Loading...
HomeMy WebLinkAboutMARTIN REALTORS - 1010 W 4TH ST W As INVOICE DATE DUE DATE INVOICE# TOTAL DUE re 07/31/2026 09/04/2026 2027-00000019 $100.00 „rirrr4_* O • •U nu. R:'11, • 0 _ - b i tl i7N� Customer#: 20824 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable MARTIN REALTORS 715 Mulberry St 1419 W 4TH ST WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS RENTAL INSPECTION-1010 W 11TH ST-07/17/26 FOR BILLING INQUIRY: (319)291-4323 Description Total Price NO SHOW INSPECTION FEE $100.00 CUSTOMER# BILLINGi DATE DUE DATE INVOICE# CHARGES 20824 07/31/2026 09/04/2026 2027-00000019 $100.00 Less Prepayment $0.00 Total Due— $100.00 City of Waterloo Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of Administrative Services Offset Program if not paid in full within ninety days. Waterloo Fire Rescue Inspection nspection Report 425 E.3rd Street BLDG 1010 West 11th Street-1010 W 11th ST,Waterloo IA 50702-1740 INSPECTION DETAILS Inspection Date Inspection Type Inspection Number 07117/2026 2015 IPM ental Inspection REINSPECTION 4536 ' r• 22354-R1 Lead Inspector Shift Station Unit NATE BEUSELING NIA NIA N/A Other Inspectors N/A SUMMARY OF INSPECTION � 0 025 Passed codes Failed codes NEXT STEPS Please direct questions about your Inspection to: Reinspection Date NATE BEUSELING 08/17/2026 nate.beuseling@waterloo-ia.org GENERAL NOTES NATE BEUSELING-07/1712026 @ 10:34 Reinspection for property 1010 W 11th was scheduled with Manthan Patel,arrived at 9:45 and., at 10:20,reached out tb an he said that a member from the property management team would be meeting me,left inspection at 10:20 w'h no entry gai ,100.00 fee assesed NATE BEUSELING-05/1812026 @ 07:50 Was not able to check outlets in living or dining room due to tenant belongings aswell as kitchen and bedrooms,egress in house is in difficult condition due to buildup of belongings,also was not able to check all windows for function ability during inspection,recommendation is to have maintenance team make sure all windows function and lock appropriately NATE BEUSELING-05/1812026 @ 07:50 All structural repairs,water heater replacement,furnace replacement and major electrical repairs require appropriate permits and inspections. NATE BEUSELING-05/1812026 @ 07:50 Re-inspection date is as posted on the inspection report.The rental unit's responsible person/s shall contact prior to inspection date to set up time of re- inspection.If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to occupants of the unit/s.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150, and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections. NATE BEUSELING-0511812026 @ 07:50 Property Safety Inspector-nate.beuseling@waterloo-ia.org-Work:319-291-4319(#8)-Cell:319-464-5605 SIGNATURES Contact signature Inspector signature No signature Report completed post inspection GENERATED ON 7/17/26, 10:37.AM 1 OF 10 Martin Inc Realtors Date: CHECKLISTS NATE BEUSELING 07/17/2026 GENERATED ON 7/17/26, 10:37 AM 2 OF 10 Reinspection Status Code Description Fail 2015 IPMC 304.13-Window,skylight and door frames ( Every window,skylight,door and frame shall be kept in Location:Bedroom 3 clockwise sound condition,good repair and weather tight. Comments:window found to be cracked shall be repaired Fail 2015 IPMC 304.13.2-Openable windows Every window,other than a fixed window,shall be easily Location:Bedroom 3 clockwise openable and capable of being held in position by window hardware Comments:Window does not function(painted shut)shall be made to be operable again Fail 2015 IPMC 304.13.2-Openable windows Every window,other than a fixed window,shall be easily Location:Bedroom one clockwise openable and capable of being held in position by window hardware Comments:window does not open shall be made functional Fail 2015 IPMC 304.15-Doors Exterior doors,door assemblies,operator systems if Location:Front storm door provided,and hardware shall be maintained in good condition.Locks at all entrances to dwelling units and Comments:Storm door found to be in disrepair not shutting and sleeping units shall tightly secure the door.Locks on means latching as designed shall be restored to original function of egress doors shall be in accordance with Section 702.3. Fail 2015 IPMC 304.15-Doors Exterior doors,door assemblies,operator systems if Location:Front exterior door provided,and hardware shall be maintained in good Comments:Trim around door shall be painted or repaired to be made condition.Locks at all entrances to dwelling units and sleeping units shall tightly secure the door.Locks on means weather resistant of egress doors shall be in accordance with Section 702.3. fH 1 i y Fail 2015 IPMC 304.7-Roofs and drainage The roof and flashing shall be sound,tight and not have Location:Rear of property defects that admit rain,Roof drainage shall be adequate to Comments:Gutters