Loading...
HomeMy WebLinkAbout1501 E SAN MARNAN DR INVOICE DATE DUE DATE INVOICE# TOTAL DUE /1II!I i ter; 06/04/2018 07/10/2018 2018-00000345 $610.00 c?terlo ••° Customer#: 4661 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable TARGET STORE T1792 715 Mulberry St PO BOX 111 WATERLOO, IA 50703 MINNEAPOLIS,MN 55440 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1501 E SAN MARNAN DR- 5-22-18 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price INSPECTION 100,000 $600.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4661 06/04/2018 07/10/2018 2018-00000345 $610.00 Less Prepayment $0.00 Total Due-* $610.00 City of Waterloo Commercial Fire Inspection Report Inspection Number 1493 Prior Inspection 370 Number Fill this field if it is available, it will auto-fill business name and address. Inspector* Jeff Siebel Waterloo Fire Rescue 715 Mulberry Street Waterloo, IA 50703 Phone(319)-230-1224 Fax. (319)-291-4262 Email:Jeff.Siebel@waterloo-ia.org File Upload Address* 1501 E San Marnan Business name Target Super Store Inspection Date* 5/22/2018 Proprietor Ken Van heiden Business Phone 319-226-5600 Email* Liquor.licensing@target.com Email 2 Property Owner Carol Heiman Emergency Contact Ken Van Heiden Information Phone 319-230-3434 Violations Ref# CODE Violation &Location Corrected 1 NFPA 25 1. Provide current annual fire sprinkler system inspection/testing report with all deficiencies corrected by a contractor certified to perform work in the State of Iowa. Report from Viking pump dated 6/14/17 lists discrepancies. (dry heads testing, missing • escutcheons) Provide documentation of corrections being completed. 2 609.3.3.1 Provide current semi-annual kitchen hood exhaust system cleaning/inspection report with all deficiencies corrected. Ref# CODE Violation &Location Corrected 3 NFPA 25 Perform annual tests of private fire hydrants.The test is to be in 7.3.2 compliance with NFPA 25 7.3.2. The test will include dry barrel test, hydrants to be fully opened and water flowed to clear, confirm • proper drainage, properly lubricate caps,general inspection 4 NFPA 110 Provide current annual generator test/inspection report with all and 111. discrepancies corrected. Operational emergency power systems, including all appurtenant components shall be inspected and tested under load in accordance with NFPA 110 and 111. 5 Provide annual emergency generator load bank test report. 6 Team lead office fire door to completely self-close and latch. 7 Remove electric heater from ETL office or provide documentation of proper use and clearances. 8 Repair/Replace emergency exit door and frame from employee break room. Frame is extremely rusted. Door must unlatch and swing to full open with less than 15#force . 9 Obtain final inspection for new cooler/freezers. 10 Replace loose fire sprinkler escutcheon in dairy cooler. Comments: If violations noted during the inspection are not corrected by the given re-inspection date,additional fees are as follows: $100.00-First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections Reports Reports Annual Fire Alarm Comment 9/26/17/API Andrew Shepard Reports Semi-Annual Kitchen hood Fire Suppression for all Hoods Comment Summit 1/3/18 Reports Emergency Egress Exit and Egress Lights Testing. Comment Ken Van heiden 5/1/18 Reports Fire Extinguisher Service Comment Summit 7/17 Reports Comment Inspection Fee $ 600.00 Occupancy Fee $ 10 00 Re-inspection Fee Total Fee* S 610.00 Received By Ken Van Heiden AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload (for long inspections) Reinspection Re-inspection# Date Time 1 6/21/2018