HomeMy WebLinkAboutMARTIN REALTORS - 1010 W 4TH ST W As INVOICE DATE DUE DATE INVOICE# TOTAL DUE
re 07/31/2026 09/04/2026 2027-00000019 $100.00
„rirrr4_* O
• •U nu. R:'11, •
0
_ - b
i tl i7N�
Customer#: 20824 Please Make Check Payable and Remit To:
City of Waterloo
ATTN: City Clerk/Accounts Receivable
MARTIN REALTORS 715 Mulberry St
1419 W 4TH ST WATERLOO, IA 50703
WATERLOO, IA 50702
Amount Enclosed:
DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT
KEEP THIS PORTION FOR YOUR RECORDS
RENTAL INSPECTION-1010 W 11TH ST-07/17/26 FOR BILLING INQUIRY: (319)291-4323
Description Total Price
NO SHOW INSPECTION FEE $100.00
CUSTOMER# BILLINGi DATE DUE DATE INVOICE# CHARGES
20824 07/31/2026 09/04/2026 2027-00000019 $100.00
Less Prepayment $0.00
Total Due— $100.00
City of Waterloo
Failure to pay in full debts listed herein within ninety days of the due date will result in an additional twenty-five percent
late fee applied to any outstanding balance. The delinquent account will be forwarded to Municipal Collections of
America for further collection efforts. Debts shall also be subject to collection through the Iowa Department of
Administrative Services Offset Program if not paid in full within ninety days.
Waterloo Fire Rescue Inspection nspection Report 425 E.3rd Street
BLDG 1010 West 11th Street-1010 W 11th ST,Waterloo IA 50702-1740
INSPECTION DETAILS
Inspection Date Inspection Type Inspection Number
07117/2026 2015 IPM ental Inspection REINSPECTION 4536 ' r• 22354-R1
Lead Inspector Shift Station Unit
NATE BEUSELING NIA NIA N/A
Other Inspectors
N/A
SUMMARY OF INSPECTION
� 0 025
Passed codes Failed codes
NEXT STEPS
Please direct questions about your Inspection to: Reinspection Date
NATE BEUSELING 08/17/2026
nate.beuseling@waterloo-ia.org
GENERAL NOTES
NATE BEUSELING-07/1712026 @ 10:34
Reinspection for property 1010 W 11th was scheduled with Manthan Patel,arrived at 9:45 and., at 10:20,reached out tb an he said that a member
from the property management team would be meeting me,left inspection at 10:20 w'h no entry gai ,100.00 fee assesed
NATE BEUSELING-05/1812026 @ 07:50
Was not able to check outlets in living or dining room due to tenant belongings aswell as kitchen and bedrooms,egress in house is in difficult condition
due to buildup of belongings,also was not able to check all windows for function ability during inspection,recommendation is to have maintenance team
make sure all windows function and lock appropriately
NATE BEUSELING-05/1812026 @ 07:50
All structural repairs,water heater replacement,furnace replacement and major electrical repairs require appropriate permits and inspections.
NATE BEUSELING-05/1812026 @ 07:50
Re-inspection date is as posted on the inspection report.The rental unit's responsible person/s shall contact prior to inspection date to set up time of re-
inspection.If all corrections are made before scheduled inspection,you can call to set up an earlier re-inspection.Please give the appropriate notices to
occupants of the unit/s.Owner or owner's agent must be present during the re-inspections.Failure to schedule a time on the date given or failure to keep
the scheduled inspection will result in a$100.00 fee.Re-inspection fees may be assessed for re-inspections.Re-inspection fees start at$50,then$150,
and$250 for all subsequent re-inspections.All appropriate keys to gain entry to locked units shall be readily available during re-inspections.
NATE BEUSELING-0511812026 @ 07:50
Property Safety Inspector-nate.beuseling@waterloo-ia.org-Work:319-291-4319(#8)-Cell:319-464-5605
SIGNATURES
Contact signature Inspector signature
No signature
Report completed post inspection
GENERATED ON 7/17/26, 10:37.AM 1 OF 10
Martin Inc Realtors Date:
CHECKLISTS
NATE BEUSELING 07/17/2026
GENERATED ON 7/17/26, 10:37 AM 2 OF 10
Reinspection
Status Code Description
Fail 2015 IPMC 304.13-Window,skylight and door frames
( Every window,skylight,door and frame shall be kept in Location:Bedroom 3 clockwise
sound condition,good repair and weather tight.
