Loading...
HomeMy WebLinkAbout1925 LA PORTE RD INVOICE DATE DUE DATE INVOICE# TOTAL DUE ����1��',► ��% 07/10/2018 08/22/2018 2019-00010051 $80.00 °ferioo Ao Customer#: 5403 Please Make Check Payable and Remit To: City of Waterloo ATTN: City Clerk/Accounts Receivable BURGER KING 715 Mulberry St 1925 LA PORTE RD WATERLOO, IA 50703 WATERLOO, IA 50702 Amount Enclosed: DETACH AND RETURN TOP PORTION WITH YOUR PAYMENT KEEP THIS PORTION FOR YOUR RECORDS COMMERCIAL INSPECTION- 1925 LA PORTE RD - 7-12-18 FOR BILLING INQUIRY: (319)291-4323 I_Description Total Price INSPECTION 2,000 $70.00 OCCUPANCY FEE $10.00 CUSTOMER# BILLING DATE DUE DATE INVOICE# CHARGES 5403 07/10/2018 08/22/2018 2019-00010051 $80.00 Less Prepayment $0.00 Total Due $80.00 City of Waterloo Commercial Fire Inspection Report Inspection Number 1638 Prior Inspection Fill this field if it is available, it will auto-fill business name and address. Number Inspector* Brock Weliver Waterloo Fire Rescue 425 E 3rd Street Waterloo, IA 50703 Phone(319)883-1615 Email: Brock.Weliver@waterloo-ia.org File Upload Address* 102 Tower Park Dr Business name Burger King Inspection Date* 7/9/2018 Proprietor Dillon Holtzman Business Phone 319-287-4246 Email* todd@rockkinglp.com Email 2 Property Owner Flynn Jones Partnership Emergency Contact Information Phone Violations Ref# CODE Violation &Location Corrected Ref# CODE Violation &Location Corrected 1 2015 IFC Building Services and Systems Section 609 Commercial Kitchen Hoods 609.3.3 Cleaning. Hoods,grease-removal devices,fans, ducts and other appurtenances shall be cleaned at intervals as required by Section 609.3.3.1 through 609.3.3.3 2015 IFC Building Services and Systems Section 609 Commercial Kitchen Hoods 609.3.3.1 Inspection. Hoods, grease-removal devices,fans,ducts, and other appurtenances shall be inspected at intervals specified in Table 609.3.3.1 or as approved by the fire code official. Inspections shall be completed by qualified individuals. 2015 IFC Building Services and Systems Section 609 Commercial Kitchen Hoods 609.3.3.3 Records. Records for inspections shall state the individual and company performing the inspection, a description of the inspection and when the inspection took place. Records for cleaning shall state the individual and company performing the cleaning and when the cleaning took place. Such records shall be completed after each inspection or cleaning and maintained. 2015 IFC Building Services and Systems Section 609 Commercial Kitchen Hoods 609.3.3.3.1 Tags.When a commercial kitchen hood or duct system is inspected, a tag containing the service provider name, address, telephone number and date of service shall be provided in a conspicuous location. Prior tags shall be covered or removed. *please provide current reports for both the Hood Cleaning to be performed bi-annually and the Hood Suppression service report that is supposed to be performed bi-annually 2 2015 IFC Means of Egress Section 1008 Means of Egress Illumination 1008.2 Illumination required.The means of egress serving a room or space shall be illuminated at all times that the room or space is occupied. *Multiple egress lights were found to be out when tested, lights in the kitchen area, lights in the main dining area, lights in the playground area **Corrective action, repair or replace egress lights 3 2015 IFC Means of Egress Section 1013 Exit Signs 1013.6.3 Power source. Exit signs shall be illuminated at all times. To ensure continued illumination for a duration of not less than 90 minutes in case of primary power loss,the sign illumination means shall be connected to an emergency power system provided from storage batteries, unit equipment or an on-site generator.The installation of the emergency power system shall be in accordance with Section 604. *Exit lights were found to be out when tested, light by back door in kitchen and light above main door in dining area Ref# CODE Violation &Location Corrected 4 2015 IFC Fire Serviee Features Section 505 Premises Identification 505.1 Address Identification. New and existing buildings shall be provided with approved address identification.The address identification shall be legible and placed in a position that is visible from the street or road fronting the property.Address identification characters shall contrast with their background.Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not spelled out. Each character shall be not less than 4 inches high with a minimum stroke width of inch.Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response.Where access is by means of a private road and the building cannot be viewed from the public way, a monument, pole or other sign or means shall be used to identify the structure.Address identification shall be maintained. *Address above main door on building is unreadable **Corrective action, repair or replace address 5 2015 IFC General Requirements Section 315 General Storage 315.3.1 Ceiling clearance. Storage shall be maintained 2 feet or more below the ceiling in nonsprinklered areas of buildings or not less than 18 inches below sprinkler head deflectors in sprinklered areas of buildings. *Storage in the kitchen area was found to be stacked up to the ceiling **Corrective action, lower storage Comments: If violations noted during the inspection are not corrected by the given re-inspection date,additional fees are as follows: $100.00-First Re-inspection I$150.00-Second Re-inspection I$200 -Third and subsequent Re-inspections Reports Reports Fire Extinguisher Service Comment Proshield, March 2018 Reports Semi-Annual Kitchen hood Cleaning for all Hoods Comment Please provide current report, report may be emailed to the email address above Reports Semi-Annual Kitchen hood Fire Suppression for all Hoods Comment Please provide current report, report may be emailed to the email address above Inspection Fee $ 70.00 Occupancy Fee $ 10.00 Re-inspection Fee $ Total Fee* $ 80.00 Received By AN INVOICE OF THIS CHARGE WILL FOLLOW..DO NOT PAY FROM THIS FORM. File Upload(for long inspections) Reinspection Re-inspection# Date Time 7/30/2018