Loading...
HomeMy WebLinkAbout3550 KIMBALL AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE iar\allik 44 09/04/2018 10/10/2018 2019-00010109 $80.00 %rloo ‘o Customer#: 13263 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable L J'S NEIGHBORHOOD GRILL&BAR 715 Mulberry St 3550 KI BALL AV WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-3550 KIMBALL AVE- 8-30-18 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price j INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE `/ DUE DATE INVOICE# CHARGES 13263 09/04/2018 10/10/2018 2019-00010109 $80.00 _ Less Prepayment $0.00 Total Due--> $80.00 City of Waterloo Commercial Fire Inspection Report Inspection Number 1771 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 3550 Kimball Business name LJ's Neighborhood Bar&Grill Inspection Date* 8/30/2018 Proprietor Lyle Pratt Business Phone 319-234-3680 Email* game.time.21@outlook.com Email 2 Property Owner Greg Steelsmith Emergency Contact Greg Steelsmith Information Phone 641-485-5713 Violations Ref# CODE Violation &Location Corrected 1 2015 IFC General Requirements Section 315 General Storage 315.3.1 Ceiling clearance. Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches below sprinkler head deflectors in sprinklered areas of buildings. *Ensure that storage in the building, including in refrigerator and freezer, are kept according to the heights described above Ref# CODE Violation &Location Corrected 2 2015 IFC Building Services and Systems Section 609 Commercial Kitchen Hoods 609.3.4 Extinguishing system service.Automatic fire-extinguishing systems protecting commercial cooking systems shall be serviced as required in Section 904.12.6 2015 IFC Fire Protection Systems Section 904 Alternative Automatic Fire-Extinguishing Systems 904.12.6.2 Extinguishing system service.Automatic fire- extinguishing systems shall be serviced at least every six months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. *Have the extinguishing system on the hoods serviced according to the standards described above. Comments: If violations noted during the inspection are not corrected by the given re-inspection date, additional fees are as follows: $100.00-First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections Reports Reports Semi-Annual Kitchen hood Fire Suppression for all Hoods Comment Please provide current report, report may be emailed to the email address above If testing, inspection or servicing is due, please arrange to have it performed Reports Semi-Annual Kitchen hood Fire Suppression for all Hoods Comment Harris Cleaning, 8-20-2018 Reports Fire Extinguisher Service Comment Superior, 10-2017 Inspection Fee $ 70.00 Occupancy Fee $ 10.00 Re-inspection Fee $ Total Fee* $ 80.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload(for long inspections) Reinspection Re-inspection# Dote Time y/2*/2O18 `