have been removed from property shall be prevent dampness or deterioration in the walls or interior replaced with gutter system also see 302.2 Premises shall be graded portion of the structure.Roof drains,gutters and downspouts and maintained to prevent the erosion of soil and to prevent the shall be maintained in good repair and free from obstructions. accumulation of stagnant water thereon,or within any structure Roof water shall not be discharged in a manner that creates a public nuisance. located thereon GENERATED ON 7/17/26, 10:37 AM 3 OF 10 Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Kitchen maintained in good,clean and sanitary condition.Peeling, Comments:Kitchen floor worn down to subfloor shall be repaired or chipping,flaking or abraded paint shall be repaired,removed replaced or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. } t Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Stairwell to upstairs maintained ink good,clean and sanitary condition.Peeling, Comments:a step in the stairwell to the upstairs level is in disrepair chipping,flaking or abraded paint shall be repaired,removed with a nail sticking out the front of it shall be repaired or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. ' • 4 OF 10 GENERATED ON 7/17/26, 10:37 AM Fail 2015 IPMC 305,3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Stairwell to upper floor maintained in good,clean and sanitary condition.Peeling, Comments:wall paneling has staples perturbing into the stairwell chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and shall be removed other defective surface conditions shall be corrected, s x • ♦g Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Kitchen maintained in good,clean and sanitary condition.Peeling, Comments:a top cabinet door is broken to hinge shall be repaired chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Kitchen maintained in good,clean and sanitary condition.Peeling, Comments:Lower cabinet door hanging shall be secured or repaired chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. GENERATED ON 7/17/26, 10:37 AM 5 OF 10 Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Basement maintained in good,clean and sanitary condition.Peeling, Comments:Busted concrete in basement observed shall be repaired chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. Fail 2015 IPMC 305.3-Interior surfaces Interior surfaces,including windows and doors,shall be Location:Bathroom maintained in good,clean and sanitary condition.Peeling, Comments:Hole in vanity top observed shall be repaired chipping,flaking or abraded paint shall be repaired,removed or covered.Cracked or loose plaster,decayed wood and other defective surface conditions shall be corrected. Pr 4,4 6 OF 10 GENERATED ON 7/17/26, 10:37 AM Fail 2015 IPMC 402.2-Common halls and stairways Every common hall and stairway in residential occupancies, Location:Backside of property/Back door other than in one-and two-family dwellings,shall be lighted at Comments:A exterior light is required to illuminate the back stoop all times with not less than a 60-watt standard incandescent light bulb for each 200 square feet(19 m2)of floor area or and landing of the exterior stairs equivalent illumination,provided that the spacing between lights shall not be greater than 30 feet(9144 mm).In other than residential occupancies,means of egress,including exterior means of egress,stairways shall be illuminated at all times the building space served by the means of egress is occupied with not less than 1 footcandle(11 lux)at floors, landings and treads. Fail 2015 IPMC 402.2-Common halls and stairways Every common hall and stairway in residential occupancies, Location:Front of house/Front door other than in one-and two-family dwellings,shall be lighted at Comments:A light or form of illumination is required over any all times with not less than a 60-watt standard incandescent light bulb for each 200 square feet(19 m2)of floor area or external steps or landings equivalent illumination,provided that the spacing between lights shall not be greater than 30 feet(9144 mm).In other than residential occupancies,means of egress,including exterior means of egress,stairways shall be illuminated at all times the building space served by the means of egress is occupied with not less than 1 footcandle(11 lux)at floors, landings and treads. Fail 2015 IPMC 505.4-Water heating facilities Water heating facilities shall be properly installed,maintained Location:Basement and capable of providing an adequate amount of water to be drawn at every required sink,lavatory,bathtub,shower and Comments:Water heater in basement found to be installed incorrectly,cannot have pex material for the first 18 in of waterheater laundry facility at a minimum temperature of 110°F(43°C).A gas-burning water heater shall not be