Loading...
HomeMy WebLinkAbout3658 KIMBALL AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE oripâ– \ r.t. 07/24/2018 07/31/2018 2019-00010053 $80.00 Customer#: 5894 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable MCDONALD'S 715 Mulberry St 2016 HOWARD AV WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-3658 KIMBALL AVE- 7-10-18 FOR BILLING INQUIRY: (319)291-4323 Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 5894 07/24/2018 07/31/2018 2019-00010053 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Commercial Fire Inspection Report Inspection Number 1647 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 3658 Kimball Ave Business name McDonalds Inspection Date* 7/10/2018 Proprietor Michelle Smith Business Phone 319-234-3517 Email* cindy.young@waterloo-ia.org Email 2 Property Owner McDonalds Corporation Emergency Contact Information Phone Violations Ref# CODE Violation&Location Corrected 1 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.3 Working space and clearance.A working space of not less than 30 inches in width,36 inches in depth and 78 inches in height shall be provided in front of electrical service equipment.Where the electrical service equipment is wider than 30 inches,the working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. *Combustible waste material was being temporarily stored in front of electrical panels in the rear of the building **Corrective action, ensure that this area is kept free of storage Ref# CODE Violation&Location Corrected 2 2015 IFC Fire Protection Systems Section 901 General 901.6 Inspection,testing and maintenance. Fire detection,alarm, and extinguishing systems, mechanical smoke exhaust systems, and smoke and heat vents shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected,tested and maintained or removed. *Escutcheon ring of sprinkler deflector head was found to be loose in rear hallway area, by electrical panels **Corrective action, repair/replace escutcheon ring ***Fire Alarm and Fire Sprinkler Systems need current annual inspection/testing, provide current annual reports Comments: If violations noted during the inspection are not corrected by the given re-inspection date,additional fees are as follows: $100.00-First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections Reports Reports Annual Fire Sprinkler Comment Please provide current report, report may be emailed to the email address above **Not current, last performed by Continental 9-19-2014 Reports Annual Fire Alarm Comment Please provide current report, report may be emailed to the email address above **Not current, last performed by Hawkeye Alarm 3-21-2015 Reports Semi-Annual Kitchen hood Cleaning for all Hoods Comment Hoodz,July 2018 Reports Semi-Annual Kitchen hood Fire Suppression for all Hoods Comment Please provide current report, report may be emailed to the email address above Due, last performed July 2017 Reports Fire Extinguisher Service Comment Superior, March 2018 Inspection Fee $ 70.00 Occupancy Fee $ 10.00 Re-inspection Fee $ Total Fee* $ 80.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload (for long inspections) Reinspection Re-inspection# Date Time 7/31/2018