Loading...
HomeMy WebLinkAbout1945 LA PORTE RD INVOICE DATE DUE DATE INVOICE# TOTAL DUE ,1�■\���.:� 06/20/2018 07/20/2018 2018-00000409 $100.00 °terloo Customer#: 13437 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BAYMONT INN 715 Mulberry St 2141 LA PORTE RD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1945 LA PORTE RD- 6-18-18 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price J INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 13437 06/20/2018 07/20/2018 2018-00000409 $100.00 Less Prepayment $0.00 Total Due—* $100.00 City of Waterloo :Commercial Fire Inspection Report Inspection Number 1581 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 1945 La Porte Rd Business name Baymont Inn&Suites Inspection Date* 6/18/2018 Proprietor Markus Clark Business Phone 319-234-7411 Email* markuscgm@yahoo.com Email 2 Property Owner Crossroads Hotels Inc Emergency Contact Information Phone Violations Ref# CODE Violation&Location Corrected 1 2015 IFC General Requirements Section 315 General Storage 315.3.1 Ceiling clearance. Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches below sprinkler head deflectors in sprinklered areas of buildings. *Housekeeping rooms,offices and laundry room were all found to have storage up to or within 2 feet of the ceiling. *Corrective action, lower storage in all areas of the building Ref# CODE Violation&Location Corrected 2 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.3 Working space and clearance.A working space of not less than 30 inches in width,36 inches in depth and 78 inches in height shall be provided in front of electrical service equipment.Where the electrical service equipment is wider than 30 inches,the working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. *Storage was found to be within close proximity to electrical panels *Corrective action, maintain working clearance around electrical panels at all times 3 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.4 Multiplug adapters. Multiplug adapters,such as cube adapters, unfused plug strips or any other device not complying with NFPA 70 shall be prohibited. *Occupant rooms were found to have multiplug adapters in outlets, Rooms 223,222,211,209,208,206, 109, 102 *Corrective action, remove all multiplug adapters from outlets in the building 4 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures,extended through walls, ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. *An extension cord was found to be plugged into a refrigerator in an occupant room, room 111 *Corrective action, remove all extension cords being used as permanent wiring in building. Stationary appliances such as refrigerators are to be plugged directly into an outlet. 5 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.6 Unapproved conditions.Open junction boxes and open- wiring splices shall be prohibited.Approved covers shall be provided for all switch and electrical outlet boxes. *Exit light in the pool room, by the door leading outside,had a cover plate missing on it. *Corrective action, Repair the exit light/replace the cover or replace the exit light 6 2015 IFC Fire and Smoke Protection Features Section 703 Fire- Resistance-Rated Construction 703.2.3 Door operation. Swinging fire doors shall close from the full-open position and latch automatically.The door closer shall exert enough force to close and latch the door from any partially open position. *Multiple doors to occupant rooms were found to not close and latch properly. Rooms 229,222,211,203, 111, 109 *Corrective action,ensure that all fire-rated doors and doors to occupant rooms operate properly. Ref# CODE Violation&Location Corrected 7 2015 IFC Fire Protection Systems Section 901 General 901.6 Inspection,testing and maintenance. Fire detection,alarm, and extinguishing systems,mechanical smoke exhaust systems, and smoke and heat vents shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected,tested and maintained or removed. *Multiple single station smoke detectors in occupant rooms were found to have a weak signaling alarm. Rooms 211,209,208,206, 203,201, 111, 102 *Corrective action,ensure that all smoke detectors in all occupant rooms are in good working condition at all times and have strong signal/alarm 8 2015 IFC Means of Egress Section 1008 Means of Egress Illumination 1008.2 Illumination required.The means of egress serving a room or space shall be illuminated at all times that the room or space is occupied. *Egress lights in the pool area were found to be out when tested *Corrective action,'repair or replace egress lights 9 Please provide current annual inspection reports for the following: Fire Alarm Dryer exhaust cleaning *Dryer exhaust cleaning and maintenance may be performed by hotel personnel. Follow manufacturer's directions for cleaning and maintenance. Document the date,time, person performing cleaning/maintenance and signature. These reports may be emailed to the email address above Comme nts: If violations noted during the inspection are not corrected by the given re-inspection date,additional fees are as follows: $100.00-First Re-inspection I$150.00-Second Re-inspection $200-Third and subsequent Re-inspections Reports Reports Fire Extinguisher Service Comment Hawkeye Fire&Safety,3-2018 Reports Annual Fire Sprinkler Comment N/A Reports Annual Fire Alarm Comment Please provide current annual report Inspection Fee $ 90.00 Occupancy Fee S 10.00 , Re-inspection Fee S Total Fee* S 100.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload (for long inspections) Reinspection Re-inspection# Date Time 7/10/2018