Loading...
HomeMy WebLinkAbout2141 LA PORTE RD \;�`�� INVOICE DATE DUE DATE INVOICE# TOTAL DUE /4.11� , - r„, 05/16/2018 06/20/2018 2018-00000341 $100.00 SIte 110. c?it'rloo Ao Customer#: 6265 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable MOTEL 6 715 Mulberry St 2343 LOGAN AV WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-2141 LA PORTE RD -4-25-18 FOR BILLING INQUIRY: (319)291-4323 L Description ( Total Price INSPECTION 20,000 $90.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 6265 05/16/2018 06/20/2018 2018-00000341 $100.00 Less Prepayment $0.00 Total Due—> $100.00 City of Waterloo Commercial Fire Inspection Report Inspection Number 1419 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 2141 LaPorte Rd Business name Motel 6 Inspection Date* 4/25/2018 Proprietor Andy Patel Business Phone 319-233-9191 Email* m64746bo@6franchise.com Email 2 Property Owner Emergency Contact Andy Patel Information Phone 319-830-3609 Violations Ref# CODE Violation&Location Corrected 1 2015 IFC 1013.6.3 Exit signs shall be illuminated at all times.To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss,the illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or an on-site generator. *Multiple Egress lights were found to be out when tested *Corrective action, repair or replace egress lights found to be out 1)Exit light by the main entrance 2)Exit light in the pool room Ref# CODE Violation &Location Corrected 2 703.2.3 Swinging fire doors shrill close from the full open position and latch automatically. *Multiple doors to rooms were found that do not close and latch at all. It is recommended that maintenance staff check all the doors on premises and ensure that they close and latch properly. Upon reinspection,doors will be check again for proper operation. *Both sets of fire doors serving the elevators on both floors did not fully shut as well. 3 2015 IFC 1008.2 Illumination required.The means of egress serving a room or space shall be illuminated at all times that the room or space is occupied. 2015 IFC 1008.3.4 Duration.The emergency power system shall provide power for a duration of not less than 90 minutes and shall consist of storage batteries, unit equipment or an on-site generator. *Multiple egress light were found not to be working 1) Egress light at the front/main door 2)Egress light in the west stairs 3) Egress light by room 223 4)Egress light in east stairs 5) Egress light in guest laundry/vending room 4 2015 IFC 901.4 Fire protection systems shall be maintained in accordance with the original installation standards for that system. *Multiple doors to rooms and to the main office were out of adjustment as to not provide a complete smoke seal when fully closed.The door to the main office also had an unapproved hold open device attached to the bottom of the door 5 2015 IFC 901.4.5 Appearance of equipment.Any device that has the physical appearance of life safety or fire protection equipment but that does not perform that life safety or fire protection function shall be prohibited. Ref# CODE Violation &Location Corrected 6 2015 IFC 901'.6 Inspection,testing and maintenance. Fire detection, alarm, and extinguishing systems, mechanical smoke exhaust systems,and smoke and heat vents shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected,tested and maintained or removed. 1)The sprinkler system annual check performed by Black Hawk Sprinkler noted multiple deficiencies that were not repaired. Including a 5 year test of the system. 2)The sprinkler piping and heads in the pool mechanical room have excessive corrosion on them. 3)Annual alarm system check is years out of date, need to have a current inspection. 4) Have the alarm inspection personnel review for the requirements of strobe notification in the handicap bathrooms in 127 and 128. 5)Smoke detectors are out in rooms 239, 234, 138,ensure all smoke detectors are in working condition at all times. 6) Fire extinguisher cabinet on 2nd floor is missing the tool to break the glass in case of emergency. 7)Sprinkler head outside of main office has texture on it, sprinkler heads are not to be painted or allowed to accumulate dirt/debris. 8) Box for spare sprinkler heads in sprinkler room needs to be mounted on the wall in the sprinkler room. 9)There is a wire hanging on the sprinkler head in the laundry shoot 10)Missing escushion for sprinkler head in pool bathroom 7 605.3 Maintain 36" path to and around electrical panels *Storage around panels in electrical room 8 2015 IFC 605.1 Abatement of electrical hazards. Identified electrical hazards shall be abated. *Improper wiring/exposed wires on the exhaust fan in the pool mechanical room 9 2015 IFC 605.2 Illumination. Illumination shall be provided for service equipment areas, motor control centers and electrical panel boards. *Provide permanent lighting in sprinkler room, a plug in work light is being used as the light source. 10 605.6 Open junction boxes and open wiring splices shall be prohibited. Approved covers shall be provided for all switch and outlet boxes. *Multiple junction box covers are missing on the 1st floor near rooms 145, 143, 141, 139, 126 *Exposed wiring on light ballasts in the laundry room 11 2015 IFC 509.1 Identification. Fire protection equipment shall be identified in an approved manner. Rooms containing controls for air-conditioning systems, sprinkler risers and valves,or other fire detection,suppression or control elements shall be identified for the use of the fire department.Approved signs required to identify the fire protection equipment and equipment location shall be constructed or durable materials, permanently installed and readily visible. *Install a sign marking the sprinkler riser room Ref# CODE Violation &Location Corrected 12 2015 IFC 703:1 Maintenance.The required fire-resistance rating of fire-resistance-rated construction, including, but not limited to, walls,firestops, shaft enclosures, partitions, smoke barriers,floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems, shall be maintained. *Wiring from security cameras penetrates a fire-rated wall in the east stairway. hole needs to be fire caulked. 13 Provide cleaning/maintenance records for dryer vents, both hotel and guest dryers. Maintenance/cleaning of vents may be performed by hotel staff,dates/times/names/signatures of personnel performing cleaning need to be recorded. 14 Celings need to be patched/repaired in sprinkler room and pool mechanical room. Scuttle hole cover in laundry room,over dryers, needs to be replaced. 15 Final inspection needs to be called in for the water heater,call the building department for a plumbing inspection. 16 Door handle on room 134 needs repair, is about to fall apart Comments: If violations noted during the inspection are not corrected by the given re-inspection date,additional fees are as follows: $100.00-First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections Reports Reports Fire Extinguisher Service Comment Good, performed by Superior Fire Equipment Feb 2018 Reports Annual Fire Sprinkler Comment Not accepted, performed by Black Hawk Sprinkler, numerous deficiencies notated and not fix, 5 year over due Reports Annual Fire Alarm Comment Not accepted,out of date, numerous years since last performed Inspection Fee $ 90.00 Occupancy Fee $ 10.00 Re-inspection Fee $ Total Fee' $ 100.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. •File Upload(for long inspections) Reinspection Re-inspection# Date Time 5/16/2018