Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
106 E 3RD ST
INVOICE DATE DUE DATE INVOICE# TOTAL DUE /Il1jl 1\ /I11�■�r�r; 07/06/2018 08/10/2018 2019-00010029 $80.00 iextri Grerloo o Customer#: 13018 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable CEDAR RIVER TOWER 715 Mulberry St 106 E 3RD ST WATERLOO, IA 50703 WATERLOO, IA 50703 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 106 E 3RD ST- 6-25-18 FOR BILLING INQUIRY: (319)291-4323 Description ( Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 13018 07/06/2018 08/10/2018 2019-00010029 $80.00 Less Prepayment $0.00 Total Due--> $80.00 City of Waterloo Commercial Fire Inspection Report Inspection Number 1602 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 106E 3rd St Business name Cedar River Towers Inspection Date* 6/25/2018 Proprietor Christina Campbell Business Phone 319-234-0652 Email* crtleasing©seldin.com Email 2 Property Owner Emergency Contact Information Phone Violations Ref# CODE Violation&Location Corrected 1 2015 IFC Means of Egress Section 1013 Exit Signs 1013.6.3 Power source. Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss,the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or an on-site generator.The installation of the emergency power system shall be in accordance with Section 604. *Exit Signs were found to be out when tested,exit signs include sign by room 603,sign by room 308,sign by room 208 *Corrective action, repair/replace signs Ref# CODE Violation &Location Corrected • 2 2015 IFC Means of Egress Section 1008 Means of Egress Illumination 1008.2 Illumination required.The means of egress serving a room or space shall be illuminated at all times that the room or space is occupied. *Egress lights were found to be out when tested, lights include light by room 608, light by room 302 *Corrective action, repair/replace lights 3 2015 IFC Fire Protection Systems Section 901 General 901.6 Inspection,testing and maintenance. Fire detection,alarm, and extinguishing systems, mechanical smoke exhaust systems, and smoke and heat vents shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected,tested and maintained or removed. *Multiple sprinkler head deflectors were found throughout the building with an excessive build-up of lint&dust on them *Contact your fire sprinkler contractor and determine the best way to clean the deflector heads 4 2015 IFC Fire and Smoke Protection Features Section 703 Fire- Resistance-Rated Construction 703.2.3 Door operation. Swinging fire doors shall close from the full-open position and latch automatically.The door closer shall exert enough force to close and latch the door from any partially open position. *Door in stairway on 6th floor was stuck and would not open initially,then had problems closing fully *Corrective action, repair/adjust door so that it operates correctly Ref# CODE Violation&Location Corrected 5 2015 IFC Fire and Smoke Protection Features Section 703 Fire- Resistance-Rated Construction 703.2 Opening protectives. Opening protectives shall be maintained in an operative condition in accordance with NFPA 80. Where allowed by the fire code official,the application of field- applied labels associated with the maintenance of opening protectives shall follow the requirements of the approved third- party certification organization accredited for listing the opening protective. Fire doors and smoke barrier doors shall not be blocked or obstructed,or otherwise made inoperable. Fusible links shall be replaced promptly whenever fused or damaged. Fire door assemblies shall not be modified. 2015 IFC Fire and Smoke Protection Features Section 703 Fire- Resistance-Rated Construction 703.2.2 Hold-open devices and closers. Hold-open devices and automatic door closers,where provided,shall be maintained. During the period that such device is out of service for repairs,the door it operates shall remain in the closed position. 2013 NFPA 80.A.4.2.1 Labels can be permitted to be of metal, paper,or plastic or can be permitted to be stamped or diecast into the item. Labels should not be removed,defaced,or made illegible while the door is in service. If the label on an existing fire door has been removed or is no longer legible, it is acceptable to verify the rating of the fire door through other means acceptable to the AHJ such as an inspection or certification service that provides acceptable documentation. *Multiple rated fire doors in the building had their rating tags painted over.These tags are not to be altered or removed. *Multiple rated fire doors had unapproved hold-open devices on the bottom of the doors keeping the doors in an open position *Corrective action, remove all unapproved hold-open devices from all rated fire doors in the building and ensure that all tags on fire rated doors are present and legible. If tags are missing and/or are not legible,the rated fire doors shall be certified/inspected by a third party to be confirmed that they meet rating requirements. Ref# CODE Violation&Location Corrected 6 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.3 Working space and clearance.A working space of not less than 30 inches in width, 36 inches in depth and 78 inches in height shall be provided in front of electrical service equipment.Where the electrical service equipment is wider than 30 inches,the working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.3.1 Labeling. Doors into electrical control panel rooms shall be marked with a plainly visible and legible sign stating ELECTRICAL ROOM or similar approved wording.The disconnecting means for each service,feeder or branch circuit originating on a switchboard or panelboard shall be legibly and durably marked to indicate its purpose unless such purpose is clearly evident. *Closet in the first floor common area had storage blocking the electrical panel *Corrective action, remove storage from in front of electrical panel. 7 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.6 Unapproved conditions.Open junction boxes and open- wiring splices shall be prohibited.Approved covers shall be provided for all switch and electrical outlet boxes. *In the pent house,there were open-wiring splices near the stairway door. *Corrective action,fix open-wiring splices Comments: If violations noted during the inspection are not corrected by the given re-inspection date,additional fees are as follows: $100.00-First Re-inspection I$150.00-Second Re-inspection $200-Third and subsequent Re-inspections Reports Reports Annual Fire Sprinkler Comment Please email/provide reports Reports Annual Fire Alarm Comment Please email/provide reports Reports Fire Extinguisher Service Comment Proshield, 5-2018 Reports Annual Generator Service Comment Please email/provide reports Reports Annual Generator Load Test , , , Comment Please email/provide reports Reports Comment **Dryer vent/exhaust cleaning/maintenance should be done in accordance with manufacturer's recommendations. Document the date,time, personnel performing maintenance and signature. Maintenance/cleaning may be done by maintenance/staff personnel. Inspection Fee $ 70.00 Occupancy Fee $ 10.00 Re-inspection Fee $ Total Fee* $ 80.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload(for long inspections) Reinspection Re-inspection# Date Time 7/16/2018