Loading...
HomeMy WebLinkAbout1400 MAXHELEN BLVD INVOICE DATE DUE DATE INVOICE# TOTAL DUE /1*.I iI —1 ��into ter;, 05/16/2018 06/20/2018 2018-00000340 $80.00 paitiPP °l'erloo �o Customer#: 22995 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable LANDMARK COMMONS 715 Mulberry St 1400 MAXHELEN BLVD WATERLOO, IA 50703 WATERLOO,IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1400 MAXHELEN BLVD- 5-16-18 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 • CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 22995 05/16/2018 06/20/2018 2018-00000340 $80.00 Less Prepayment $0.00 Total Due — $80.00 City of Waterloo Commercial Fire Inspection Report Inspection Number 1478 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 1400 Maxhelen Blvd Business name Landmark Commons Inspection Date* 5/16/2018 Proprietor Chad Wagner Business Phone 319-231-6735 Email* cwagner@fvrc.com Email 2 Property Owner Friendship Village Emergency Contact Information Phone Violations Ref# CODE Violation &Location Corrected 1 2015 IFC Section 1013 Exit Signs 1013.6.3 Power source. Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss,the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or an on-site generator. *Exit lights were found to be out when tested *Exit light by Model Train Room *Exit light by room 1202 ,Ref# CODE Violation&Location Corrected 2 2015 IFC Fire-Resistance-Rated Construction 703.2 Opening protective. Opening protective shall be maintained in an operative condition in accordance with NFPA 80.Where allowed by the fire code official,the application of field-applied labels associated with the maintenance of opening protective shall follow the requirements of the approved third-party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed, or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. *Provide current inspection for Fire Door in Garage area leading into Woodshop *1st floor Wii Room doors are missing self closing hardware,doors are fire rated *I will check with the Building Official about the doors in the elevator lobby areas on the 2nd and 3rd floor areas of both wings. Doors were found to be propped open, however were not fire rated doors connecting to a corridor. May need self closing hardware with hold- open devices 3 2015 IFC Fire-Resistance-Rated Construction 703.2.3 Door Operation. Swinging fire doors shall close from the full-open position and latch automatically.The door closer shall exert enough force to close and latch the door from any partially open position. *Fire doors were found that do not latch from the fully-open position *Door in Stairway 2 near 1211-1216 split *Door in Stairway 1 2nd floor by 1209 *Door in Stairway 4 1st floor by 1122 *Door in Stairway 6 1st floor door Comments: If violations noted during the inspection are not corrected by the given re-inspection date, additional fees are as follows: $100.00 -First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections Reports Reports Annual Fire Sprinkler Comment Performed 04/13/2018 by Black Hawk Sprinkler Reports Annual Fire Alarm Comment Just performed, by Hawkeye Alarm, email report Reports Semi-Annual Kitchen hood Cleaning for all Hoods Comment Harris Cleaning Reports Semi-Annual Kitchen hood Fire Suppression for all Hoods Comment Superior,just performed, email report Reports Fire Extinguisher Se.-vice Comment 10/2017, Superior Inspection Fee $ 70.00 Occupancy Fee $ 10,00 Re-inspection Fee $ Total Fee* S 80,00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload (for long inspections) Reinspection Re-inspection# Date Time 6/6/2018