Comments:window found to be cracked shall be repaired
Fail 2015 IPMC 304.13.2-Openable windows
Every window,other than a fixed window,shall be easily Location:Bedroom 3 clockwise
openable and capable of being held in position by window
hardware Comments:Window does not function(painted shut)shall be made
to be operable again
Fail 2015 IPMC 304.13.2-Openable windows
Every window,other than a fixed window,shall be easily Location:Bedroom one clockwise
openable and capable of being held in position by window
hardware Comments:window does not open shall be made functional
Fail 2015 IPMC 304.15-Doors
Exterior doors,door assemblies,operator systems if Location:Front storm door
provided,and hardware shall be maintained in good
condition.Locks at all entrances to dwelling units and Comments:Storm door found to be in disrepair not shutting and
sleeping units shall tightly secure the door.Locks on means latching as designed shall be restored to original function
of egress doors shall be in accordance with Section 702.3.
Fail 2015 IPMC 304.15-Doors
Exterior doors,door assemblies,operator systems if Location:Front exterior door
provided,and hardware shall be maintained in good
Comments:Trim around door shall be painted or repaired to be made condition.Locks at all entrances to dwelling units and
sleeping units shall tightly secure the door.Locks on means weather resistant
of egress doors shall be in accordance with Section 702.3.
fH
1
i
y
Fail 2015 IPMC 304.7-Roofs and drainage
The roof and flashing shall be sound,tight and not have Location:Rear of property
defects that admit rain,Roof drainage shall be adequate to Comments:Gutters have been removed from property shall be
prevent dampness or deterioration in the walls or interior replaced with gutter system also see 302.2 Premises shall be graded
portion of the structure.Roof drains,gutters and downspouts and maintained to prevent the erosion of soil and to prevent the
shall be maintained in good repair and free from obstructions. accumulation of stagnant water thereon,or within any structure
Roof water shall not be discharged in a manner that creates a
public nuisance. located thereon
GENERATED ON 7/17/26, 10:37 AM
3 OF 10
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Kitchen
maintained in good,clean and sanitary condition.Peeling, Comments:Kitchen floor worn down to subfloor shall be repaired or
chipping,flaking or abraded paint shall be repaired,removed replaced
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
}
t
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Stairwell to upstairs
maintained ink good,clean and sanitary condition.Peeling, Comments:a step in the stairwell to the upstairs level is in disrepair
chipping,flaking or abraded paint shall be repaired,removed with a nail sticking out the front of it shall be repaired
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
'
•
4 OF 10
GENERATED ON 7/17/26, 10:37 AM
Fail 2015 IPMC 305,3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Stairwell to upper floor
maintained in good,clean and sanitary condition.Peeling,
Comments:wall paneling has staples perturbing into the stairwell
chipping,flaking or abraded paint shall be repaired,removed
or covered.Cracked or loose plaster,decayed wood and shall be removed
other defective surface conditions shall be corrected,
s x
•
♦g
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Kitchen
maintained in good,clean and sanitary condition.Peeling,
Comments:a top cabinet door is broken to hinge shall be repaired
chipping,flaking or abraded paint shall be repaired,removed
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Kitchen
maintained in good,clean and sanitary condition.Peeling,
Comments:Lower cabinet door hanging shall be secured or repaired
chipping,flaking or abraded paint shall be repaired,removed
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
GENERATED ON 7/17/26, 10:37 AM
5 OF 10
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Basement
maintained in good,clean and sanitary condition.Peeling, Comments:Busted concrete in basement observed shall be repaired
chipping,flaking or abraded paint shall be repaired,removed
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
Fail 2015 IPMC 305.3-Interior surfaces
Interior surfaces,including windows and doors,shall be Location:Bathroom
maintained in good,clean and sanitary condition.Peeling, Comments:Hole in vanity top observed shall be repaired
chipping,flaking or abraded paint shall be repaired,removed
or covered.Cracked or loose plaster,decayed wood and
other defective surface conditions shall be corrected.
Pr
4,4
6 OF 10
GENERATED ON 7/17/26, 10:37 AM
Fail 2015 IPMC 402.2-Common halls and stairways
Every common hall and stairway in residential occupancies, Location:Backside of property/Back door
other than in one-and two-family dwellings,shall be lighted at
Comments:A exterior light is required to illuminate the back stoop
all times with not less than a 60-watt standard incandescent
light bulb for each 200 square feet(19 m2)of floor area or and landing of the exterior stairs
equivalent illumination,provided that the spacing between
lights shall not be greater than 30 feet(9144 mm).In other
than residential occupancies,means of egress,including
exterior means of egress,stairways shall be illuminated at all
times the building space served by the means of egress is
occupied with not less than 1 footcandle(11 lux)at floors,
landings and treads.
Fail 2015 IPMC 402.2-Common halls and stairways
Every common hall and stairway in residential occupancies, Location:Front of house/Front door
other than in one-and two-family dwellings,shall be lighted at
Comments:A light or form of illumination is required over any
all times with not less than a 60-watt standard incandescent
light bulb for each 200 square feet(19 m2)of floor area or external steps or landings
equivalent illumination,provided that the spacing between
lights shall not be greater than 30 feet(9144 mm).In other
than residential occupancies,means of egress,including
exterior means of egress,stairways shall be illuminated at all
times the building space served by the means of egress is
occupied with not less than 1 footcandle(11 lux)at floors,
landings and treads.
