Loading...
HomeMy WebLinkAbout102 TOWER PARK DR T;��. INVOICE DATE DUE DATE INVOICE# TOTAL DUE A Prksi► � 07/?0/2018, 08/22/2018 2019-000100 3 8 ��,AIS $80.00 �terloo �o Customer#: 8009 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BURGER KING 715 Mulberry St 102 TOWER PARK DR WATERLOO, IA 50703 WATERLOO, IA 50701 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 102 TOWER PARK DR- 7-9-18 FOR BILLING INQUIRY: (319)291-4323 L Description I Total Price J INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 (16 `^) ("Ac CUSTOMER# BILLING DATE DUE DATE 8009 INVOICE# CHARGES 07/10/2018 08/22/2018 2019-00010038 $80.00 Less Prepayment $0.00 Total Due—* $80.00 City of Waterloo Commercial Fire Inspection Report Inspection Number 1651 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 1925 LaPorte Rd Business name Burger King Inspection Date* 7/12/2018 Proprietor Holly Walther Business Phone 319-232-6552 Email* holly@rockkinglp.com Email 2 Property Owner Flynn Jones Partnership Emergency Contact Information Phone Violations Ref# CODE Violation &Location Corrected 1 2015 IFC General Requirements Section 315 General Storage 315.3.1 Ceiling clearance. Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches below sprinkler head deflectors in sprinklered areas of buildings. *Storage in the back storage areas and coolers were found to be stacked up to the ceiling **Corrective action, lower storage in all areas of the building Ref# CODE Violation &Location Corrected 2 2015 IFC Building Services and Systems Section 605 Electrical Equipment, Wiring and Hazards 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures.extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. *An Extension cord was found to be plugged into a power tap and ran to a cooler next to the managers office **Corrective action, extension cords are not to be used as permanent wiring 3 2015 IFC Building Services and Systems Section 609 Commercial Kitchen Hoods Table 609.3.3.1 Commercial Cooking System Inspection Frequency Type of Cooking Operations • High-volume cooking operations such as 24-hour cooking, charbroiling or wok cooking, Frequency of Inspection 3 months • Low-volume cooking operations such as places of religious worship, seasonal businesses and senior centers, Frequency of Inspection 12 months •Cooking operations utilizing solid fuel-burning cooking appliances, Frequency of Inspection 1 month •All other cooking operations, Frequency of Inspection 6 months 4 2015 IFC Fire Protection Systems Section 901 General 901.6 Inspection, testing and maintenance. Fire detection, alarm, and extinguishing systems, mechanical smoke exhaust systems, and smoke and heat vents shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. *Ceiling tiles were found to be missing in multiple areas of the back kitchen area **Corrective action, repair or replace missing ceiling tiles 5 2015 IFC Means of Egress Section 1008 Means of Egress Illumination 1008.2 Illumination required. The means of egress serving a room or space shall be illuminated at all times that the room or space is occupied. *Multiple egress lights were found to be out when tested **Corrective action, repair or replace egress lights 6 2015 IFC Means of Egress Section 1013 Exit Signs 1013.6.3 Power source. Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss,the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or an on-site generator. The installation of the emergency power system shall be in accordance with Section 604. *Exit light by the emergency exit door in the dinning area,drive thru side,was found to be out when tested **Corrective action, repair or replace exit light Comments: If violations noted during the inspection are not corrected by the given re-inspection date,additional fees are as follows: $100.00-First Re-inspection I$150.00-Secood,Rerinspection I$200-Third and subsequent Re-inspections Reports Reports Semi-Annual Kitchen hood Cleaning for all Hoods Comment Please provide current report, report may be emailed to the email address above If testing, inspection or servicing is due, please arrange to have it performed Reports Semi-Annual Kitchen hood Fire Suppression for all Hoods Comment Please provide current report, report may be emailed to the email address above If testing, inspection or servicing is due, please arrange to have it performed Proshield 4-2018 Reports Fire Extinguisher Service Comment Proshield, 10-2017 Inspection Fee $ 70.00 Occupancy Fee $ 10.00 Re-inspection Fee $ Total Fee* $ 80.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload (for long inspections) Reinspection Re-inspection# Date Time 8/2/2018