Loading...
HomeMy WebLinkAbout1825 LA PORTE RD (2) INVOICE DATF, DUE DATE INVOICE# TOTAL DUE /1��,��■, kn\ ,r„0 08/13/2018 09/20/2018 2019-00010089 $200.00 °Ierloo ‘° Customer#: 4899 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable SUPER 8 715 Mulberry St 1825 LA PORTE RD WATERLOO, IA 50703 WATERLOO,IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1825 LA PORTE RD- 8-9-18 FOR BILLING INQUIRY: (319)291-4323 L Description Total Price REINSPECTION 3 $200.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 4899 08/13/2018 09/20/2018 2019-00010089 $200.00 Less Prepayment $0.00 Total Due-p $200.00 City of Waterloo RI-INSPECTION - Commercial Fire.Inspection Form Inspection Number 1335 Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 1825 Laporte Rd Business Name Super 8 Inspection Date* 8/9/2018 Proprietor Imdar Lutchmansingh Business Phone 319-229-5574 Email* stay@super8waterloo.com Email 2 Property Owner Emergency Contact Imdar Lutcmansingh Information Phone 1-847-650-7941 Violations Ref# Code Violation &Location Corrected 1 2015 IFC General Requirements Section 315 General Storage 315.3.1 Ceiling clearance. Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches below sprinkler head deflectors in sprinklered areas of buildings. *During re-inspection on 8-9-2018 all storage areas were in compliance. Continue to maintain storage as described above Re"# Code Violation&Location Corrected 2 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.3 Working space and clearance.A working space of not less than 30 inches in width,36 inches in depth and 78 inches in height shall be provided in front of electrical service equipment.Where the electrical service equipment is wider than 30 inches,the working space shall be not less than the width of the equipment. Storage of materials shall not be located within the designated working space. *During re-inspection on 8-9-2018 storage was in compliance as described above.Continue to maintain clearances as described above. 3 2015 IFC Building Services and Systems Section 605 Electrical Equipment,Wiring and Hazards 605.6 Unapproved conditions.Open junction boxes and open-wiring splices shall be prohibited.Approved covers shall be provided for all switch and electrical outlet boxes. *Rooms 315 and 216 were written up on the initial inspection for having exposed wires in the bath fans. These rooms have not been re-inspected since. Ensure that the wiring issues are taken care of and allow for re- inspection. 4 2015 IFC Fire and Smoke Protection Features Section 703 Fire-Resistance-Rated Construction 703.2.3 Door operation. Swinging fire doors shall close from the full-open position and latch automatically.The door closer shall exert enough force to close and latch the door from any partially open position. *During re-inspection on 8-9-2018,the following doors did not self close and latch properly:317, 221,219,217, 205, 203,Along with Fire Doors by 317/stairway and 217 217 also needs hold open device *Previously doors that would not self close and latch were; room by 301,closet by 301, housekeeping by 308, 311, 312, 313, 315, 317,319,323, stair door by 323,2nd floor housekeeping by 208, laundry chute,storage by 223,223,221, 217, 215,211,210, 209, 208,207,206, 203,fire doors by room 101,storage by room 101, 104, 105, 107,elevator equipment room door, 113, 116, 117, fire door by 117, 123. *Ensure that all doors self close and latch properly 5 2015 IFC Fire Protection Systems Section 901 General 901.6 Inspection,testing and maintenance. Fire detection,alarm,and extinguishing systems,mechanical smoke exhaust systems,and smoke and heat vents shall be maintained in an operative condition at all times,and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected,tested and maintained or removed. *During re-inspection on 8-9-2018 smoke detectors were found to be not be working in rooms 219/missing and 205. *Previously smoke detectors in rooms 315,313, 312, 311,219, 218, 217,215,202,201, 118, 115, 111 *Ensure that all smoke detectors are present and in good working condition at all times Comments: *Exit and Egress lights were all in_good working condition on re-inspection on 8-9- 2018 *Holes were patched in owners office *Annual Alarm has been performed If violations noted during the inspection are not corrected by the given re-inspection date,additional fees are as follows: $100,00-First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections Reports Reports Annual Fire Alarm Comment Hawkeye Fire&Alarm,3-7-2018 • Reports Fire Extinguisher Service Comment Proshield, 10-2017 Reports Comment **Dryer vent/exhaust cleaning/maintenance should be done in accordance with manufacturer's recommendations. Document the date,time, personnel performing maintenance and signature. Maintenance/cleaning may be done by maintenance/staff personnel. Inspection Fee $ Occupancy Fee $ Re-inspection Fee $ 200.00 Total Fee* $ 200.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM. File Upload(for long inspections) Reinspection Re-inspection Date Time 8/30/2018