located in any bathroom,toilet room,bedroom or other occupied room normally kept closed,unless adequate combustion air is provided.An approved combination temperature and pressure-relief valve and relief valve discharge pipe shall be properly installed and maintained on water heaters GENERATED ON 7/17/26, 10:37 AM 7 OF 10 Fail 2015 IPMC 603.1-Mechanical appliances Mechanical appliances,fireplaces,solid fuel-burning Location:Basement appliances,cooking appliances and water heating appliances Comments:Furnace has hole in duct work covered by duct tape,shall shall be properly installed and maintained in a safe working be repaired with appropriate cover condition,and shall be capable of performing the intended function. • Fail 2015 IPMC 605.2-Receptacles Every habitable space in a dwelling shall contain not less Location:Bathroom than two separate and remote receptacle outlets.Every Comments:Receptacle found in bathroom is painted over shall be laundry area shall contain not less than one grounding-type replaced with GFCI outlet receptacle or a receptacle with a ground fault circuit interrupter.Every bathroom shall contain not less than one receptacle.Any new bathroom receptacle outlet shall have ground fault circuit interrupter protection.All receptacle outlets shall have the appropriate faceplate cover for the location. Fail 2015 IPMC 605.3-Luminaires Location:Bedroom one clockwise Every public hall,interior stairway,toilet room,kitchen, bathroom,laundry room,boiler room and furnace room shall Comments:Light fixture in room missing appropriate globe,globe contain not less than one electric luminaire.Pool and spa shall be installed luminaires over 15 V shall have ground fault circuit interrupter protection. Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1 Location:Bedroom one on left Single or multiple-station smoke alarms shall be installed and maintained in Groups R-2,R-3,R-4 and 1-1 regardless of Comments:No smoke detector present shall be added occupant load at all of the following locations:1.On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.2.In each room used for sleeping purposes.3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level 8 OF 10 GENERATED ON 7/17/26, 10:37 AM Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I.1 Single or multiple-station smoke alarms shall be installed and Location:Bedroom 2 clockwise maintained in Groups R-2,R-3,R-4 and I-1 regardless of occupant load at all of the following locations:1.On the Comments:Smoke detector missing shall be replaced ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.2.In each room used for sleeping purposes.3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1 Single or multiple-station smoke alarms shall be installed and Location:Bedroom 3 clockwise maintained in Groups R-2,R-3,R-4 and I-1 regardless of occupant load at all of the following locations:1.On the Comments:Smoke detector missing shall be replaced ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.2.In each room used for sleeping purposes.3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1 Single or multiple-station smoke alarms shall be installed and Location:Hallway outside of bedrooms maintained in Groups R-2,R-3,R-4 and I-1 regardless of occupant load at all of the following locations:1.On the Comments:Missing smoke detector shall be replaced ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.2.In each room used for sleeping purposes.3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and 1-1 Single or multiple-station smoke alarms shall be installed and Location:Main floor hallway maintained in Groups R-2,R-3,R-4 and I-1 regardless of Comments:Smoke detector in hallway outside of living room does occupant load at all of the following locations:1.On the ceiling or wall outside of each separate sleeping area in the not test shall be repaired or replaced immediate vicinity of bedrooms.2.In each room used for sleeping purposes.3.In each story within a dwelling unit, including basements but not including crawl spaces and uninhabitable attics.In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels,a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level Fail 2021 IRC R315.3-Carbon Monoxide Detection:Location Carbon monoxide alarms in dwelling units shall be installed Location:Hallway between bedrooms outside of each separate sleeping area in the immediate Comments:Co detector not functional shall be repaired or replaced vicinity of the bedrooms.Where a fuel-burning appliance is located within bedroom or its attached bathroom,a carbon monoxide alarm shall be installed within the bedroom. GENERATED ON 7/17/26, 10:37 AM 9 OF 10 tg3 Statement of Fees FEE Invoice Date Inspection Fee Date Paid Amount Paid NIA $100.00 Invoice Number Check Number Transaction Number NIA NIA NIA 10 OF 10 GENERATED ON 7/17/26, 10:37 AM