Loading...
HomeMy WebLinkAbout3554 KIMBALL AVE INVOICE DATE DUE DATE INVOICE# TOTAL DUE k1�■,• ter:% 09/04/2018 10/10/2018 2019-00010111 $50.00 �ferloo �o Customer#: 22259 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable ACE HIGH TATTOO LLC 715 Mulberry St 3554 KIMBALL AVE WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION-3554 KIMBALL AVE- 8-30-18 FOR BILLING INQUIRY: (319)291-4323 LDescription Total Price j INSPECTION 1 $40.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 22259 09/04/2018 10/10/2018 2019-00010111 $50.00 Less Prepayment $0.00 Total Due $50.00 City of Waterloo Commercial Fire Inspection Report Inspection Number 1772 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 3554 Kimball Business name Ace High Tattoo Inspection Date* 8/30/2018 Proprietor Kim Martinson Business Phone 319-274-9050 Email* kimtattoos5317@gmail.com Email 2 Property Owner Greg Steelsmith Emergency Contact Information Phone 641-485-5713 Violations Ref# CODE Violation &Location Corrected 1 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.3 Working space and clearance.A working space of not less than 30 inches in width, 36 inches in depth and 78 inches in height shall be provided in front of electrical service equipment. Where the electrical service equipment is wider than 30 inches, the working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. *Maintain the clearances described above around the electrical panel in the equipment room and maintain clearance around the water heater. Ref# CODE Violation &Location Corrected 2 2015 IFC Building Services and Systems Section 605 Electrical Equipment, Wiring and Hazards 605.4.3 Installation. Relocatable power tap cords shall not extend through walls, ceilings,floors, under doors or floor coverings, or be subject to environmental or physical damage. *Ensure that power taps are either laying on the floor are secured to a wall, not hanging by their cords 3 2015 IFC Building Services and Systems Section 605 Electrical Equipment, Wiring and Hazards 605.5 Extension cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors,or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. *Extension cord was being used as permanent wiring in the front waiting area, connected to a TV 4 2015 IFC Fire Protection Systems Section 901 General 901.6 Inspection,testing and maintenance. Fire detection, alarm, and extinguishing systems, mechanical smoke exhaust systems, and smoke and heat vents shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected,tested and maintained or removed. *Have an annual inspection performed on the fire extinguishers Comments: If violations noted during the inspection are not corrected by the given re-inspection date, additional fees are as follows: $100.00-First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections Reports Reports Fire Extinguisher Service Comment Please provide current report, report may be emailed to the email address above If testing, inspection or servicing is due, please arrange to have it performed Inspection Fee $ 40.00 Occupancy Fee $ 10.00 Re-inspection Fee S Total Fee* $ 50.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload (for long inspections) Reinspection Re-inspection# Date Time 9/24/2018