Loading...
HomeMy WebLinkAbout610 E 4TH ST INVOICE DATE DUE DATE INVOICE# TOTAL DUE l�i�1F1t 07/06/2018 08/10/2018 2019-00010032 $80.00 k o?terioo Customer#: 23030 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable IA TAUT' 715 Mulberry St 610 E 4TH ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed. DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION - 610 E 4TH ST- 6-15-18 FOR BILLING INQUIRY: (319)291-4323 LDescription I Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 23030 07/06/2018 08/10/2018 2019-00010032 $80.00 Less Prepayment $0.00 Total Due -* $80.00 City of Waterloo Commercial Fire Inspection Report Inspection Number 1573 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock,Weliver@waterloo-ia.org File Upload Address* 610E 4th St Business name IA Tahf Inspection Date* 6/15/2018 (R-91("\WP1) Proprietor Eric Lampe Business Phone 319-234-1411 Email* iatahfl @yahoo.com Email 2 Property Owner Emergency Contact Information Phone Violations Ref# CODE Violation&Location Corrected 1 2015 IFC Section 1008 Means of Egress Illumination 1008.2 Illumination required.The means of egress illumination serving a room or space shall be illuminated at all times that the room or space is occupied. *Egress lights were found to be out when tested -Egress light in the South Stairwell between 6th and 7th floor -Egress light by room 57 #Corrective action, repair or replace egress light Ref# CODE Violation &Location Corrected 2 2015 IFC Section 1013 Exit Signs 1013.6.3 Power source. Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss,the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or an on-site generator. *Exit light was found to be out when tested -Exit light on 4th floor by south stairwell #Corrective action, repair or replace Exit light 3 NFPA 13 Automatic Sprinkler Systems System components and hardware 6.2.8 Sprinklers subject to mechanical injury shall be protected with listed guards. *Sprinkler deflector heads underneath both stairwells are very close to areas being utilized for storage and may be subject to damage. #Corrective action,contact your sprinkler contractor and install guards over these sprinkler head deflectors 4 Please provide annual reports listed below.These reports may be emailed to the email address listed above. *Annual Sprinkler inspection/test *Annual Fire Alarm inspection/test *Dryer exhaust cleaning report Comments: If violations noted during the inspection are not corrected by the given re-inspection date,additional fees are as follows: $100.00-First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections Reports Reports Fire Extinguisher Service Comment Proshield, Sept 2017 Reports Annual Fire Sprinkler Comment Please provide current annual report Reports Annual Fire Alarm Comment Please provide current annual report Reports Comment Dryer exhaust cleaning report. *Maintenance should be conducted according to manufacturer's recommendations Exhaust cleaning and maintenance may be performed by on-site maintenance technicians,document date,time,name and signature of personnel performing the maintenance. Inspection Fee $ 70.00 Occupancy Fee $ 10.00 Re-inspection Fee $ Total Fee* S 80.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload (for long inspections) Reinspection Re-inspection# Date Time 7/6/2018