Loading...
HomeMy WebLinkAbout515 LIME ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE Ailliki,i11\ 04/03/2018 OS/10/20188 2018-00000256 $80.00 AVMs& kiPt - %rloo No Customer#: 6750 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable 715 Mulberry St BOYS &GIRLS CLUB WATERLOO, IA 50703 515 LIME ST WATERLOO,IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS N- 515 LIME ST-3-29-18 COMMERCIAL INSPECTION 1 FOR BILLING INQUIRY: (319)291-4323 I I Total Price [Description $70.00 INSPECTION 2,000 $10.00 OCCUPANCY FEE DUE DATE INVOICE# CHARGES 6750 04/03/2018 CUSTOMER# I BILLING DATE 05/10/2018 I 2018-00000256 $80.00 Less Prepayment $0.00 Total Due---)- $80.00 City of Waterloo Commercial Fire Inspection Report Inspection Number 1374 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Chris Ferguson Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)493-1025 Email:chris.ferguson@waterloo-ia.org File Upload Address* 515 Lime St Business name Boys and Girls Club Inspection Date* 3/29/2018 Proprietor Boys and Girls Club Business Phone 319-234-2839 Email* bryan@cedarvalleyclubs.org Email 2 Property Owner Emergency Contact Bryan Burton Information Phone 319-234-2839 Violations Ref# CODE Violation &Location Corrected 1 [Staff Breakroom]2015 IFC: Section 605.7 Appliances-Electrical appliances...shall be maintained in accordance with all instructions included...Coffee maker was found to be plugged into portable power tap during inspection. Item was corrected on site during inspection. 2 [Staff Breakroom]2015 IFC: Section 605.4.2 Power Supply- Relocatable power taps shall be directly connected to a permanently installed receptacle. During inspection several power taps were found to be"daisy chained"together. Corrective action: All relocatable power taps shall be plugged directly into a wall outlet and not into another power tap or extension cord. Ref# CODE Violation&Location Corrected 3 [Staff Breakroom]2015 IFC:Section 605.7 Appliances- Electrical appliances...shall be maintained in accordance with all instructions included... Full sized refrigerator was found to be plugged into a relocatable power tap during inspection. Corrective action: Refrigerator shall be plugged directly into a permanent wall outlet not power tap or extension cord. 4 [Staff offices]2015 IFC: Section 605.10.4 Prohibited areas- Portable, electric space heaters shall not be operated within 3 feet of any combustible materials. On day of inspection portable space heater was found with numerous combustible items located within 3 feet of heater. Corrective action: heater was removed by staff on site. 5 [Teen Center]2015 IFC: Section 605.4.2 Power Supply- Relocatable power taps shall be directly connected to a permanently installed receptacle. During inspection several power taps were found to be"daisy chained"together near television area. Corrective action:All relocatable power taps shall be plugged directly into a wall outlet and not into another power tap or extension cord. 6 [Teen Center]2015 IFC: Section 703.2.3 Door Operation-Swinging fire doors shall close and latch from the full-open position and latch automatically. Fire door exiting from teen center to the exit stairway did not close and latch.Corrective action: provide corrective repair/replacement to ensure door will close and latch automatically. 7 [Teen Center]2015 IFC: Section 1010:1.2.1 Direction of swing- Pivot or side-hinged doors shall swing in the direction of egress travel where serving a room or area containing an occupant load of 50 or more persons... The double doors leading into the center swung into the room. Room size was roughly calculated at 36'x36' using ceiling tiles, placing the occupant load over 50. Corrective action: Provide corrective repair so that doors will swing in the direction of egress travel. 8 [IT room off of Teen Center]2015 IFC Section 605.6 Unapproved conditions-Open junction boxes and open-wiring splices shall be prohibited. Open-wiring splice was noted involving mechanical equipment above. Corrective action: ensure open splices are corrected by a qualified electrician. 9 [Dance Studio]2015 IFC: Section 703.1 Maintenance-Ceiling tiles were found to be missing from the dance studio. Corrective action: replace missing ceiling tiles. 10 [Cafeteria]2015 IFC: Section 605.7 Appliances-Electrical appliances...shall be maintained in accordance with all instructions included... Electric window air conditioner was found to be plugged into an extension cord.The manufacturer had stamped onto plug that it must plugged into permanent outlet. Corrective action: ensure window air conditioner is plugged directly into permanent wall outlet. 11 [2nd Floor]2015 IFC: Section 703.1 Maintenance-Several areas were found to have missing ceiling tiles. Staff stated this was due to ongoing work on the building's i-NAC system.All ceiling tiles should be replaced upon the completion of l-NAC work. Ref# CODE Violation &Location Corrected 12 [2nd Floor Storage Room]2015 IFC: Section 315.3.1 Ceiling Clearance-Storage shall be maintained 2 feet or more below the ceiling in non-sprinklered buildings. Storage was found within 2 feet of the ceiling on day of inspection. Corrective action:ensure that the top of storage items is not located within 2 feet of the ceiling. 13 [2nd Floor Storage Room]2015 IFC: Section 703.1 Maintenance-A large hole was found in the ceiling in the storage room area. Corrective action: repair hole found in ceiling of storage room. 14 [Exit stairway by front desk]2015 IFC: Section 703.2.3 Door Operation-Swinging fire doors shall close and latch from the full- open position and latch automatically. Fire door exiting from the second floor to the front desk area did not close and latch. Corrective action: provide corrective repair/replacement to ensure door will close and latch automatically. 15 2015 IFC: Section 901.6 Inspection,testing, and maintenance- Fire detection,alarm. and extinguishing system...shall be maintained in an operative condition at all times. Several fire protection systems were found to be out of compliance with required testing and maintenance. Please provide testing and inspection reports for review during re-inspection of the following items: a.Annual inspection of fire alarm systems with any deficiencies corrected b. Semi-annual hood cleaning and inspection report c. Semi-annual hood suppression system inspection report Comments: Please have violations corrected or a plan of correction in placed by the re- inspection date listed below to avoid any additional re-inspection fees. Feel free to contact me with any additional questions cr concerns you may have.Thank you for your time and cooperation. If violations noted during the inspection are not corrected by the given re-inspection date,additional fees are as follows: $100.00-First Re-inspection I$150.00-Second Re-inspection I$200 -Third and subsequent Re-inspections Reports Reports Fire Extinguisher Service Comment Proshield-May of 2017.All extinguishers were found to be tagged current and gauges were in the green. Inspection Fee $ 70.00 Occupancy Fee $ 10.00 Re-inspection Fee $ Total Fee* $ 80.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload (for long inspections) ReiDSpBCtioD pm-inspection# Date Time 1 5/3/2018 10:00em