Commercial Fire Inspection Report
• P
Inspection Number 1530
Prior Inspection Fill this field if it is available, it will auto-fill business name and address.
Number
Inspector* Brock Weliver
Waterloo Fire Rescue
425 E 3rd Street Waterloo, IA 50703
Phone(319)883-1615
Email: Brock.Weliver@waterloo-ia.org
File Upload
Address* 105 Broadway St
Business name Heating and Cooling Supply
Inspection Date* 6/7/2018
Proprietor Joel Hoppe
Business Phone 319-215-8376
Email* joelh@heatingcoolingsupply.com
Email 2
Property Owner
Emergency Contact
Information
Phone
Violations
Ref# CODE Violation&Location Corrected
Ref#
CODE Violation &Location Corrected
1 2015 IFC Fire and Smoke Protection Features
Section 701
701.2 Unsafe conditions.Where any components in this chapter
are not maintained and do not function as intended or do not have
the fire resistance required by the code under which the building
was constructed, remodeled or altered,such component(s)or
portion thereof shall be deemed an unsafe condition, in
accordance with Section 110.1.1. Components or portions thereof
determined to be unsafe shall be repaired or replaced to conform
to that code under which the building was constructed, remodeled,
altered or this chapter, as deemed appropriate by the fire code
official.
2015 IFC Fire Protection Systems
Section 901
901.4 Installation. Fire protection systems shall be maintained in
accordance with the original installation standards for that system.
Required systems shall be extended, altered or augmented as
necessary to maintain and continue protection where the building is
altered, remodeled or added to.Alterations to fire protection
systems shall be done in accordance with applicable standards.
*The annual fire sprinkler inspection performed on your system
notated some deficiencies.
-Corrective action, provide documentation that repair work has
been performed by a licensed sprinkler contractor to correct these
deficiencies.
*Ceiling tiles in the drop ceiling in the IT room were found to be
missing. Ceiling tiles/systems are components of fire
detection/suppression systems. Missing tiles allow for smoke and
heat to bypass the sprinkler head or detector and escape into
other areas of the building, rendering the sprinkler or detector
ineffective.
-Corrective action, replace missing ceiling tiles in IT room,
or have a licensed/certified sprinkler contractor properly
reconfigure the sprinkler system in this area for proper coverage .
2 2015 IFC Means of Egress
Section 1013
1013.6.3 Power source. Exit signs shall be illuminated at all times.
To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss,the sign illumination means
shall be connected to an emergency power system provided from
storage batteries, unit equipment or an on-site generator.
*Exit lights were found to be out when tested
-Corrective action, repair or replace exit lights
-Exit light in sprinkler riser room
-Exit light in warehouse office
Comments:
If violations noted during the inspection are not corrected by the given re-inspection date,additional fees
are as follows:
$100.00 -First Re-inspection I$150.00 -Second Re-inspection I$200 -Third and subsequent Re-inspections
Reports
Reports Annual Fire Sprinkler
Comment Continental, had deficiencies notated, not corrected at this time
4-26-2018
Reports Fire Extinguisher Service
Comment Superior
5-2018
Inspection Fee $ 90.00
Occupancy Fee $ 10.00
Re-inspection Fee $
Total Fee* $ 100.00
Received By
AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM.
File Upload (for long
inspections)
Reinspection
Re-inspection# Date Time
6/28/2018