 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or less,and Section 110.33 of NFPA 70 for electrical equipment clearances at all times. rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). GENERATED ON 7/20/26, 11:21 AM 7 OF 10 Fail 603.4-Working space and clearancesclearance. A working space of not Working space around electrical Location:Maintenance garage equipment shall be provided in accordance with Section Comments:REPEAT VIOLATION:Remove storage within 36"of 110.26 of NFPA 70 for electrical equipment rated 1,000 volts or electric panel,maintain clear path of access at all times. less,and Section 110.33 of NFPA 70 for electrical equipment rated over 1,000 volts.The minimum required working space shall be not less than 30 inches(762 mm)in width,36 inches (914 mm)in depth and 78 inches(1981 mm)in height shall be providedin front of electrical service equipment.Where the electrical service equipment is wider than 30 inches(762 mm),the minimum working space shall be not less than the width of the equipment.Storage of materials shall not be located within the designated working space.Exceptions:1. Where other dimensions are required or allowed by NFPA 70. 2.Access openings into attics or under-floor areas that provide a minimum clear opening of 22 inches(559 mm)by 30 inches(762 mm). 1 k \ \r. ' t ‘ , \ , , ;iT ;`.: 1111111"111A rd.- 8 OF 10 GENERATED ON 7/20/26, 11:21 AM Fail 603.5.3-Installation. 0 Relocatable power tap cords shall not extend through walls, Location:Gas station-IT closet ceilings,floors,under doors or floor coverings,or be subject Comments:Properly mount power strip to avoid being supported by to environmental or physical damage. wires. 411 9 / c fF/jJ I I,, Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Gas station-Kitchen for permanent wiring and shall be listed and labeled in Comments:Remove large freezer from plugged to extension cord accordance with UL 817.Extension cords and flexible and running across walkway.Extension cords shall not be used as cordsshall not be affixed to structures,extended through permanent wiring.If needing to add an outlet,licensed electrical walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or contractor shall obtain permit and inspection. physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. Extension cords and flexible cordsshall not be a substitute Location:Maintenance garage-Mechanical room for permanent wiring and shall be listed and labeled in Comments:Remove dehumidifier plugged to extension cord, accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through extension cords shall not be used as permanent wiring. walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. Fail 603.6-Extension cords. OExtension cords and flexible cordsshall not be a substitute Location:Gas station-Above beer walk-in cooler for permanent wiring and shall be listed and labeled in Comments:Remove green extension cord extending above cooler, accordance with UL 817.Extension cords and flexible cordsshall not be affixed to structures,extended through extension cords shall not be used as permanent wiring walls,ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact.Extension cords shall be used only with portable appliances.Extension cords marked for indoor use shall not be used outdoors. GENERATED ON 7/20/26, 11:21 AM 9 OF 10 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid N/A $100.00 Check Number Transaction Number Invoice Number NIA NIA NIA 10 OF 10 GENERATED ON 7/20/26, 11:21 AM