City of Waterloo
Commercial Fire Inspection Report
Inspection Number 1633
Prior Inspection Fill this field if it is available, it will auto-fill business name and address.
Number
Inspector* Brock Weliver
Waterloo Fire Rescue
425 E 3rd Street Waterloo, IA 50703
Phone(319)883-1615
Email: Brock.Weliver@waterloo-ia.org
File Upload
Address* 3032 Ansborough Ave Suite A
Business name Family Video
Inspection Date* 7/9/2018
Proprietor Pete Dudley
Business Phone 319-226-3224
Email* fv0353@fvmc.com
Email 2
Property Owner Family Video Movie Club Inc
Emergency Contact
Information
Phone
Violations
Ref# CODE Violation&Location Corrected
1 2015 IFC General Requirements Section 315 General Storage
315.3.1 Ceiling clearance. Storage shall be maintained 2 feet or
more below the ceiling in nonsprinklered areas of buildings or not
less than 18 inches below sprinkler head deflectors in sprinklered
areas of buildings.
*Storage in back room was found stacked up to the ceiling
**Corrective action, lower storage in back room
Ref# CODE Violation&Location Corrected
2 2015 IFC Building Services and Systems Section 605 Electrical
Equipment,Wiring and Hazards
605.3 Working space and clearance.A working space of not less
than 30 inches in width, 36 inches in depth and 78 inches in height
shall be provided in front of electrical service equipment.Where
the electrical service equipment is wider than 30 inches,the
working space shall be not less than the width of the equipment.
Storage of materials shall not be located within the designated
working space.
"Storage in back room was up against the electrical panels
**Corrective action, maintain clearance around electrical panels
3 2015 IFC Means of Egress Section 1008 Means of Egress
Illumination
1008.2 Illumination required.The means of egress serving a room
or space shall be illuminated at all times that the room or space is
occupied.
2015 IFC Means of Egress Section 1013 Exit Signs
1013.6.3 Power source. Exit signs shall be illuminated at all times.
To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss,the sign illumination means
shall be connected to an emergency power system provided from
storage batteries, unit equipment or an on-site generator. The
installation of the emergency power system shall be in accordance
with Section 604.
*Egress/Exit lights were found to be out when tested. Light by back
door and light by front door
**Corrective action, repair or replace Exit/Egress lights
4 2015 IFC Fire Protection Systems Section 901 General
901.6 Inspection,testing and maintenance. Fire detection, alarm,
and extinguishing systems, mechanical smoke exhaust systems,
and smoke and heat vents shall be maintained in an operative
condition at all times,and shall be replaced or repaired where
defective. Nonrequired fire protection systems and equipment shall
be inspected,tested and maintained or removed.
*Fire Extinguishers are due for yearly inspection/maintenance
**Corrective action, have a licensed contractor perform yearly
service for fire extinguishers
Comments:
If violations noted during the inspection are not corrected by the given re-inspection date,additional fees
are as follows:
$100.00-First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections
Reports
Reports Fire Extinguisher Service
Comment Superior, Past Due, Feb 2017
Inspection Fee $ 40.00
Occupancy Fee $ 10.00
Re-inspection Fee S
Total Fee* S 50,00
Received By
AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM.
File Upload (for long
inspections)
Reinspection
Re-inspection# Date Time
7/30/2018
Commercial Fire Inspection Report
Inspection Number 1649
Prior Inspection Fill this field if it is available, it will auto-fill business name and address.
Number
Inspector* Brock Weliver
Waterloo Fire Rescue
425 E 3rd Street Waterloo, IA 50703
Phone(319)883-1615
Email: Brock.Weliver@waterloo-ia.org
File Upload
Address* 1410 Flammang Dr
Business name Hardee's
Inspection Date* 7/10/2018
Proprietor Cindy Kelchen
Business Phone
Email* cndy@westarfood.com
Email 2
Property Owner 4G Properties LLC
Emergency Contact
Information
Phone
Violations
Ref# CODE Violation &Location Corrected
1 2015 IFC Fire Protection Systems Section 901 General
901.6 Inspection, testing and maintenance. Fire detection, alarm,
and extinguishing systems, mechanical smoke exhaust systems,
and smoke and heat vents shall be maintained in an operative
condition at all times,and shall be replaced or repaired where
defective. Nonrequired fire protection systems and equipment shall
be inspected,tested and maintained or removed.
*K-Guard fire extinguisher in kitchen area needs to be serviced
after use
**Corrective action, contact your fire extinguisher contractor to
have the extinguisher serviced
Ref# CODE Violation &Location Corrected
2 2015 IFC Means of Egress Section 1008 Means of Egress
Illumination
1008.2 Illumination required. The means of egress serving a room
or space shall be illuminated at all times that the room or space is
occupied.
*Egress lights were found to be out when tested, light near cooler
and both lights in the front dinning area
**Corrective action, repair or replace lights
3 2015 IFC Means of Egress Section 1013 Exit Signs
1013.6.3 Power source. Exit signs shall be illuminated at all times.
To ensure continued illumination for a duration of not less than 90
minutes in case of primary power loss,the sign illumination means
shall be connected to an emergency power system provided from
storage batteries, unit equipment or an on-site generator.The
installation of the emergency power system shall be in accordance
with Section 604.
*Exit lights were found to be out when tested, both lights in the
front dinning room area
**Corrective action, repair or replace Exit lights
Comments:
If violations noted during the inspection are not corrected by the given re-inspection date, additional fees
are as follows:
$100.00-First Re-inspection I$150.00-Second Re-inspection I$200-Third and subsequent Re-inspections
Reports
Reports Semi-Annual Kitchen hood Cleaning for all Hoods
Comment Cody's, May 2018
Reports Semi-Annual Kitchen hood Fire Suppression for all Hoods
Comment Please provide current report, report may be emailed to the email address above
Performed by Hawkeye Fire&Safety March 2018
Reports Fire Extinguisher Service
Comment Hawkeye Fire&Safety, March 2018
Inspection Fee $ 70.00
Occupancy Fee $ 10.00
Re-inspection Fee $
Total Fee* $ 80.00
Received By
AN INVOICE OF THIS CHARGE WILL FOLLOW. DO NOT PAY FROM THIS FORM.
File Upload (for long
inspections)
Reinspection
Re-inspection# Date Time
7/31/2018