Loading...
HomeMy WebLinkAbout2011 LA PORTE RD ;��. INVOICE DATE DUE DATE INVOICE# TOTAL DUE 111 1 / 1F.\�iga 07/05/2018 fl' i 08/10/2018 2019-00010019 $100.00 eT.4 Customer#: 5002 Please Make Check Payable and Remit To: City of Waterloo A TTN: City Clerk/Accounts Receivable COMFORT INN- WATERLOO 715 Mulberry St PO BOX 9118 WATERLOO, IA 50703 FARGO,ND 58106 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-2011 LA PORTE RD- 6-20-18 FOR BILLING INQUIRY: (319)291-4323 1 L Description I Total Price J INSPECTION 20,000 OCCUPANCY FEE $90.00 $10.00 CUSTOMER# BILLING DATE DUE DATE 5002 INVOICE# CHARGES 07/05/2018 08/10/2018 2019-00010019 $100.00 Less Prepayment $0.00 Total Due $100.00 City of Waterloo Corrirnercial Fire Inspection Report Inspection Number 1588 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 2011 LaPorte Rd Business name Comfort Inn&Suites Inspection Date* 6/20/2018 Proprietor Jim Burbridge Business Phone 319-234-5452 Email* cisia.203@gmail.com Email 2 Property Owner Shri Ekadanta Inc Emergency Contact Information Phone Violations Ref# CODE Violation&Location Corrected CODE Violation &Location Corrected 1 2015 IFC Fire Protection Systems Section 901 General 901.6 Inspection,testing and maintenance. Fire detection, alarm, and extinguishing systems, mechanical smoke exhaust systems, and smoke and heat vents shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected,tested and maintained or removed. *Sprinkler deflector head was found in the laundry room with excessive dust/lint build up. Ensure that all sprinkler deflector heads are kept free of dust/debris/paint which could render the sprinkler system ineffective. *Escutcheon ring around sprinkler deflector head in managers office was found to be lose. Repair/replace escutcheon ring. **Contact your sprinkler system contractor and review the comments noted in the last annual sprinkler report. Provide documentation that any items that need to be addressed have been corrected. 2 Provide the following annual reports: Fire Alarm Test/Inspection Dryer Vent/Exhaust Maintenance report **Dryer vent/exhaust cleaning/maintenance should be done in accordance with manufacturer's recommendations. Document the date,time, personnel performing maintenance and signature. Maintenance/cleaning may be done by hotel personnel. Comments: If violations noted during the inspection are not corrected by the given re-inspection date,additional fees are as follows: $100.00-First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections Reports Reports Annual Fire Sprinkler Comment Black Hawk Sprinkler, 11 -2017 Reports Annual Fire Alarm Comment Provide current annual report Reports Fire Extinguisher Service Comment Proshield, 10-2017 Inspection Fee $ 90.00 Occupancy Fee $ 10.00 Re-inspection Fee $ Total Fee* $ 100.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload(for long inspections) Reinspection Re-inspection# Date Time 7/11/2018