COMMERCIAL INSPECTION- 102 TOWER PARK DR- 7-9-18
FOR BILLING INQUIRY: (319)291-4323
L Description
I Total Price J
INSPECTION 2,000
$70.00
OCCUPANCY FEE
$10.00
(16
`^) ("Ac
CUSTOMER# BILLING DATE DUE DATE
8009 INVOICE# CHARGES
07/10/2018 08/22/2018 2019-00010038 $80.00
Less Prepayment $0.00
Total Due—* $80.00
City of Waterloo
Commercial Fire Inspection Report
Inspection Number 1651
Prior Inspection Fill this field if it is available, it will auto-fill business name and address.
Number
Inspector* Brock Weliver
Waterloo Fire Rescue
425 E 3rd Street Waterloo, IA 50703
Phone(319)883-1615
Email: Brock.Weliver@waterloo-ia.org
File Upload
Address* 1925 LaPorte Rd
Business name Burger King
Inspection Date* 7/12/2018
Proprietor Holly Walther
Business Phone 319-232-6552
Email* holly@rockkinglp.com
Email 2
Property Owner Flynn Jones Partnership
Emergency Contact
Information
Phone
Violations
Ref# CODE Violation &Location Corrected
1 2015 IFC General Requirements Section 315 General Storage
315.3.1 Ceiling clearance. Storage shall be maintained 2 feet or
more below the ceiling in nonsprinklered areas of buildings or not
less than 18 inches below sprinkler head deflectors in sprinklered
areas of buildings.
*Storage in the back storage areas and coolers were found to be
stacked up to the ceiling
**Corrective action, lower storage in all areas of the building
Ref# CODE Violation &Location Corrected
2 2015 IFC Building Services and Systems Section 605 Electrical
Equipment, Wiring and Hazards
605.5 Extension cords. Extension cords and flexible cords shall not
be a substitute for permanent wiring. Extension cords and flexible
cords shall not be affixed to structures.extended through walls,
ceilings or floors, or under doors or floor coverings, nor shall such
cords be subject to environmental damage or physical impact.
Extension cords shall be used only with portable appliances.
*An Extension cord was found to be plugged into a power tap and
ran to a cooler next to the managers office
**Corrective action, extension cords are not to be used as
permanent wiring
3 2015 IFC Building Services and Systems Section 609 Commercial
Kitchen Hoods
Table 609.3.3.1 Commercial Cooking System Inspection Frequency
Type of Cooking Operations
• High-volume cooking operations such as 24-hour
cooking, charbroiling or wok cooking, Frequency of Inspection 3
months
• Low-volume cooking operations such as places of
religious worship, seasonal businesses and senior centers,
Frequency of Inspection 12 months
•Cooking operations utilizing solid fuel-burning
cooking appliances, Frequency of Inspection 1 month
•All other cooking operations, Frequency of Inspection 6 months
4 2015 IFC Fire Protection Systems Section 901 General
901.6 Inspection, testing and maintenance. Fire detection, alarm,
and extinguishing systems, mechanical smoke exhaust systems,
and smoke and heat vents shall be maintained in an operative
condition at all times,and shall be replaced or repaired where
defective. Nonrequired fire protection systems and equipment shall
be inspected, tested and maintained or removed.
*Ceiling tiles were found to be missing in multiple areas of the back
kitchen area
**Corrective action, repair or replace missing ceiling tiles
5 2015 IFC Means of Egress Section 1008 Means of Egress
Illumination
1008.2 Illumination required. The means of egress serving a room
or space shall be illuminated at all times that the room or space is
occupied.
*Multiple egress lights were found to be out when tested
**Corrective action, repair or replace egress lights
6 2015 IFC Means of Egress Section 1013 Exit Signs
1013.6.3 Power source. Exit signs shall be illuminated at all times.
To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss,the sign illumination means
shall be connected to an emergency power system provided from
storage batteries, unit equipment or an on-site generator. The
installation of the emergency power system shall be in accordance
with Section 604.
*Exit light by the emergency exit door in the dinning area,drive
thru side,was found to be out when tested
**Corrective action, repair or replace exit light
Comments:
If violations noted during the inspection are not corrected by the given re-inspection date,additional fees
are as follows:
$100.00-First Re-inspection I$150.00-Secood,Rerinspection I$200-Third and subsequent Re-inspections
Reports
Reports Semi-Annual Kitchen hood Cleaning for all Hoods
Comment Please provide current report, report may be emailed to the email address above
If testing, inspection or servicing is due, please arrange to have it performed
Reports Semi-Annual Kitchen hood Fire Suppression for all Hoods
Comment Please provide current report, report may be emailed to the email address above
If testing, inspection or servicing is due, please arrange to have it performed
Proshield 4-2018
Reports Fire Extinguisher Service
Comment Proshield, 10-2017
Inspection Fee $ 70.00
Occupancy Fee $ 10.00
Re-inspection Fee $
Total Fee* $ 80.00
Received By
AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM.
File Upload (for long
inspections)
Reinspection
Re-inspection# Date
Time
8/2/2018