Loading...
HomeMy WebLinkAbout1931 SEARS INVOICE DATE DUE DATE INVOICE# TOTAL DUE / irtia, �rw; 02/08/2018 03/12/2018 2018-00000134 $80.00 _ai dare p;.‘ Customer#: 22165 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable TOKYO BAY 715 Mulberry St 1931 SEARS WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1931 SEARS - 1-16-18 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# • CHARGES 22165 02/08/2018 03/12/2018 2018-00000134 $80.00 Less Prepayment $0.00 Total Due—> $80.00 City of Waterloo Commercial Fire Inspection Report Inspection Number 1200 Prior Inspection 684 Number Fill this field if it is available, it will auto-fill business name and address. Inspector* Jeff Siebel Waterloo Fire Rescue 715 Mulberry Street Waterloo, IA 50703 Phone(319)-230-1224 Fax. (319)-291-4262 Email:Jeff.Siebel@waterloo-ia.org File Upload Address* 1931 Sears Business name Tokyo Bay Inspection Date* 1/16/2018 Proprietor Anna Nouyen Business Phone 319-433-0999 Email* tokyowaterloo@yahoo.com Email 2 Property Owner Anna Nouyen Emergency Contact Anna Nouyen Information Phone 319-464-6106 Violations Ref# CODE Violation &Location Corrected 1 NFPA 25 Provide current annual fire sprinkler system inspection/testing report with all deficiencies corrected by a contractor certified to perform work in the State of Iowa. 2 NFPA 25 Perform annual tests of private fire hydrants. The test is to be in 7.3.2 compliance with NFPA 25 7.3.2.The test will include dry barrel test, hydrants to be fully opened and water flowed to clear, confirm proper drainage, properly lubricate caps, general in 3 609.3.3.1 Provide current semi-annual kitchen hood exhaust system cleaning/inspection report with all deficiencies corrected. Ref# CODE Violation&Location Corrected 4 904.11.6. Provide current semi-annual kitchen hood fire suppression system 2 inspection/testing with all deficiencies corrected by a contractor certified to work in the State of Iowa 5 Repair light in closet by RR hanging by wires. 6 Repair light by kitchen in hall hanging by wires. 7 Reduce bags of rice storage. Maintain a minimum of 18"clearance below fire sprinkler deflector. 8 Remove storage in penthouse. Maintain a minimum of 36" clearance to electrical panels, disconnects and fire alarm panel. 9 Properly secure compressed gas cylinder to pop rack with CHAIN. 10 Remove storage from around water heater. Maintain a minimum of 36". 11 Properly maintain and use oily waste receptacle. 12 Provide access to Anna's office and outside fire sprinkler riser room and any outside storage areas. Comments: Dryer disconnected and not used. If dryer is put back in service, a dryer vent cleaning report is required. If violations noted during the inspection are not corrected by the given re-inspection date, additional fees are as follows: $100.00 -First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections Reports Reports Annual Fire Alarm Comment Hawkeye Alarm 4/17 Inspection Fee $ 70.00 Occupancy Fee S 10.00 Re-inspection Fee $ Total Fee* $ 80.00 Received By Juilianna AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload (for long inspections) Reinspection Re-inspection# Date Time 1 2/6/2018