Loading...
HomeMy WebLinkAbout1518 FLAMMANG DR INVOICE DATE DUE DATE INVOICE# TOTAL DUE Orpork. r.t. 06/20/2018 07/20/2018 2018-00000405 $80.00 Customer#: 10914 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BARNES &NOBLE 715 Mulberry St 1518 FLAMMANG DR WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1518 FLAMMANG DR- 6-14-18 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 10914 06/20/2018 07/20/2018 2018-00000405 $80.00 Less Prepayment $0.00 Total Due-+ $80.00 City of Waterloo Commercial Fire Inspection Report Inspection Number 1569 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 1518 Flammang Dr Business name Barnes&Noble+Starbucks Coffee Inspection Date* 6/14/2018 Proprietor Steve Olsson Business Phone 319-232-0475 Email* crm2168@bn.com Email 2 Property Owner Emergency Contact Information Phone Violations Ref# CODE Violation &Location Corrected 1 2015 IFC Section 1013 Exit Sign 1013.6.3 Power source. Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss, the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or an on-site generator. *Exit light at the front entrance was out when tested -Corrective action, repair or replace Exit light Ref# CODE Violation&Location Corrected • 2 2015 IFC Section 315 General Storage 315.3.1 Ceiling clearance.Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches below sprinkler head deflectors in sprinklered areas of buildings. *Storage in back office area shelves was up next to the ceiling -Corrective action, lower storage to 18 inches below sprinkler head deflectors 3 2015 IFC Section 901 General 901.6 Inspection,testing acid maintenance. Fire detection,alarm, and extinguishing systems, mechanical smoke exhaust systems, and smoke and heat vents shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. *Fire Extinguisher in Starbucks prep/storage area near sink was found to be out date on inspection tag. -Corrective action, have extinguisher inspected and brought current or replace extinguisher with current extinguisher. 4 Follow up with Fire Alarm inspector/tester/contractor about the deficiencies noted on their inspection form.They had listed that they were unable to identify 2 duct detector stations during testing. Provide documentation that they have repaired the problem 5 Please provide current annual inspection/test reports listed below -Fire Sprinkler annual report Comments: If violations noted during the inspection are not corrected by the given re-inspection date,additional fees are as follows: $100,00-First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections Reports Reports Fire Extinguisher Service Comment Received, Hawkeye Fire&Safety Co, Sept 2017 Reports Annual Fire Alarm Comment Received, Stanley Security Lic#TSO1238, 13705 26th Ave N, Plymouth, MN Follow up about deficiencies on report,duct detector Reports Annual Fire Sprinkler Comment Please provide current annual report Inspection Fee $ 70.00 Occupancy Fee $ 10.00 Re-inspection Fee $ Total Fee* S 80.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload (for long inspections) Reinspection Re-inspection# Date Time 7/5/2018