Fail 2015 IPMC 505.4-Water heating facilities
Water heating facilities shall be properly installed,maintained Location:Basement
and capable of providing an adequate amount of water to be
drawn at every required sink,lavatory,bathtub,shower and Comments:Water heater in basement found to be installed
incorrectly,cannot have pex material for the first 18 in of waterheater
laundry facility at a minimum temperature of 110°F(43°C).A
gas-burning water heater shall not be located in any
bathroom,toilet room,bedroom or other occupied room
normally kept closed,unless adequate combustion air is
provided.An approved combination temperature and
pressure-relief valve and relief valve discharge pipe shall be
properly installed and maintained on water heaters
GENERATED ON 7/17/26, 10:37 AM
7 OF 10
Fail 2015 IPMC 603.1-Mechanical appliances
Mechanical appliances,fireplaces,solid fuel-burning
Location:Basement
appliances,cooking appliances and water heating appliances Comments:Furnace has hole in duct work covered by duct tape,shall
shall be properly installed and maintained in a safe working be repaired with appropriate cover
condition,and shall be capable of performing the intended
function.
•
Fail 2015 IPMC 605.2-Receptacles
Every habitable space in a dwelling shall contain not less
Location:Bathroom
than two separate and remote receptacle outlets.Every Comments:Receptacle found in bathroom is painted over shall be
laundry area shall contain not less than one grounding-type replaced with GFCI outlet
receptacle or a receptacle with a ground fault circuit
interrupter.Every bathroom shall contain not less than one
receptacle.Any new bathroom receptacle outlet shall have
ground fault circuit interrupter protection.All receptacle
outlets shall have the appropriate faceplate cover for the
location.
Fail 2015 IPMC 605.3-Luminaires Location:Bedroom one clockwise
Every public hall,interior stairway,toilet room,kitchen,
bathroom,laundry room,boiler room and furnace room shall Comments:Light fixture in room missing appropriate globe,globe
contain not less than one electric luminaire.Pool and spa shall be installed
luminaires over 15 V shall have ground fault circuit
interrupter protection.
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1 Location:Bedroom one on left
Single or multiple-station smoke alarms shall be installed and
maintained in Groups R-2,R-3,R-4 and 1-1 regardless of Comments:No smoke detector present shall be added
occupant load at all of the following locations:1.On the
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
8 OF 10
GENERATED ON 7/17/26, 10:37 AM
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I.1
Single or multiple-station smoke alarms shall be installed and Location:Bedroom 2 clockwise
maintained in Groups R-2,R-3,R-4 and I-1 regardless of
occupant load at all of the following locations:1.On the Comments:Smoke detector missing shall be replaced
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1
Single or multiple-station smoke alarms shall be installed and Location:Bedroom 3 clockwise
maintained in Groups R-2,R-3,R-4 and I-1 regardless of
occupant load at all of the following locations:1.On the Comments:Smoke detector missing shall be replaced
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and I-1
Single or multiple-station smoke alarms shall be installed and Location:Hallway outside of bedrooms
maintained in Groups R-2,R-3,R-4 and I-1 regardless of
occupant load at all of the following locations:1.On the Comments:Missing smoke detector shall be replaced
ceiling or wall outside of each separate sleeping area in the
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2015 IPMC 704.2.1.2-Groups R-2,R-3,R-4 and 1-1
Single or multiple-station smoke alarms shall be installed and Location:Main floor hallway
maintained in Groups R-2,R-3,R-4 and I-1 regardless of
Comments:Smoke detector in hallway outside of living room does
occupant load at all of the following locations:1.On the
ceiling or wall outside of each separate sleeping area in the not test shall be repaired or replaced
immediate vicinity of bedrooms.2.In each room used for
sleeping purposes.3.In each story within a dwelling unit,
including basements but not including crawl spaces and
uninhabitable attics.In dwellings or dwelling units with split
levels and without an intervening door between the adjacent
levels,a smoke alarm installed on the upper level shall suffice
for the adjacent lower level provided that the lower level is
less than one full story below the upper level
Fail 2021 IRC R315.3-Carbon Monoxide Detection:Location
Carbon monoxide alarms in dwelling units shall be installed Location:Hallway between bedrooms
outside of each separate sleeping area in the immediate
Comments:Co detector not functional shall be repaired or replaced
vicinity of the bedrooms.Where a fuel-burning appliance is
located within bedroom or its attached bathroom,a carbon
monoxide alarm shall be installed within the bedroom.
GENERATED ON 7/17/26, 10:37 AM
9 OF 10
tg3 Statement of Fees
FEE
Invoice Date Inspection Fee
Date Paid Amount Paid
NIA $100.00
Invoice Number
Check Number Transaction Number
NIA
NIA NIA
10 OF 10
GENERATED ON 7/17/26, 10:37 AM